Records from 2017 to 2025. Most recent: inspection, 29 December 2025.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 December 2025
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and betweens such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Double glass B-15 doors in the Observation Library, doors in the crew lounge, crew gym, crew galley and hotel store manager office were unable to self close.
74SOLAS(2020)
II-2/9.4.1.1.1
17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 December 2025
Resolved
Means shall be provided to control leaks of flammable
liquids. PSCO observed multiple oil catch cans containing
oil in the engine room, multiple gallons of viscous oily water in the deck plates below the shaft and oily water accumulation in the aft purifier room.
74 SOLAS 20 I1-2/4.1.1
17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 December 2025
Resolved
Structural fire protection, including fire-resisting divisions,and protection of openings and penetrations in these divisions, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed a
successful test of the pool grill rolling shutters manual operation however emergency shutdown was inoperable.
74 SOLAS 20 1-2/14.2.1.1.1
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 December 2025
No resolution recorded
Every Fire damper must be fitted with a visible indicator
showing whether it is in the open or closed position. PSCO
observed multiple damper indicator lights were inoperable.
74 SOLAS 20 II-2/9.7.3.1
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 December 2025
Resolved
Each life buoy shall be marked in block capitals of the Roman
alphabet with the name and port of registry of the ship. PSCO
observed portside quick release life bouy without markings.
74 SOLAS 20 II-2/7.1.4
10c
Action required: 10 - Deficiency Rectified
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 December 2025
Resolved
Fire protection systems and fire-fighting systems and
appliances shall be maintained ready for use. PSCO
observed a podium and furniture stored blocking a fire
hydrant on Deck 3.
74 SOLAS 20 II-2/14.1.1
10c
Action required: 10 - Deficiency Rectified
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 December 2025
Resolved
The following functional requirements shall be met: escape
routes shall be maintained in a safe condition, clear of
obstacles. PSCO observed storage of sand bags in the E/R
and quarter passage way blocking the means of escape.
74 SOLAS 20 I-2/13.1.2
10c
Action required: 10 - Deficiency Rectified
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 December 2025
Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such
spaces are classified according to their fire risk as shown in categories (1) to (14). PSCO observed cardboard boxes in
the A/C room N12.2, battery room and radar room on deck
12.
74 SOLAS 20 I1-2/9.2.2.3.2.2
10c
Action required: 10 - Deficiency Rectified
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 December 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed a smoke detector in the electrical workshop covered with a plastic cover inhibiting its ability to function as designed.
SOLAS 20 II-2/14.2.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 9 December 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 March 2019
Resolved
A passenger ship shall be subject to renewal survey including an inspection of the structure and other equipment is in satisfactory condition and fir for service and complies with laws, decrees, orders, and regulations promulgating as a result thereof by the Administration. Vessel's Passenger Ship [name withheld] indicates a subdivision load line assignment marking of C1 is required, however, vessel's hull marking is P1. SOLAS(14) CH I/REG 7(b)(ii).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2019
Resolved 15 April 2019
Resolution: RINA reissued the certificate to reflect the required marking as P1.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 30 March 2019
Resolved
The International Load Line Certificate shall not be delivered to the ship until the surveyor has certified that the marks are correctly and perminently indicated on ships sides. ILLC indicates a marking of C1 is required, however, vessel's hull marking is P1. ICLL A88 REG 9
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2019
Resolved 15 April 2019
Resolution: RINA reissued the certificate to reflect the required marking as P1.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 March 2019
Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck. There is a Room-In-Room construction as per MSC Guidelines SOLAS/25 in the Maitre'D Office located in Atlantic Restaurant. SOLAS (14) II-2/REG 13.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2019
Resolved 9 December 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2018
Resolved
0750- Fire Prevention- 16c
Within the perimeter of stairways enclosures in the accomodation and service spaces only public toilets,lockers of non-combustable material providing storage for non-hazerdous safety equipment and open information counters are permitted. None secure couches and a ping-pong table observed in deck 10 stairway enclosure.
74 SOLAS(2014) II-2/13.3.3.2.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2018
Resolved 27 September 2018
Resolution: Ship removed un-fixed items
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 September 2018
Resolved
0730- Appliances (General Equipment)- 50ac
Lobbies used to seperate an enclosed stairway from galleys may not have direct access to the stairway provided they contain a fire hose station. the lobby between the stairway and the galley on deck 8 does not contain a fire hose station.
74 SOLAS (2014) II-2/13.3.2.3
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2018
Resolution: Fire hydrant station installed on Deck 8 / Staricase 7 in lobby outside galley
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 September 2018
Resolved
0599- Other (Working Spaces)- 16c
Means of escape shall be marked by lighting of
photolumenescent strip indicators placed not more than 300mm above the deck at all points of the escape route.
There were no escape route indicators in the deck 8 aft galley, deck 8 dining area, and the deck 5 lobby.
74 SOLAS (2014) II-2/13.3.2.5.1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2018
Resolution: Escape signs added in appropriate locations throughout the spaces
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 September 2018
Resolved
0750- Fire Prevention- 16c
Penetrations in class A divisions shall be tested in accordance with the fire test procedures code. Wire penetrations above door 8.12 were not properly sealed in accoradance with structural fire protection requirements.
74 SOLAS (2014) II-2/9.3.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2018
Resolution: Penetration filled with approved material
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 4 January 2017
Resolved
Insulation surfaces protected against oil penetration in spaces where penetration of oil products is possible. The surface of insulation shall be impervious to oil or oil vapors. The insulation around fuel oil purifier #4 was found to be saturated in fuel oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 4 January 2017
Resolution: Replaced insulation.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 January 2017
Resolved
Each power-operated sliding watertight door shall be provided with an individual hand operated mechanism. It shall be possible to open and close the door by hand at the door itself from either side, and in addition, close the door from an accessible position above the bulkhead deck with an all round crank motion or some other movement providing the same degree of safety acceptable to the admin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 4 January 2017
Resolution: Hand crank generator was replaced and provided proper movement of the door.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 4 January 2017
Resolved
The approx. time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movemnet with the ship in the upright position. Fire doors were found to close too quickly and dind't sequence properly. FD04.9.14, A60.9.04, A60.8.10, A60.8.16, A60.6.06, A60.6.10, A60.5.21, A60.11.03, A0.2.33, A60.5.21, A60.6.12.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 20 March 2017
Resolution: Door timing was adjusted to close within time alloted to satisfaction of atending CG examiner
Fire Fighting › Structural - B Class Divisions › Corridors
Issued 4 January 2017
Resolved
Continuous "B" class ceilings or linings, in association with the relevant decks or bulkheads, may be accepted as contributing, wholly or in part, to the required insulation and integrity of a division. Provide certificates to prove fiber board material meets requirements for class "B" linings. State rooms adjoining cat 2 stair fwd decks 10, 9, 8, 7, 6 passenger stairs (P/S)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 21 March 2017
Resolution: Vessel provided documentation attesting to lining material meeting requirements for proper fire boundary.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 4 January 2017
Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the division. B15 doors from Corridor ro Panorama Lounge (Deck 9) and forward to Observation Lounge Bar (Deck 11) were found to be unable to close and must remain closed at all times.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 4 January 2017
Resolution: Doors were adjusted and closed properly after.
Fire Fighting › Means of Escape › Corridors
Issued 4 January 2017
Resolved
Safe escape routes shall be provided. Deck 5 Offices adjoining Main Lobby do not escape to a Corridor (room in room arrangement)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 20 March 2017
Resolution: Audible fire alarm placed inside room within a room arrangement to the satisfaction of RO and attending CG examiner.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 January 2017
Resolved
Fire integrity of bulkheads and decks in ships carrying more than 36 passengers. Insulation missing in Electrical Locker deck 11. Additionally, cover plate found missing in emergency escape trunk behind FD-A0.3.87
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 21 March 2017
Resolution: Insulation was replaced in missing areas to the satisfaction of RO and attending CG examiner
Personnel › Training › Passenger Safety
Issued 4 January 2017
Resolved
Every crew member assigned emergency duties shall be familiar with these duties before the voyage begins. Stairway guides knowledge and abilities were not consistently demonstrated. Fire teams did not follow shipboard procedures during demonstration of fire drill. Ship unable to account for all personnel missing during drills either excused or otherwise.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 20 March 2017
Resolution: Fire and abandon ship drill were conducted and crew performance and knowledge was found satisfactory.