TIGER CAT

TIGER CAT is a 2008 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in April 2026, along with 51 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 29 April 2026.

Built
2008
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE6490
972152
Flag
UNITED STATES
Maury page id
psix-972152

Documentation record

Registered dimensions (L × B × D)34.0 ft × 22.0 ft × 5.0 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVERSACAT LLC · MIAMI, FL, UNITED STATES · built 2008
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 51 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

29 April 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8357847
9 September 2025 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8230498
28 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8148347
28 February 2024 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7868032
11 October 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7806948
22 June 2022 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7485020
9 November 2021 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7250717
9 June 2021 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7208389
29 June 2020 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6984070
7 November 2019 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6851281
3 April 2019 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6640977
22 June 2018 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6452142
2 November 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6307882
3 July 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6200031
22 June 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5912928
7 March 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5824018

Deficiency record · 51

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2026 Resolved
Provide a means to make the port forward electronic submersible bilge pump operate automatically or mark the switch "Manual Only".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2026 Resolved
Mark the life jacket stowage locations with the number and identification of life jackets stowed inside in numbers and letters at least 2" high (15 Adult Life Jackets).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2026 Resolved
Mark the fuel shut off valve locations in a visible location.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 12 May 2026
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 May 2025 Resolved
The hydrostatic release for the Cat 1 EPIRB is expired. Replace, mark, and install the hydrostatic release so the EPIRB will automatically float free.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 May 2025 Resolved
Provide 6 additional red flare signals or 6 additional orange smoke signals so a total of 12 distress signals are on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 May 2025 Resolved
Provide 2 additional adult life jackets. Vessel restricted to carrying 38 passengers and 40 total persons.
Action required: 705 - Other - as specified
Resolved 28 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 May 2025 Resolved
Provide 1 additional 2.5 gallon fire bucket, label, and attache a lanyard long enough to reach the waterline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 28 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2025 Resolved
Provide an operational port navigation light prior to operating during periods of reduced visibility.
Action required: 705 - Other - as specified
Resolved 4 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 May 2025 Resolved
Replace gasket material and repair latches and hinges on identified deck hatches to make them watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 May 2025 Resolved
Seal all deck penetrations and former screw holes to make the deck watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 May 2025 Resolved
Service or provide a new 10-B:C fire extinguisher. Mount extinguisher in a proper bracket and label location if not readily visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 May 2025 Resolved
Mount the 40-B:C fire extinguisher in a proper bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 May 2025 Resolved
Provide a visual indicator for the high water alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 May 2025 Resolved
Provide 100 aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2025 Resolved
Replace the retro-reflective material on the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 May 2025 Resolved
Mark the life jacket storage locations with the type and number of life jackets in letters at least 4 inches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 May 2025 Resolved
Strengthen the deck rail bases as identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 4 June 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 June 2022 Resolved
The battery in the vessel's FCC Type Accepted Category 1, 406 MHz EPIRB is expired. Provide proof of the current EPIRB properly serviced with a new battery installed or purchase a new Category 1, 406 MHz EPIRB and show proof of registration prior to carrying passengers.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2022
Resolution: Vessel rep purchased new EPIRB and registered it with NOAA prior to the end of the inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 November 2019 Resolved
Repair all soft spots, blisters and crack locations identified (i.e. port side aft deck aft of head compartment, areas marked on both port and starboard hulls, cross members, tabbing in forward compartment on starboard side, and two locations identified in port hull, and all other self identified locations), submit repair proposal to include material type (Glass type, weight, and resin). Area must be properly prepped and ground down to good glass and reinspected by marine inspector prior to carrying out repairs.
Action required: 705 - Other - as specified
Resolved 5 December 2019
Resolution: repaired gouge in sideshell and crossmember
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 November 2019 Resolved
Thru hull valve is not securely seated against the hull. Hull must be watertight. Re-seat thru hull valve and retest with a marine inspector in attendance.
Action required: 705 - Other - as specified
Resolved 3 December 2019
Resolution: replaced and retested
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2019 Resolved
Provide properly sized over-current protection for power assist hydraulic steering pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 April 2019 Resolved
Provide a metallic positive shutoff valve at the hull penetration for each installed submersible bilge pump (04) total.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2019 Resolved
Electrical equipment exposed to corrosive environments must be of suitable construction and corrosion resistant. Provide documentation for 50amp Blue Sea breakers in Port and STBD hulls are suitable for installed location or relocate fuses waterproof/drip proof enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2019 Resolved
Provide fuses that are cartridge type and UL listed for breaker panel in console. Fuses are of the automotive type (ATO). Electrical plans approved on April 9th, 2009 do not indicate the type that were installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2019 Resolved
Installed SeaStar hydraulic power assist attached to main ungrounded conductor supplying breaker panel with no over-current protection. Electrical Plans approved on April 9th, 2009 does not indicate power assist steering system, provide owners manual/installation manual to confirm proper installation. Submit Electrical plans of installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2019 Resolved
Provide hose specifications for hydraulic steering lines. Orginal plans do not indicate power assist steering system. Specs needed to verify properly sized burst pressure for hoses is 4x maximum working pressure of steering system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2019 Resolved
Provide electrical plans for installed batteries (02)in console, to include switches, length of wires, and size. Electrical plans approved on April 9th, 2009 do not indicate installed batteries in console, no records of notifying USCG to conduct alterations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2019 Resolved
Replace ring buoy; mark new buoy with reflective tape and vessels name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 April 2019 Resolved
Label automatic bilge pump indicating lights
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 April 2019 Resolved
Repair/replace automatic bilge indicating light for Portside forward compartment, light was weak when tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 3 April 2019 Resolved
Provide light for magnetic compass, vessel restricted to daylight operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 April 2019 Resolved
Provide valid FCC Station license for vessel
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 April 2019 Resolved
Provide up to date publications to include US. Coast Pilot [name withheld] for area operated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2019 Resolved
Provide 03 Fire buckets, buckets shall be 2.5 gallons, with lanyard and labeled "fire bucket".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2019 Resolved
Provide up to date electrical drawings for installed electrical system. Current installed system does not match approved electrical plans dated April, 9th 2009. Plans shall be sent to USCG Marine Safety Center; [email withheld] for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 October 2019
Communications › Radio Communications › VHF Radiotelephone
Issued 22 June 2018 Resolved
Provide a valid FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2018
Resolution: Safety Cert. onboard
Communications › Radio Communications › VHF Radiotelephone
Issued 22 June 2018 Resolved
Provide GPS for installed VHF Radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2018
Resolution: GPS input operational
Stability › Watertight Integrity › General
Issued 22 June 2018 Resolved
Repair/replace gasket on STBD forward hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2018
Resolution: Gasket replaced
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 June 2018 Resolved
Clearly mark all PFD stowage locations for both Adult and Child.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2018
Resolution: PFD locations marked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 22 June 2018 Resolved
Provide adequate ventilation for Port and STBD aft compartments that are elevated 12inches from the weather deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 August 2018
Resolution: Ventilation provided that is elevated from the weather deck.
Stability › Watertight Integrity › General
Issued 2 November 2017 Resolved
Grind out to good glass at identified areas (4 areas) on port hull.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: Completed repairs.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 3 July 2017 Resolved
Provide overcurrent protection for four submersible electric bilge pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 13 July 2017
Documentation › Certificates/Documents › Stability Letter
Issued 3 July 2017 Resolved
Post all pages of Stability Letter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 13 July 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 July 2017 Resolved
Post all pages of Certificate of Inspection
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 13 July 2017
Communications › Radio Communications › EPIRB
Issued 3 July 2017 Resolved
EPIRB hydrostatic release expired
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 3 July 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 3 July 2017 Resolved
Replace one BI fire extinguisher. The extinguisher was discharged.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 3 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 June 2016 Resolved
Vessel had expired items in first aid kit.
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 24 June 2016
Resolution: Owner purchased new replacement first aid kit.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 June 2016 Resolved
Fire extinguishers require annual servicing.
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 29 June 2016
Resolution: Extinguishers serviced.
Construction/Loadline › Hull › Transverse Frame
Issued 7 March 2016 Resolved
Port transom had cracks on either side of motor. Required owner to grind back crack to reveal depth/severity of crack and determine repair plan.
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 8 March 2016
Resolution: Crack was ground back and determined to be superficial in nature, only penetrated through the gel-coat resin, not actually through any fiberglass. Resin filled in and re-sealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 March 2016 Resolved
Found several dead-end wires throughout the vessel. Instructed owner to identify their purpose and either remove or re-employ the wires.
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 8 March 2016
Resolution: Each wire was identified and reattached to the appropriate equipment (power pole motors)
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 March 2016 Resolved
Fuel tank was not properly bonded to the hull to prevent build-up of static electricity.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 8 March 2016
Resolution: Bonding strap was re-attached.