SILVER SPIRIT

SILVER SPIRIT is a 2009 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2017, most recently in December 2025, along with 24 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2017 to 2025. Most recent: inspection, 29 December 2025.

Built
2009
Last inspected
29 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9437866
969401
Flag
BAHAMAS, THE
Maury page id
psix-969401

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
…past their stated due date1
Years with a record 5 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4000 - Dead Weight, Metric Ton
39444 - Convention (Subpart B), Gross Ton
13730 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 12

29 December 2025 PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8287249
26 December 2025 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8287354
9 December 2021 COC-CVE Annual · Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7365087
26 October 2021 Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7340020
15 April 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6667804
30 March 2019 COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6648514
27 November 2018 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6592769
29 October 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6570386
19 September 2018 Deficiency Check · ISPS II Exam · Ballast Water Examination · In-Service Inspection · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6544280
9 March 2018 Construction Oversight · COC-CVE Initial Prep
Physical examination · Activities Europe · Activity 6369182
20 March 2017 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6107746
4 January 2017 ISPS II Exam · Ballast Water Examination · In-Service Inspection · COC-CVE Annual
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6066511

Deficiency record · 24

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 December 2025 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and betweens such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Double glass B-15 doors in the Observation Library, doors in the crew lounge, crew gym, crew galley and hotel store manager office were unable to self close. 74SOLAS(2020) II-2/9.4.1.1.1 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 December 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed multiple oil catch cans containing oil in the engine room, multiple gallons of viscous oily water in the deck plates below the shaft and oily water accumulation in the aft purifier room. 74 SOLAS 20 I1-2/4.1.1 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 December 2025 Resolved
Structural fire protection, including fire-resisting divisions,and protection of openings and penetrations in these divisions, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed a successful test of the pool grill rolling shutters manual operation however emergency shutdown was inoperable. 74 SOLAS 20 1-2/14.2.1.1.1 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 December 2025 No resolution recorded
Every Fire damper must be fitted with a visible indicator showing whether it is in the open or closed position. PSCO observed multiple damper indicator lights were inoperable. 74 SOLAS 20 II-2/9.7.3.1 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 December 2025 Resolved
Each life buoy shall be marked in block capitals of the Roman alphabet with the name and port of registry of the ship. PSCO observed portside quick release life bouy without markings. 74 SOLAS 20 II-2/7.1.4 10c
Action required: 10 - Deficiency Rectified
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 December 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed a podium and furniture stored blocking a fire hydrant on Deck 3. 74 SOLAS 20 II-2/14.1.1 10c
Action required: 10 - Deficiency Rectified
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 December 2025 Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed storage of sand bags in the E/R and quarter passage way blocking the means of escape. 74 SOLAS 20 I-2/13.1.2 10c
Action required: 10 - Deficiency Rectified
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 December 2025 Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14). PSCO observed cardboard boxes in the A/C room N12.2, battery room and radar room on deck 12. 74 SOLAS 20 I1-2/9.2.2.3.2.2 10c
Action required: 10 - Deficiency Rectified
Resolved 29 December 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 December 2021 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed a smoke detector in the electrical workshop covered with a plastic cover inhibiting its ability to function as designed. SOLAS 20 II-2/14.2.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 9 December 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 March 2019 Resolved
A passenger ship shall be subject to renewal survey including an inspection of the structure and other equipment is in satisfactory condition and fir for service and complies with laws, decrees, orders, and regulations promulgating as a result thereof by the Administration. Vessel's Passenger Ship [name withheld] indicates a subdivision load line assignment marking of C1 is required, however, vessel's hull marking is P1. SOLAS(14) CH I/REG 7(b)(ii).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2019
Resolved 15 April 2019
Resolution: RINA reissued the certificate to reflect the required marking as P1.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 30 March 2019 Resolved
The International Load Line Certificate shall not be delivered to the ship until the surveyor has certified that the marks are correctly and perminently indicated on ships sides. ILLC indicates a marking of C1 is required, however, vessel's hull marking is P1. ICLL A88 REG 9
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2019
Resolved 15 April 2019
Resolution: RINA reissued the certificate to reflect the required marking as P1.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 March 2019 Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck. There is a Room-In-Room construction as per MSC Guidelines SOLAS/25 in the Maitre'D Office located in Atlantic Restaurant. SOLAS (14) II-2/REG 13.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2019
Resolved 9 December 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2018 Resolved
0750- Fire Prevention- 16c Within the perimeter of stairways enclosures in the accomodation and service spaces only public toilets,lockers of non-combustable material providing storage for non-hazerdous safety equipment and open information counters are permitted. None secure couches and a ping-pong table observed in deck 10 stairway enclosure. 74 SOLAS(2014) II-2/13.3.3.2.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2018
Resolved 27 September 2018
Resolution: Ship removed un-fixed items
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 September 2018 Resolved
0730- Appliances (General Equipment)- 50ac Lobbies used to seperate an enclosed stairway from galleys may not have direct access to the stairway provided they contain a fire hose station. the lobby between the stairway and the galley on deck 8 does not contain a fire hose station. 74 SOLAS (2014) II-2/13.3.2.3
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2018
Resolution: Fire hydrant station installed on Deck 8 / Staricase 7 in lobby outside galley
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 September 2018 Resolved
0599- Other (Working Spaces)- 16c Means of escape shall be marked by lighting of photolumenescent strip indicators placed not more than 300mm above the deck at all points of the escape route. There were no escape route indicators in the deck 8 aft galley, deck 8 dining area, and the deck 5 lobby. 74 SOLAS (2014) II-2/13.3.2.5.1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2018
Resolution: Escape signs added in appropriate locations throughout the spaces
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 September 2018 Resolved
0750- Fire Prevention- 16c Penetrations in class A divisions shall be tested in accordance with the fire test procedures code. Wire penetrations above door 8.12 were not properly sealed in accoradance with structural fire protection requirements. 74 SOLAS (2014) II-2/9.3.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2018
Resolution: Penetration filled with approved material
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 4 January 2017 Resolved
Insulation surfaces protected against oil penetration in spaces where penetration of oil products is possible. The surface of insulation shall be impervious to oil or oil vapors. The insulation around fuel oil purifier #4 was found to be saturated in fuel oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 4 January 2017
Resolution: Replaced insulation.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 January 2017 Resolved
Each power-operated sliding watertight door shall be provided with an individual hand operated mechanism. It shall be possible to open and close the door by hand at the door itself from either side, and in addition, close the door from an accessible position above the bulkhead deck with an all round crank motion or some other movement providing the same degree of safety acceptable to the admin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 4 January 2017
Resolution: Hand crank generator was replaced and provided proper movement of the door.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 4 January 2017 Resolved
The approx. time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movemnet with the ship in the upright position. Fire doors were found to close too quickly and dind't sequence properly. FD04.9.14, A60.9.04, A60.8.10, A60.8.16, A60.6.06, A60.6.10, A60.5.21, A60.11.03, A0.2.33, A60.5.21, A60.6.12.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 20 March 2017
Resolution: Door timing was adjusted to close within time alloted to satisfaction of atending CG examiner
Fire Fighting › Structural - B Class Divisions › Corridors
Issued 4 January 2017 Resolved
Continuous "B" class ceilings or linings, in association with the relevant decks or bulkheads, may be accepted as contributing, wholly or in part, to the required insulation and integrity of a division. Provide certificates to prove fiber board material meets requirements for class "B" linings. State rooms adjoining cat 2 stair fwd decks 10, 9, 8, 7, 6 passenger stairs (P/S)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 21 March 2017
Resolution: Vessel provided documentation attesting to lining material meeting requirements for proper fire boundary.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 4 January 2017 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the division. B15 doors from Corridor ro Panorama Lounge (Deck 9) and forward to Observation Lounge Bar (Deck 11) were found to be unable to close and must remain closed at all times.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 4 January 2017
Resolution: Doors were adjusted and closed properly after.
Fire Fighting › Means of Escape › Corridors
Issued 4 January 2017 Resolved
Safe escape routes shall be provided. Deck 5 Offices adjoining Main Lobby do not escape to a Corridor (room in room arrangement)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 20 March 2017
Resolution: Audible fire alarm placed inside room within a room arrangement to the satisfaction of RO and attending CG examiner.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 January 2017 Resolved
Fire integrity of bulkheads and decks in ships carrying more than 36 passengers. Insulation missing in Electrical Locker deck 11. Additionally, cover plate found missing in emergency escape trunk behind FD-A0.3.87
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 21 March 2017
Resolution: Insulation was replaced in missing areas to the satisfaction of RO and attending CG examiner
Personnel › Training › Passenger Safety
Issued 4 January 2017 Resolved
Every crew member assigned emergency duties shall be familiar with these duties before the voyage begins. Stairway guides knowledge and abilities were not consistently demonstrated. Fire teams did not follow shipboard procedures during demonstration of fire drill. Ship unable to account for all personnel missing during drills either excused or otherwise.
Action required: 705 - Other - as specified
Due 4 February 2017
Resolved 20 March 2017
Resolution: Fire and abandon ship drill were conducted and crew performance and knowledge was found satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.