WESTERN STAR is a 1967 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 1996, most recently in November 2001, along with 65 deficiencies.

Records from 1996 to 2001. Most recent: inspection, 2 November 2001.

Built
1967
Last inspected
2 November 2001
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB4124
Flag
UNITED STATES
366895020 (licence lapsed)
Maury page id
psix-97005

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (1996–2001)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.5 ft × 17.0 ft × 8.0 ft
Registered tonnagegross 55 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUWAMISH WELDING & CONSTR · SEATTLE, WA, UNITED STATES · built 1967
Hull materialAluminum
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsRecreational
DocumentationValid · issued 8 July 2025 · expires 31 August 2030
Service, as the file records itPassenger (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB4124MMSI 366895020 · expired · voluntarily equipped · granted 23 May 2003, cancelled 27 July 2013
WCY7877MMSI not assigned · expired · compulsorily equipped · granted 7 December 1998, cancelled 7 February 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

2 November 2001 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1076457
11 June 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1389443
18 October 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1469984
22 September 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379193
27 July 2000 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 821301
13 January 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361315
28 June 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1464863
21 May 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399118
5 May 1999 Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375768
16 November 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1397027
21 October 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 802410
10 June 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375483
9 February 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388470
21 May 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1105736
8 May 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1392673
10 June 1996 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 876929
9 May 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371398
29 February 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 884555
29 January 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1186201

Deficiency record · 65

Construction/Loadline
Issued 18 October 2000 Resolved
Install a visual alarm at the operating station for the bilge high level alarm system in addtion to the audible alarm already installed.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Construction/Loadline
Issued 18 October 2000 Resolved
Adjust the location of the lazarette bilge high level alarm float switch toa lower location. Alarm should not sound for a very small amount of water,but should provide a reasonably early indication of flooding.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Documentation
Issued 22 September 2000 Resolved
Obtain an FCC Marine Radio Operator Permit.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Lifesaving
Issued 22 September 2000 Resolved
Register EPIRB with NOAA.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Lifesaving
Issued 22 September 2000 Resolved
Post an emergency broadcast placard.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Navigation
Issued 22 September 2000 Resolved
Provide current charts, tide table, and navigation rules.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Documentation
Issued 22 September 2000 Resolved
Post the COI and stability letter so both pages are visible.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Unknown
Issued 22 September 2000 Resolved
Provide proof that master and crew are enrolled in a compliant drug program.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Fire Fighting
Issued 22 September 2000 Resolved
Provide an additional A-II fire extinguisher on board vessel prior to operating with passengers for hire.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Lifesaving
Issued 22 September 2000 Resolved
Start leaving passenger count ashore whenever getting underway.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Accommodation/Occupational Safety
Issued 22 September 2000 Resolved
Replace cracked bridge window on port side.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Accommodation/Occupational Safety
Issued 22 September 2000 Resolved
Mark "Emergency Exit, Keep Clear" on the weather deck side of the emergencyescape.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Documentation
Issued 22 September 2000 Resolved
Have a qualified contracter issue a FCC Safety Cerificate for the vessel.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Accommodation/Occupational Safety
Issued 22 September 2000 Resolved
Make emergency exit operable from the weather deck or post sign inside stating "Keep Unlocked."
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Lifesaving
Issued 22 September 2000 Resolved
Replace O-rings on the 14 lifejacket lights identified by the marine inspector.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Fire Fighting
Issued 22 September 2000 Resolved
Attach lanyards to, and label, the 3 fire buckets. (or provide portable hand pump)
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Engineering
Issued 22 September 2000 Resolved
Put a second hose clamp on the starboard main engine raw water intake, justafter the strainer.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Construction/Loadline
Issued 22 September 2000 Resolved
Install a bilge high level alarm system for the lazarette, main cabin, engine room, and forward cabin prior to carrying passengers for hire.
Condition: Unknown
Due 22 September 2000
Resolved 22 September 2000
Fire Fighting
Issued 13 January 2000 Resolved
Extend piping in the fixed fire fighting systems for both the engine compartment and the generator compartment at least 2 inches beyond the lastorifice to reduce danger of clogging.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Accommodation/Occupational Safety
Issued 13 January 2000 Resolved
ENSURE PROPER HOSE CONNECTIONS ARE MADE ON ALL SEWAGE SYSTEM CONNECTIONS.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Fire Fighting
Issued 13 January 2000 Resolved
Provide plans to upgrade existing engine and generator space CO2 systems. Required components: CG approved heat detectors; alarms at operating station; crew instructions for fire posted near alarms; and powered ventilation capable of being manually secured from operating station.
Condition: Unknown
Due 13 January 2000
Resolved 13 January 2000
Lifesaving
Issued 21 May 1999 Resolved
Bring vessel into compliance with drug testing requirements of 46 cfr part 16
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Lifesaving
Issued 21 May 1999 Resolved
Conduct drills and u/w test in pressence of marine inspector
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Documentation
Issued 21 May 1999 Resolved
Conduct and log training as req by 46 CFR 185.420.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Fire Fighting
Issued 21 May 1999 Resolved
SUBMIT PROPOSAL TO UPGRADE MACHINERY SPACE FIXED GAS FIRE EXTINGUISHING SYSTEM OR REPLACE SYSTEM WITH A PRE-ENGINEERED SYSTEM. THIS PROPOSAL SHALL INCLUDE MACHINERY AND VENTILATION SHUT DOWNS. THIS REQUIREMENT IS DUE PRIORTO THE NEXT HULL EXAM
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Fire Fighting
Issued 21 May 1999 Resolved
SUBMIT PROPOSAL TO UPGRADE GENERATOR ROOM FIXED GAS FIRE EXTINGUISHING SYSTEM OR REMOVE EXISTING SYSTEM PROVIDED GENERATOR IS LESS THAN 37.3KW OR ENGINE IS LESS THAN 50HP.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Lifesaving
Issued 21 May 1999 Resolved
Conduct passenger count per 46 cfr 185.504.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Documentation
Issued 21 May 1999 Resolved
Post COI and stability letter.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Navigation
Issued 21 May 1999 Resolved
Conduct and log EPIRB tests.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Lifesaving
Issued 21 May 1999 Resolved
Renew 6 orange distress signals prior to 1 jun99
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Construction/Loadline
Issued 21 May 1999 Resolved
Make bulkheads watertight in way of all bilge piping penetrations.
Condition: Unknown
Due 21 May 1999
Resolved 21 May 1999
Construction/Loadline
Issued 5 May 1999 Resolved
MAKE VALVES READY FOR INSPECTION
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 16 November 1998 Resolved
RENEW R/W HOSE ON SEA SUCTIONS IN AFT COMPT BILGE WITH APPROVED HOSE.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Construction/Loadline
Issued 16 November 1998 Resolved
restore bilge piping and bilge pump as original
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 16 November 1998 Resolved
INSTALL SPACERS BETWEEN LIFEFLOATS
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Engineering
Issued 16 November 1998 Resolved
Adjust l/o/ alarms
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Accommodation/Occupational Safety
Issued 16 November 1998 Resolved
REPAIR AS NEW SEWAGE SYSTEM IN WAY OF AFT COMPT BILGE USE APPROVED HOSE.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 16 November 1998 Resolved
STOW FLARES IN WATERPROOF CONTAINIER PER 46CFR185.614
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Construction/Loadline
Issued 16 November 1998 Resolved
INSTALL REMOTE REACH ROD ON BILGE SUCTION VALVE IN WAY OF COLLISION BULKHEAD
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Lifesaving
Issued 16 November 1998 Resolved
INSTALL LIFEFLOAT PAINTERS CORRECTLY
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Navigation
Issued 16 November 1998 Resolved
HAVE ON BOART UPDATED COPIES OF COAST PILOT, LIGHTLIST, NEW "T" REGS, NTMS AND UPDATE CHARTS
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Construction/Loadline
Issued 16 November 1998 Resolved
RENEW BILGE PIPING W/APPROVED PIPE IN WAY OF PVC PIPING
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Fire Fighting
Issued 16 November 1998 Resolved
POST COMPLETE AND SIMPLE INSTRUCTIONS FOR OPERATING OF FIXED GAS EXTINGUISHING SYSTEM
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Engineering
Issued 16 November 1998 Resolved
REPAIR AS NEW ENGINE ALARMS
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Lifesaving
Issued 16 November 1998 Resolved
HAVE ON BOARD AN APPROVED FIRST AID KIT OR EQ
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Navigation
Issued 16 November 1998 Resolved
REPAIR AS NEW STEERING SYSTEM
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Fire Fighting
Issued 16 November 1998 Resolved
SUBMIT PROPOSAL TO UPGRADE FIXED GAS FIRE EXTINGUISHING SYSTEM TO INCLUDE MACHINERY AND VENTILATION AUTOMATIC SHUTDOWNS IN THE EVENT OF DISCHARGE.
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Engineering
Issued 16 November 1998 Resolved
repair as new fuel leak on genset and clean bilges of fuel
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Engineering
Issued 10 June 1998 Resolved
RENEW R/W SUCTION HOSE FOR SERVICE TO GENERATOR
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Electrical
Issued 10 June 1998 Resolved
STRAIGHTEN UP WIRING TO ELECTRICAL BILGE PUMP IN WAY OF AFT COMPT.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Engineering
Issued 10 June 1998 Resolved
REPAIR AS NEW F/O RETURN LINE IN WAY OF PORT F/O TANK USING APPROVED HOSE.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Construction/Loadline
Issued 10 June 1998 Resolved
RENEW A FLEXIBLE NON-METALLIC HOSE CONNECTIONS IN BILGE PIPING
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Engineering
Issued 10 June 1998 Resolved
INSTALL EXHAUST LAGGING ON E/R EXHAUST PIPING
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Engineering
Issued 10 June 1998 Resolved
INSTALL GUARDS FOR V-BELTS.
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Construction/Loadline
Issued 10 June 1998 Resolved
INSTALL CHECK VALVES IN BILGE PIPING SYSTEM BETWEEN ELECTRICAL PUMP AND OVBD AND DECK SINK DRAINS AND OVBD
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Fire Fighting
Issued 10 June 1998 Resolved
INSTALL CO2 BOTTLES FOR FFS SO AS TO HAVE A MINIMUM OF 2" SPACE BETWEEN BOTTLE AND RACK PER 46CFR 181.410
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Engineering
Issued 10 June 1998 Resolved
RENEW ALL EXHAUST PIPE IN WAY OF WET EXHAUST W/ SCHEDULE 80 PIPING
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Engineering
Issued 10 June 1998 Resolved
RENEW ALL F/O LINES TO ENGINES W/APPROVED TYPE.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Engineering
Issued 10 June 1998 Resolved
REPAIR AS NEW ALL LEAKS IN EXHAUST SYSTEM PIPING
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Engineering
Issued 10 June 1998 Resolved
SUBMIT PLAN OR SPECIFICATION DETAILING PROPOSED MODIFICATIONS TO HULL INCLUDING WEIGHTS DIFFERENCES & HORSEPOWER/TORQUE RATIOS.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Engineering
Issued 10 June 1998 Resolved
RENEW PLASTIC GUAGE LINE FOR SERVICE TO GEAR OIL PRESSURE GUAGE W/APPROVED HOSE
Condition: Unknown
Due 10 June 1998
Resolved 10 June 1998
Lifesaving
Issued 8 May 1997 Resolved
Perform drill as per 46 CFR 185.420 in the presence of the local inspector.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Accommodation/Occupational Safety
Issued 8 May 1997 Resolved
Remove extra gear and place ashore until needed.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Documentation
Issued 8 May 1997 Resolved
Provide a 46 CFR part 166 to 199 revised as of October 1, 1996.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Documentation
Issued 8 May 1997 Resolved
Make an Emergency Broadcast Placard as per 46 CFR 183.506.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.