MSC TIANPING is a 2006 freight ship. The Coast Guard has recorded 15 inspections since 2016, most recently in February 2023, along with 4 deficiencies and 2 operational controls.
Records from 2016 to 2023. Most recent: inspection, 12 February 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it103404 - Dead Weight, Ton 137280 - Displacement, Ton 91649 - Convention (Subpart B), Gross Ton 56693 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
12 February 2023PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7635561
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 February 2022Resolved
DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLE GASTIGHT AND SELF-CLOSING. FIRE DOOR LEADING FROM DECK TO PAINT STORE CLASS "A" SELF-CLOSING DOOR ACCORDINF TO FIRE CONTROL PLAN. FIRE DOOR WAS NOT SELF-CLOSING WHEN INSPECTED AND HINGES REMOVED/DOOR DAMAGED - DOES NOT MEET "A" CLASS STANDARD. 74 SOLAS (2004 CONS.) II-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 February 2022
Resolution: CREW ADDED HINGE TO DOOR THAT ALLOWED IT TO BE SELF-CLOSING BEFORE [name withheld] VESSEL.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 February 2022Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THE SHIP IN ALL ASPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR ANY PERSON ONBOARD. FUEL TANK CONNECTIONS IN STBD LIFEBOAT LOOSE AND FUEL LEAKING. 74 SOLAS (2020) I/11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 February 2022
Resolution: THIRD ASSISTANT ENGINEER TIGHTENED FITTINGS AND PSCO VERIFIED TIGHT CONNECTION/NO FUEL LEAKING BEFORE DEPARTING VESSEL.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 February 2022Resolved
FIRE PROTECTION SYSTEMS AND FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. CO2 PORTABLE EXTINGUISHER IN OXYGEN STORE ROOM ON DECK WAS NOT ACCESSIBLE - BLOCKED BY OXYGEN BOTTLES. 74 SOLAS (2004 CONS.) II-2/14.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 3 February 2022
Resolution: CREW DEMONSTRATED TO [name withheld] VESSEL THAT CO2 EXTINGUISHER ACCESSIBLE IN THE OXYGEN STORE ROOM ON DECK; SAT.
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 17 February 2016Resolved
Each emergency generating set arranged to be automatically started shall be equipped w/starting devices approved by the Administration w/a stored energy capability of at least 3 consecutive starts. The vessel's emergency generator cannot be started automatically, only manually. 74 SOLAS(04 CONS) II-1/44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2016
Resolved 19 February 2016
Resolution: Vessel submitted class report. Class determined issue was due to faulty controllers in emergency generator switchboard. Vessel ordered parts. Class gave until 30March to effect repairs.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National