Records from 2016 to 2026. Most recent: inspection, 13 July 2026.
Inspection history · 10
13 July 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8437460
7 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8204761
10 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7931596
11 December 2023
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7837247
5 June 2023
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7704018
24 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7145446
19 November 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6858047
3 December 2018
COI Inspection · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6589996
30 October 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6298382
24 October 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6029106
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 June 2023
Resolved
A vessel on rivers route must carry three hand red flares distress signal and three hand orange smoke distress signals. Vessel is missing one hand red flare.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2023
Resolved 5 June 2023
Resolution: An additional red flare was stored onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2023
Resolved
The ring life buoy retroflective tape was worn and must be replaced with Type II retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2023
Resolved 5 June 2023
Resolution: New type II retroflective tape was installed in vessel's lifering buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 June 2023
Resolved
Three fire buckets of 2.5 gal capacity required. Missing bucket needs to be replaced with a bucket of the right size and properly marked.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2023
Resolved 5 June 2023
Resolution: The boat is now suited with three 2.5 gal fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 November 2019
Resolved
Each ring life buoy must be marked with type II retroreflective material approved in accordance with 46 CFR 185.604 I or other standard specified by Commandant. Retro was worn and dry rotten. Retroreflective material must be replaced and evidence provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 19 November 2019
Resolution: Operator provided evidence of new SOLAS Type II tape purchase and sent photo of proper application.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 November 2019
Resolved
Operator shall be prepared to conduct test and have the vessel ready for inspections of the hull structure and its appurtenances. Vessel had a crack on both the port and starboard sides of the hull. Cracked welds need to be grinded down and repaired and evidence provided.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 12 December 2019
Resolution: Accepted picture of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2018
Resolved
ONE LIFEJACKET IS REQUIRED FOR EACH PERSON ON BOARD. VESSEL HAS FIVE ADULT AND ONE CHILD SIZED LIFEJACKET WHICH IS NOT SERVICEABLE. VSL IS RESTRICTED TO CARRYING 11 PASSENGERS UNTIL LIFEJACKETS ARE REPLACED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2019
Resolved 7 December 2018
Resolution: Company purchased all required life jackets, and stenciled with the vessel name, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 December 2018
Resolved
RING BUOY LIFE LINES ARE REQUIRED TO BE ATTACHED TO AT LEAST ONE RING BUOY. VSL HAS LIFE LINE HOWEVER IT IS DETERIORATED FROM U/V EXPOSURE. VSL MUST REPLACE LINE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2019
Resolved 7 December 2018
Resolution: Appropriate length of approved line was placed on the ring buoy, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 December 2018
Resolved
ONE WATERLIGHT MUST BE ATTACHED TO A RING BUOY VIA CORROSION RESTISTANT CLIP. VSL HAS WATERLIGHT HOWEVER IT IS NOT ATTACHED TO RING BUOY AND THE LANYARD IS DETERIORATED FROM U/V EXPOSURE. VSL MUST REPLACE LANYARD AND ATTACH TO RING BUOY.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2019
Resolved 7 December 2018
Resolution: Line was replaced and placed on the ring buoy, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2018
Resolved
THREE FIRE BUCKETS ARE REQUIRED ON BOARD. ONE FIRE BUCKET IS NOT SERVICEABLE. VSL MUST REPLACE ONE FIRE BUCKET.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2019
Resolved 7 December 2018
Resolution: 1 new fire bucket with vessel name was placed in the vessel with the other two buckets, all sat.