MAURY USCG vessel records
← All vessels

IMPALA

IMPALA is a 2008 freight ship. The Coast Guard has recorded 28 inspections since 2018, most recently in March 2025, along with 13 deficiencies and 3 operational controls.

Records from 2018 to 2025. Most recent: inspection, 11 March 2025.

Built
2008
Last inspected
11 March 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 March 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9370111
971393
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-971393

Documentation record

Tonnage as PSIX records it17970 - Displacement, Ton
13450 - Dead Weight, Ton
9556 - Convention (Subpart B), Gross Ton
4378 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

28 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

11 March 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8088219
5 September 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7995594
17 March 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7880631
17 March 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7882362
14 March 2024 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7878923
14 September 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7791307
8 September 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7782827
21 February 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7640180
19 February 2023 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7638832
8 August 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7519612
6 June 2022 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7463286
2 April 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7423288
9 February 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7393709
9 November 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7343173
4 November 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7345369
4 November 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7345596
5 August 2021 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7277815
3 August 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7275892
15 July 2021 PSC B · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7251299
15 October 2020 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7077559
12 September 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7056554
24 January 2020 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6895552
14 August 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6782992
12 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6370201
21 February 2018 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6358528
22 January 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6340345
16 January 2018 ISPS II Exam · Ballast Water Examination · COE-Dockside · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6334157
8 January 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6334336

Deficiency record · 13

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 September 2023 Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 min. Crew was unable to start rescue boat. 74 SOLAS (2020) III/14.1. 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2023
Resolved 9 September 2023
Resolution: Received, reviewed and accepted class report from LR stating the deficiency was rectified. Vessel cleaned fuel filter and was able to start the boat 4 time in a row after.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 6 June 2022 Resolved
The voyage data recorder system, including all sensors shall be subjected to an annual performance test. The test shall be conducted by an approved testing or service facility to verify the accuracy duration and recoverability of the recorded data. In addition tests and inspections shall be conducted to determine the serviceability of protective enclosures and devices fitted to aid location. A copy of the certificate of compliance issued by the testing facility stating the date of compliance and the applicable performance standards shall be retained on board the ship. During bridge exam PSCE noted “incident left (1)” on VDR panel. Crew could not show PSCE records of incidents, stating a Technician is needed to access the records. 74 SOLAS(20) V/18.8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2022
Resolution: Received technician report stating VDR is operational with no faults.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 June 2022 Resolved
A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. PSCO observed vessels secondary means of starting emergency generator was inoperable due to broken manual start handle. 74 SOLAS (20) II-1/44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2022
Resolution: Witnessed repairs to manual start mechanism on EDG. Conducted test, satisfactory starts of EDG in accordance with SOLAS regulations.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 July 2021 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED AN ACTIVE LEAK ON THE MGO TRANSFER LINE AND MDE #7 FUEL INJECTOR IN THE MACHINERY SPACE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2021
Resolution: rectified.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 July 2021 Resolved
THE MINIMUM FIRE INTEGRITY OF BULKHEADS AND DECKS SHALL BE AS PRESCRIBED IN TABLES 9.6. PSCO OBSERVED DETERIORATION OF A TEMPORARY REPAIR ON THE INCINERATOR DECK ROOM RESULTING IN EXCESSIVE CORROSION TO DECK, AND "A" CLASS BOUNDARY.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2021
Resolved 5 August 2021
Resolution: PSC SEC HOU-GAL received a class reports from DNV satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 12 September 2020 Resolved
All lifesaving appliances shall be in good working order and ready for immediate us. The hydraulic line on the rescue boat davit burst. 74SOLAS(2014) CH.III Reg. 20.2 17a,c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 August 2019 Resolved
Nozzles shall be of an approved dual-purpose type; port and starboard bridge fire hose nozzles are incapable of switching to fog. Nozzle is only capable of spray. 74 SOLAS (2004) II-2/10.2.3.3.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 24 January 2020
Resolution: RECEIVED REPORT FROM M/V IMPALA THAT NEW APPROVED FIRE NOZZLES HAD BEEN PURCHASED AND INSTALLED, RECTIFYING DEF.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 16 January 2018 Resolved
Vessel must have a receiver for a global navigation satellite system or a terrestrial radio navigation system suitable for use at all times throughout the intended voyage to establish and update the ships position by auntomatic means. PSCO observed an inoperable GPS while conducting bridge exam. Inoperable GPS was causing an error code on the voyage data recorder. 74 SOLAS(04) REG V 19.2.6.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2018
Resolution: GPS no.1 was repaired and GPS no.2 was replaced by Radio Holland technician. Vessel now has 3 working GPS units.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 16 January 2018 Resolved
Means shall be provided for the crew to safely check the quantity of the medium in the container. PSCO found 8-10 safety pins missing from the system. -74 SOLAS(04) II-2 REG 10 4.1.1.1.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 January 2018
Resolved 16 January 2018
Resolution: CORRECTED ON SPOT.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 16 January 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform to the provisions of the present convention. PSCO found that the incinerator was not used, maintained, or operating. -MARPOL ANNEX I REG 6.4.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2018
Resolution: Incenterator was electrically isolated and was removed from the IOPP and IAPP
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 16 January 2018 Resolved
Vessel shall carry a written procedure showing how the fuel change over is to be done. PSCO was not provided with a written procedure. -MARPOL ANNEX VI REG 14.6.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 January 2018
Resolution: Preceedures were provided to attending CG Marine Inspector and attending class surveyor and were found to be to the
Documentation › Logs/Records › Logbook (official)
Issued 16 January 2018 Resolved
IF the vessel has any equipment that starts operating improperly during a voyage it must be reported to the captain of the port prior to arrival via the notice of arrivals process. -33CFR164.53(a)
Due 16 January 2018
Resolved 16 January 2018
Resolution: Corrected on spot.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 16 January 2018 Resolved
A 2nd source of emergency power shall be provided for the starting of the emergency generator. Secondary means were not availiable. -74SOLAS(04) II-I REG 44.2.1.
Due 16 January 2018
Resolved 16 January 2018
Resolution: CORRECTED ON SPOT.

Ownership record