SILVER SPIRIT
SILVER SPIRIT is a 2009 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2010, most recently in December 2025, along with 41 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 2010 to 2025. Most recent: inspection, 29 December 2025.
- Built
- 2009
- Last inspected
- 29 December 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 41 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9437866 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6XU6
969401
Flag
BAHAMAS, THE
—
Maury page id
psix-969401
Inspections, by type
…with no type recorded2
…past their stated due date1
Years with a record
9 calendar years (2010–2025)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it4000 - Dead Weight, Metric Ton
39444 - Convention (Subpart B), Gross Ton
13730 - Convention (Subpart B), Net Ton
39444 - Convention (Subpart B), Gross Ton
13730 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
29 December 2025
PSC A · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8287249
26 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8287354
9 December 2021
COC-CVE Annual · Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7365087
26 October 2021
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7340020
15 April 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6667804
30 March 2019
COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6648514
27 November 2018
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6592769
29 October 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6570386
19 September 2018
Deficiency Check · ISPS II Exam · Ballast Water Examination · In-Service Inspection · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6544280
9 March 2018
Construction Oversight · COC-CVE Initial Prep
Physical examination · Activities Europe · Activity 6369182
20 March 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6107746
4 January 2017
ISPS II Exam · Ballast Water Examination · In-Service Inspection · COC-CVE Annual
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6066511
23 November 2015
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5768640
27 March 2014
Spot Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4823935
17 January 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3927941
16 December 2010
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3911788
22 November 2010
COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3894727
5 February 2010
ISPS II Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3676027
Deficiency record · 41
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 December 2025
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and betweens such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Double glass B-15 doors in the Observation Library, doors in the crew lounge, crew gym, crew galley and hotel store manager office were unable to self close.
74SOLAS(2020)
II-2/9.4.1.1.1
17C
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 December 2025
Resolved
Means shall be provided to control leaks of flammable
liquids. PSCO observed multiple oil catch cans containing
oil in the engine room, multiple gallons of viscous oily water in the deck plates below the shaft and oily water accumulation in the aft purifier room.
74 SOLAS 20 I1-2/4.1.1
17c
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 December 2025
Resolved
Structural fire protection, including fire-resisting divisions,and protection of openings and penetrations in these divisions, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed a
successful test of the pool grill rolling shutters manual operation however emergency shutdown was inoperable.
74 SOLAS 20 1-2/14.2.1.1.1
16c
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 29 December 2025
No resolution recorded
Every Fire damper must be fitted with a visible indicator
showing whether it is in the open or closed position. PSCO
observed multiple damper indicator lights were inoperable.
74 SOLAS 20 II-2/9.7.3.1
16c
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 December 2025
Resolved
Each life buoy shall be marked in block capitals of the Roman
alphabet with the name and port of registry of the ship. PSCO
observed portside quick release life bouy without markings.
74 SOLAS 20 II-2/7.1.4
10c
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 December 2025
Resolved
Fire protection systems and fire-fighting systems and
appliances shall be maintained ready for use. PSCO
observed a podium and furniture stored blocking a fire
hydrant on Deck 3.
74 SOLAS 20 II-2/14.1.1
10c
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 December 2025
Resolved
The following functional requirements shall be met: escape
routes shall be maintained in a safe condition, clear of
obstacles. PSCO observed storage of sand bags in the E/R
and quarter passage way blocking the means of escape.
74 SOLAS 20 I-2/13.1.2
10c
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 December 2025
Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such
spaces are classified according to their fire risk as shown in categories (1) to (14). PSCO observed cardboard boxes in
the A/C room N12.2, battery room and radar room on deck
12.
74 SOLAS 20 I1-2/9.2.2.3.2.2
10c
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 December 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCO observed a smoke detector in the electrical workshop covered with a plastic cover inhibiting its ability to function as designed.
SOLAS 20 II-2/14.2.1.1.2
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 30 March 2019
Resolved
A passenger ship shall be subject to renewal survey including an inspection of the structure and other equipment is in satisfactory condition and fir for service and complies with laws, decrees, orders, and regulations promulgating as a result thereof by the Administration. Vessel's Passenger Ship [name withheld] indicates a subdivision load line assignment marking of C1 is required, however, vessel's hull marking is P1. SOLAS(14) CH I/REG 7(b)(ii).
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 30 March 2019
Resolved
The International Load Line Certificate shall not be delivered to the ship until the surveyor has certified that the marks are correctly and perminently indicated on ships sides. ILLC indicates a marking of C1 is required, however, vessel's hull marking is P1. ICLL A88 REG 9
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 March 2019
Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck. There is a Room-In-Room construction as per MSC Guidelines SOLAS/25 in the Maitre'D Office located in Atlantic Restaurant. SOLAS (14) II-2/REG 13.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2018
Resolved
0750- Fire Prevention- 16c
Within the perimeter of stairways enclosures in the accomodation and service spaces only public toilets,lockers of non-combustable material providing storage for non-hazerdous safety equipment and open information counters are permitted. None secure couches and a ping-pong table observed in deck 10 stairway enclosure.
74 SOLAS(2014) II-2/13.3.3.2.3
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 September 2018
Resolved
0730- Appliances (General Equipment)- 50ac
Lobbies used to seperate an enclosed stairway from galleys may not have direct access to the stairway provided they contain a fire hose station. the lobby between the stairway and the galley on deck 8 does not contain a fire hose station.
74 SOLAS (2014) II-2/13.3.2.3
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 September 2018
Resolved
0599- Other (Working Spaces)- 16c
Means of escape shall be marked by lighting of
photolumenescent strip indicators placed not more than 300mm above the deck at all points of the escape route.
There were no escape route indicators in the deck 8 aft galley, deck 8 dining area, and the deck 5 lobby.
74 SOLAS (2014) II-2/13.3.2.5.1
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 September 2018
Resolved
0750- Fire Prevention- 16c
Penetrations in class A divisions shall be tested in accordance with the fire test procedures code. Wire penetrations above door 8.12 were not properly sealed in accoradance with structural fire protection requirements.
74 SOLAS (2014) II-2/9.3.1
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 4 January 2017
Resolved
Insulation surfaces protected against oil penetration in spaces where penetration of oil products is possible. The surface of insulation shall be impervious to oil or oil vapors. The insulation around fuel oil purifier #4 was found to be saturated in fuel oil.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 January 2017
Resolved
Each power-operated sliding watertight door shall be provided with an individual hand operated mechanism. It shall be possible to open and close the door by hand at the door itself from either side, and in addition, close the door from an accessible position above the bulkhead deck with an all round crank motion or some other movement providing the same degree of safety acceptable to the admin.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 4 January 2017
Resolved
The approx. time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of their movemnet with the ship in the upright position. Fire doors were found to close too quickly and dind't sequence properly. FD04.9.14, A60.9.04, A60.8.10, A60.8.16, A60.6.06, A60.6.10, A60.5.21, A60.11.03, A0.2.33, A60.5.21, A60.6.12.
Fire Fighting › Structural - B Class Divisions › Corridors
Issued 4 January 2017
Resolved
Continuous "B" class ceilings or linings, in association with the relevant decks or bulkheads, may be accepted as contributing, wholly or in part, to the required insulation and integrity of a division. Provide certificates to prove fiber board material meets requirements for class "B" linings. State rooms adjoining cat 2 stair fwd decks 10, 9, 8, 7, 6 passenger stairs (P/S)
Fire Fighting › Structural - B Class Divisions › Doors
Issued 4 January 2017
Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the division. B15 doors from Corridor ro Panorama Lounge (Deck 9) and forward to Observation Lounge Bar (Deck 11) were found to be unable to close and must remain closed at all times.
Fire Fighting › Means of Escape › Corridors
Issued 4 January 2017
Resolved
Safe escape routes shall be provided. Deck 5 Offices adjoining Main Lobby do not escape to a Corridor (room in room arrangement)
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 January 2017
Resolved
Fire integrity of bulkheads and decks in ships carrying more than 36 passengers. Insulation missing in Electrical Locker deck 11. Additionally, cover plate found missing in emergency escape trunk behind FD-A0.3.87
Personnel › Training › Passenger Safety
Issued 4 January 2017
Resolved
Every crew member assigned emergency duties shall be familiar with these duties before the voyage begins. Stairway guides knowledge and abilities were not consistently demonstrated. Fire teams did not follow shipboard procedures during demonstration of fire drill. Ship unable to account for all personnel missing during drills either excused or otherwise.
Fire Fighting › Miscellaneous Items › Electric Radiators
Issued 27 March 2014
Resolved
Code 0999- Construction and arrangements of Saunas. Electrically heated ovens shall be provided with a timer.
All of the Ships Saunas are fitted with thermostats but not timers. SOLAS (2004) CHII-2 Reg 9 2.2.3.4.6
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 27 March 2014
Resolved
A combustible waste receptacle labled PAPER only was found in the crew's designated smoking area outside the crew bar.
Construction/Loadline › Structures › Door
Issued 27 March 2014
Resolved
Found the following doors unable to close properly: Deck 07 Launderette door, deck 08 Launderette door, Deck 09 fire door A0 9 06, Deck 11 Launderette door.
Fire Fighting › Fire Hoses › Location
Issued 27 March 2014
Resolved
Blocked fire hose station outside of Port steering gear room, Deck 3.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 27 March 2014
Resolved
Blocked High-fog actuatuing valve for refer cold stores, deck 3.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 22 November 2010
Resolved
In Owner Suite #845DK8 Bedroom detector did not emit audible indication of action. When the smoke detector in the living & Bar area of the suite weere activated the audible indication fuctioned properly in the space but not in the bedroom.When detectors within another suite were activated the audible indication fuctioned.
Fire Fighting › Means of Escape › Blocked
Issued 22 November 2010
Resolved
SOLAS 74 (2009 consolidated ed) CH II-2 REG. 13.1 AC Station 12.2 On DECK 12 Escape route Signage is obstructed and No Emergency exit signage exsist.
Construction/Loadline › Structures › Trunk
Issued 22 November 2010
Resolved
SOALS 74 CONS 2009 ED. CH II-1 REG 3-1. Space Forward and AFT of the Bowthruster Tubes Is filled with a concrete or Resin substance similar to a cement box. Provide class reprot describing the purpose of the concrete stubstance and approval of proper rectification of this issue.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 22 November 2010
Resolved
SOALS 74 2009 CH II-2 REG 9.2.2.3.2.2 Combustibale material was found in mooring eletrical workstation Deck 3 Aft
Construction/Loadline › Structures › Door
Issued 22 November 2010
Resolved
Semi Watertight door # A.60.3.95 was blocked by Waste recepticals. SOLAS 74 (2009 Consolidated) CH II-1 Reg 21.2
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 22 November 2010
Resolved
Waste receptacles were found in boatswain hole, electrical workshop, and carpenters workshop of plastic construction with combustible material in them. SOLAS 2009 CH II-2 REG 4.4.2
Construction/Loadline › Hull › Transverse Frame
Issued 22 November 2010
Resolved
The Space FWD and AFT of the Bow thruster is filled wiht a concrete or resin substance similar to a cement box. Provide class report discribing the purpose of the concrete substance and approval of proper rectifiction of this issue. SOLAS 74 CH II-I Reg 3-1.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 22 November 2010
Resolved
A.C. Station 12.2 On Deck 12 has obstructed escape signage and no emergency exit signage exsist.
Fire Fighting › Fire Patrol › Call Points
Issued 22 November 2010
Resolved
Manually operated callpoint in Deck 8 Casino is blocked by curtain. Not visiable from casino floor. SOLAS CHII-2 Reg 7.7
Fire Fighting › Means of Escape › Emergency Lighting
Issued 22 November 2010
Resolved
Emergency lighting in Card room on deck 9 was not functioning.
Fire Fighting › Means of Escape › Blocked
Issued 22 November 2010
Resolved
Electrical workshop DECK3 aft was found to have been modified by adding an office within the workshop, and has no secondary means of escape. SOLAS CH II-2 Reg 13 3.2.2.
Fire Fighting › Structural - B Class Divisions › Cabin Doors
Issued 22 November 2010
Resolved
Vessel's hotel staff had several sections of the ship's cabains door wedges open with rubber stoppers, in addition can door #747 had its spring loaded closing device disconnected. SOLAS CHII-2 Reg 9 2.2.4.1.2.2