MARINA is a 2011 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2010, most recently in April 2026, along with 35 deficiencies and 1 operational control.

Records from 2010 to 2026. Most recent: inspection, 7 April 2026.

Built
2011
Last inspected
7 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9438066 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
969392
Flag
MARSHALL ISLANDS
—
Maury page id
psix-969392

Inspections, by type

…with no type recorded1
Years with a record 14 calendar years (2010–2026)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it29151 - Convention (Subpart B), Net Ton
5216 - Dead Weight, Metric Ton
66084 - Convention (Subpart B), Gross Ton
37193 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

7 April 2026 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8343365
26 November 2025 PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8273670
24 November 2024 COC-CVE Annual
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8036278
5 April 2024 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890348
30 November 2023 PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7829969
29 November 2022 COC-CVE Annual
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7601069
17 January 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7381367
28 November 2021 COC-CVE Annual
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7355815
8 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937083
22 January 2020 Ballast Water Examination · COC-CVE Annual · ISPS Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6894135
1 April 2019 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6653325
6 April 2018 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6388423
5 March 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6468161
17 December 2017 ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6325524
18 January 2017 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6072611
10 February 2016 COC-CVE Annual
Administrative · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 5812448
13 January 2012 COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4223102
10 December 2011 ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4204357
2 February 2011 COC-CVE Initial · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3937791
26 October 2010 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 3871851

Deficiency record · 35

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 November 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power operated watertight doors and those which are normally locked shall not have hold back hooks not subject to central control station release. PSCO observed fire door in galley boundary with a hold back hook not subject to central control station release. 74 SOLAS 09 II-2-9.4.1.1.4 10C
Action required: 10 - Deficiency Rectified
Resolved 26 November 2025
Resolution: Hooks removed and verified by the PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 November 2025 Resolved
Fire extinguishing appliances shall be readily available. PSCO observed access door for portable fire extinguisher and fire hose obstructed by casino equipment. 74SOLAS(2009) II-2/10.1.2
Action required: 10 - Deficiency Rectified
Resolved 26 November 2025
Resolution: Equipment removed to the satisfaction of the PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 November 2024 Resolved
The construction of the doors and door frames in 'A' class dividsions, with the means of securing them when closed, shall provide resistence to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO discovered escape route door in the casino (6.5.2.a) leading to the embarkation area did not fully close.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 November 2024
Resolved 24 November 2024
Resolution: Door was adjusted and witnessed to colse fully by Qualified USCG FPVE
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 November 2024 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. PSCO discovered that over 50% of the life jackets onboard the tenders had deteriorated/ wasted retro-reflective material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 November 2024
Resolved 24 November 2024
Resolution: During exam, crew replaced worn life jackets with spare life jackets in satisfactory condition as witnessed by qualified USCG FPVE
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 30 November 2023 Resolved
Every crew member w/assigned emergency duties shall be familiar w/these duties before the voyage begins. PSCO discovered that stairwell guides were unfamiliar w/basic emergency knowledge during abandon ship drills. Additionally PSCO discovered lifeboat crew member were unfamiliar w/their duties and emergency procedures, to include and not limited to emergency fuel shut off valve location, procedures to engage emergency steering, and location of provisions. 74 SOLAS (20) III/19.2.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 5 April 2024
Resolution: Received Class Report. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 November 2023 Resolved
The construction of doors and door frames in 'A' class divisions, w/the means of securing them when closed, shall provide resistance to fire as well as the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO observed several 'A' class fire doors missing striker plates, and multiple others had frames that were not capable to maintain fire integrity. 74 SOLAS (20) II-2/9.4.1.1.2
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2023
Resolved 5 April 2024
Resolution: Received Class Report. All Sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 November 2023 Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed pallets of garbage obstructing an escape route in the garbage room. Additionally PSCO discovered a steel gangway blocking escape route to tender station in the vicinity of fire screen door 4.3.14. Another escape route leading from the spa staff area into the weight room was blocked by a spin bike. 74 SOLAS (20) II-2/13.1.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 November 2023
Resolved 30 November 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 November 2023 Resolved
Fire doors in main vertial zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movement. PSCO observed fire screen door 12.5.07 closed faster than 10s. Additionally, fire screen door 14.3.01 did not latch properly. 74 SOLAS (20) II-2/9.4.1.1.5.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 November 2023
Resolved 30 November 2023
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 November 2023 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed trash cans blocking the closing of the roller shutter fire door at the grill/fryer in the Terrace Cafe. 74 SOLAS (20) II-2/14.2.1.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 November 2023
Resolved 30 November 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 December 2022 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately re-charged or replaced with an equivalent unit. A sprinkler head above ironing machinery in main laundry Deck 3 port side was found with an empty sprinkler ampule without color or liquid.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2022 Resolved
Doors shall be self-closing. Fire screen door 5.1.08 did not latch and double leaf door 4.2.25 did not latch due to improper sequencing of sequence bar. Deck 15 service door located port aft near the emergency diesel generator had a broken hinge and did not latch.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2022
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 December 2022 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Deck 12 starboard aft art loft emergency exit contained obstacles that blocked the emergency exit. Hand sanitizer station was found in stairway near section valve 7.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 December 2022 Resolved
Fire-fighting systems and applicances shall be kept in good working order and readily available for immediate use. Fire stations on deck 14 port and starboard aft were blocked by stacked lounge chairs.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2022
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 28 November 2021 Resolved
The public address system shall be clearly audible above the ambient noise in all spaces, and shall be provided with an override function controlled from one location on the navigation bridge. PSCO found the casino office on deck 6 did not have a PA system installed in the space. SOLAS 20 III/6.5.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 December 2021
Resolved 17 January 2022
Resolution: Sector Miami recieved attestion from class of the corrected deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 28 November 2021 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergecny source of electrical power. The embarkation light between lifeboats 8 and 10 on the port side was not working. SOLAS 20 III/11
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 28 November 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 November 2021 Resolved
Additional aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situatons. FSD 5.4.13 was improperly marked as an emergency exit but is not designated as an emergecny exit on the ship evacuation plan. SOLAS 20 II-2/13
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 28 November 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 November 2021 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Thumb locks deadbolts were found on FSD 1.4.11 and FSD 2.2.02. SOLAS 20 II-2/13
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 28 November 2021
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 28 November 2021 Resolved
As far as practicable, oil fuel lines shall be arranged far apart from hot surfaces, electrical installations or other sources of ignition and shall be screened or otherwise suitably protected to avoid oil spray of oil leakage onto the sources of ignition. PSCO found supply and return fuel lines on emergency generator missing shielding screens. SOLAS 20 II-2/4.2.2.5.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 28 November 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2019 Resolved
99101 - Other (safety in general) - Escape doors from public spaces that are normally latched shall be fitted with a means of quick release...Quick release mechanisms shall be designed and installed to the satisfaction of the administration and in particular not be equipped with any locking device, set screw or other arrangement that prevents the release of the latch when pressure is applied to the release deice. Various doors in primary and emergency escape routes throughout spa area on deck 14 are equipped with thumb twist locks that prevent the doors from opening when pressure is applied. - 74 SOLAS (2014) II-2 / 13.3.2.6.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 22 January 2020
Resolution: PSCO's reviewed Lloyds report and verified that the locks were removed from the primary escape routes. class report attached.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 January 2017 Resolved
0750- Fire doors in main vertical zone bulkheads shall be self-closing. At least six fire screen doors did not close when tested due to issues with the sequencing bars or door malfunctioning. -74SOLAS(14)II-2/9.4.1.1.5
Due 22 January 2017
Resolved 22 January 2017
Fire Fighting › Means of Escape › Emergency Lighting
Issued 18 January 2017 Resolved
0945- Means of escape shall be marked by lighting or photoluminescent strips at all points of the escape route. Lighting was inoeprable in amidships crew stairwell between decks 10-14. -74SOLAS(14)II-2/13.3.2.5
Due 22 January 2017
Resolved 22 January 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 February 2016 Resolved
The steering gear compartment shall include grating or other nonslip surface to ensure suitable working condition in the event of hydraulic fluid leakage. There is no grating or non-slip surface in steering gear compartment in way of the emergency steering gear ciontrol. 74 SOLAS 04 II-1 / 29.13.2
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 11 February 2016
Resolution: Non skid surface placed in smergency steering deck.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 January 2012 Resolved
0710-Fire doors in main verticle zone bulkheads, galley boundaries and stairway enclosures other than power operated watertight doors... shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Fire screen door 12.3.06 did not close when tested. 74SOLAS (09 cons) II-2/9.4.1.4.1
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 21 January 2012
Resolution: Recieved class report attesting to the adjustment of the door
Fire Fighting › Structural - B Class Divisions › Doors
Issued 13 January 2012 Resolved
0750-The purpose of this regulation is to contain a fire in the space of origin. The following functional requirements shall be met: fire integrity of the divisions shall be maintained at openings and penetrations. B-15 doors in the spa which are meant to be self-closing are wedged open, detracting from the fire resistant integrity of that boundary. 74SOLAS (09 cons) II-2/9.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2012
Resolved 13 January 2012
Resolution: Wedges were removed from doors.
Fire Fighting › Means of Escape › Stairways
Issued 13 January 2012 Resolved
0960-Furniture in stairway enclosures shall be limited to seating.. and shall not restrict the passenger escape route. The aft passenger staircase on deck 12 had a display table that added to the fire risk in the stairway enclosure and detracts from the passengers ease of escape. 74SOLAS (09 cons) II-2/5.3.3
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2012
Resolved 13 January 2012
Resolution: Display table was removed from stairway.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 13 January 2012 Resolved
0700-Ships of all types shall bew subdivided into spaces by thermal and structural divisions having regard to the fire risk of that space. A category 13 space (deck 3 Forward Hotel Storage) is being used as a category 8 space. 74SOLAS (09 cons) II-2/9.2.1
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 21 January 2012
Resolution: The desk in the hotel store was replaced with a metal table. The chair and computer workstation were relocated to storage locker on deck 3 (between frame 44 and 52) that was recategorized from 13 to 7.
Operations/Management › Drills/Instruction › Fire
Issued 13 January 2012 Resolved
2020-The company should clearly define and document the master's responsibility with regard to: verifying that specified requirements are observed. Fire drill was not conducted in accordance with safety management procedures. 74SOLAS (09 cons) IX/3.1; ISM Code 5.1.4
Action required: 705 - Other - as specified
Due 20 January 2012
Resolved 21 January 2012
Resolution: Received class report.
Fire Fighting › Structural - B Class Divisions › Cabin Doors
Issued 10 December 2011 Resolved
0710-Fire Prevention-Cabin Doors in "B" class divisions shall be self closing type. Hold backs are not permitted. Found at least 02 passenger cabin "B" doors that were being held open by the installed carpet in space. Solas (09 CONS) II-2 Reg 9.4.1.2.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2011
Resolved 10 December 2011
Resolution: Doors were adjusted allowing them to clear the carpet, allowing proper operation.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 December 2011 Resolved
0710 Fire Prevention-"A" Class division openings shall be provided with permanently attached means of closing. Jacques restaurant fire doors have door stops installed which prevents doors from closing. This pertains to fire doors separating restaurant from passenger corridor. Solas (09 CONS) II-2 Reg 9.4.1.1.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2011
Resolved 10 December 2011
Resolution: Door stops released allowing the doors to self close.
Fire Fighting › Means of Escape › Stairways
Issued 10 December 2011 Resolved
0750 Fire prevention- Furniture in Stairway enclosures shall be fixed, limited to six seats on each deck, of restricted fire risk and shall not restrict passenger escape routes. Found several tables and chairs in crew center stairway on decks 13 and 14. Solas (09 CONS) II-2 Reg 5.3.3
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 11 December 2011
Resolved 30 December 2011
Resolution: Received e-mail from captain attesting to the removal of the excess furniture within the stairway enclosure.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 10 December 2011 Resolved
0750 Fire Prevention-Where the contents and the use of a space are such as there is doubt as to its classification it shall be treated as a space within the relevant category having the most stringent requirement. Found offices set up in BOSN stores (CAT 13) and the fan room across from cabin 10049 on Deck 10, containing combustible material as well. 74 SOLAS (09 cons) II-2 REG 9.2.2.3.2.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 December 2011
Resolved 30 December 2011
Resolution: Received e-mail from captain attesting to the removal of office furniture within the BOSN store and fan room. Also removed combustible material from fan room.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 10 December 2011 Resolved
0750 Fire Prevention-Where the contents and the use of a space are such as there is doubt as to its classification it shall be treated as a space within the relevant category having the most stringent requirement. Found flammable locker in Spa store on deck 14 containing more than daily use flammable liquids.74 SOLAS (09 cons) II-2 REG 9.2.2.3.2.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 December 2011
Resolved 30 December 2011
Resolution: Received e-mail from captain of vessel attesting to the removal of more than "daily use" of flammable liquids within the Spa.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 4 February 2011 Resolved
Where necessary, non-conductive matting or gratings shall be provided at the front and rear of the switchboard. Non-conductive matting is missing in the stren thruster room and at the fin stabilizer control panels.
Condition: Placed in Improper Service
Due 4 March 2011
Resolved 22 February 2011
Resolution: Non-conducting mat is required at main and emergency switchboard by SOLAS Ch II-1, 45.2 and BV Rules Pt C, Ch 2, Sec 12, 6.1.6. Therefore they are not mandatory to provide them at stern thruster panels & fin stabilizer panels per Class & Administration
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 4 February 2011 Resolved
The safety Management System shall be maintained in accordance with the provisions of the code. Passenger cabin evacuation during ships drills were found to be inconsistent with ship's procedures. Evacuation cards were found in all doors however doors on Port side aft deck 10 were found shut with dead bolts open preventing fire integrity of a B-15 door.
Due 4 March 2011
Resolved 22 February 2011
Resolution: Company has addressed this issue via SMS & has determined that the deadbolt shall not be used to hold any door open. Each cabin attendant shall only wedge opne doors in the imediate area & shall close all doors if he/she leaves the section.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 2 February 2011 Resolved
Waste recepacles shall be constructed of non-combustable materials with no openings in the sides or bottom. Plastic trash cans used for paper adn plastic waste were found in main galley and numerous spaces throughout ship.
Due 4 March 2011
Resolved 30 March 2011
Resolution: Plastic trash can were replaced with metal receptacles. Also see attached e-mail request for metal trash cans.