Records from 1989 to 2017. Most recent: inspection, 4 May 2017.
Documentation record
Registered dimensions (L × B × D)60.2 ft × 28.0 ft × 5.3 ft
Registered tonnagegross 94 / net 79
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJACKUP BOAT BUILDERS INC · CAERNARVON, LA, UNITED STATES · built 1968
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 August 2026 · expires 30 September 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
79 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
4 May 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6138944
9 December 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5778247
18 November 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3105848
19 June 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2684855
27 April 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2634759
12 April 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2624080
14 July 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2132913
12 July 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2130922
9 May 2003
Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1789998
11 October 2001
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463710
3 August 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405029
16 August 1999
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466071
23 July 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440027
1 October 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1117689
14 August 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422894
7 January 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1098143
4 October 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465879
1 October 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 833616
25 July 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454355
16 August 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402090
9 September 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177513
15 August 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 865902
2 August 1994
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460721
4 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455143
12 October 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 670054
6 October 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 33539
17 September 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435407
29 September 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1253165
27 July 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 959194
3 October 1991
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245530
7 August 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1251950
17 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248650
11 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934632
9 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243959
8 January 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215684
6 November 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219646
4 October 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901680
1 August 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219771
8 June 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219025
29 May 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1225905
14 March 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 912954
5 March 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 923441
13 February 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 918202
18 October 1989
Inclining Experiment · Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934881
18 January 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924825
Construction/Loadline
Issued 14 August 1997
Resolved
MAKE PROPER REPAIRS TO STBD BOW INSET AS DISCUSSED.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Unknown
Issued 25 July 1996
Resolved
CLEAR WORKLIST ITEMS ISSUED AT COI.
Condition: Unknown
Due 2 August 1996
Resolved 12 August 1996
Electrical
Issued 16 August 1995
Resolved
Properly stuff electrical through deck tubing in galley
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Accommodation/Occupational Safety
Issued 16 August 1995
Resolved
Install on board covered metal trash containers.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Construction/Loadline
Issued 16 August 1995
Resolved
Gouge and repair deck longitudinal in way of engine room vent.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Electrical
Issued 16 August 1995
Resolved
Properly label stove disconnect on electrical panal.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Electrical
Issued 16 August 1995
Resolved
Repair oil leak on service generator.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Deck/Cargo
Issued 16 August 1995
Resolved
Replace anchor ropes.
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Documentation
Issued 2 August 1994
Resolved
LOCATE AND PLACE VESSEL'S STABILITY LETTER ON BOARD AS PER 46 CFR 97.11-1.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Documentation
Issued 3 October 1991
Resolved
INSTALL GARBAGE AND PLASTIC PLACARD.
Condition: Unknown
Due 3 November 1991
Resolved 23 October 1991
Construction/Loadline
Issued 3 October 1991
Resolved
WELD FRACTURE IN STARBOARD SKEG AND RUDDER SUPPORT.
Condition: Unknown
Due 3 November 1991
Resolved 23 October 1991
Documentation
Issued 3 October 1991
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.: INBOARD AND OUTBOARD PROFILES, LEGSTRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS._x001C_
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Documentation
Issued 3 October 1991
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER FOR REVIEW AND APPROVAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Construction/Loadline
Issued 3 October 1991
Resolved
WELD FOUR FRACTURES ON PORT PAD.
Condition: Unknown
Due 10 November 1991
Resolved 23 October 1991
Construction/Loadline
Issued 3 October 1991
Resolved
WELD FRACTURE IN WELD CONNECTION OF STERN LEG SUPPORT TO HULL PLATING ON PORT SIDE.
Condition: Unknown
Due 3 November 1991
Resolved 23 October 1991
Documentation
Issued 3 October 1991
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT OCMI._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Documentation
Issued 3 October 1991
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C. VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL THE COAST GUARD APPROVED MANUAL IS RECEIVED.
Condition: Unknown
Due 12 November 1991
Resolved 12 November 1991
Documentation
Issued 8 June 1990
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC. VESSEL IS PERMITED TO OPERATE ON IT'SEXSISTING OPERATING MANUAL UNTIL U.S. COAST GUARD APPROVED OPERATING MANUALIS RECEIVED.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Documentation
Issued 8 June 1990
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, DC: INBOARD AND OUTBOARD PROFILES, LEG STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRALIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Documentation
Issued 8 June 1990
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM #1 TO THE COGNIZANT OCMI.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Documentation
Issued 8 June 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Documentation
Issued 13 February 1990
Resolved
SUBMIT STABILITY CALCULATI0NS T0 THE U.S. C0AST GUARD MARINE SAFETY CENTER WASHINGT0N, D.C. F0R REVIEW AND APPR0VAL.
Condition: Unknown
Due 13 February 1990
Resolved 13 February 1990
Electrical
Issued 18 October 1989
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP, LOW LUBE OIL SHUTDOWN AND HIGH COOLING WATER TEMPERATURE ALARM ON SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Lifesaving
Issued 18 October 1989
Resolved
PROVIDE A U.S. COAST GUARD APPROVED RESCUE BOAT OR SUBMIT AN ALTERNATE PROPOSAL FOR APPROVAL.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Lifesaving
Issued 18 October 1989
Resolved
PROVIDE EMBARKATION MEANS TO ESCAPE FROM VESSEL WHEN IN THE ELEVATED MODE TO COMPLY WITH 46 CFR 108.525.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Documentation
Issued 18 October 1989
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THT U.S. COAST GUARD MARINE SAFTY CENTER, WASHINGTON, D.C.: INBOARD AND OUTBOARD PROFILES, LEG STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEMS DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Documentation
Issued 18 October 1989
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM #1 TO THE COGNIZANT OCMI.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Documentation
Issued 18 October 1989
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C. VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL U.S. COAST GUARD APPROVED OPERATING MANUAL IS RECEIVED.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Documentation
Issued 18 October 1989
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER,WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989