GAS ALYSSA
GAS ALYSSA is a tank ship. The Coast Guard has recorded 16 inspections since 2008, most recently in June 2026, along with 14 deficiencies and 2 operational controls, 1 with no removal date recorded.
Records from 2008 to 2026. Most recent: inspection, 18 June 2026.
- Built
- Not recorded
- Last inspected
- 18 June 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9364394 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
YDQU2
976472
Flag
INDONESIA
—
Maury page id
psix-976472
Inspections, by type
…with no type recorded2
Years with a record
11 calendar years (2008–2026)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it48425 - Regulatory (Subpart C or D), Gross Ton
73561 - Displacement, Ton
54706 - Dead Weight, Ton
17129 - Regulatory (Subpart C or D), Net Ton
48425 - Convention (Subpart B), Gross Ton
17129 - Convention (Subpart B), Net Ton
73561 - Displacement, Ton
54706 - Dead Weight, Ton
17129 - Regulatory (Subpart C or D), Net Ton
48425 - Convention (Subpart B), Gross Ton
17129 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
18 June 2026
PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8394962
20 June 2025
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8154598
29 December 2024
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8051669
22 May 2024
PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7912150
18 August 2023
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7762190
10 December 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7607190
14 June 2022
PSC B · Deficiency Check · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7470853
13 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7254749
30 November 2020
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7099577
12 February 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6907886
20 August 2019
COC-GAS Annual · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6785586
15 August 2018
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6500023
26 December 2015
COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5787259
21 August 2008
ISPS II Exam · Ballast Water Examination · COC-TVE Renew · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3299407
20 August 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3299406
20 August 2008
Type not recorded
No type recorded · USCGC STURGEON (WPB 87336) · USCG Northeast District (CGD-NE) · Activity 3424065
Deficiency record · 14
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 June 2026
Resolved
The system should be capable of covering all areas mentioned in 11.3.1 with a uniformly distributed water spray.
The PSCO observed 09 water spra nozzles not work as intended.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 22 May 2024
Resolved
ON SHIPS CARRYING FLAMMABLE OR TOXIC PRODUCTS OR BOTH, A WATER-SPRAY SYSTEM FOR COOLING, FIRE PREVENTION AND CREW PROTECTION SHOULD BE INSTALLED TO COVER EXPOSED CARGO TANK DOMES AND ANY EXPOSED PARTS OF CARGO TANKS, AND CARGO LIQUID AND VAPOR DISCHARGE AND LOADING MANIFOLDS.
PSCO OBSERVED INSUFICIENT COVERAGE OF TANK TOPS 1, 2, AND 3, AND PORT AND STARBOARD MANIFOLDS.
SOLAS 74 (20) VII/13.1
IGC '93 11.3.1.1
17ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 May 2024
Resolved
OBJECTIVE EVIDENCE DISCOVERED IN AN EXPANDED ISM EXAM REVEALED THE FOLLOWING MAJOR NON-CONFORMITY; THE VESSEL FAILED TO FULLY IMPLEMENT THE REQUIREMENTS OF THE SMS AS EVIDENT BY ABOVE DEFICIENCY. AN INTERNAL AUDIT IS REQUIRED PRIOR TO NEXT U.S. PORT AFTER FOREIGN.
SOLAS 74 (20) IX/3.1
ISM CODE 10.1
40ac
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 June 2022
Resolved
Mechanical ventilation inlets and outlets should be arranged to ensure sufficient air movement through the space to avoid the accumulation of flammable or toxic vapors and to ensure a safe working environment. Upon inspection, PSCO's could not verify proper operation of the compressor room ventilation system.
Cite: 74SOLAS(04Condensed)VII / 13.1 - IGC(93) 12.1.2
Action taken: 17AC + Cargo restricted on COC
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 14 June 2022
Resolved
Gas Detection equipment should be so designed that it may be readily tested. Suitable equipment and span gas for this purpose should be carried onboard. PSCO's could not verify calibration or witness proper calibration of the fixed gas sampling equipment. Further, proper span gas as outlined in the Omicron manual could not be located onboard.
Cite: 74SOLAS(04consed.) VII/13.1 - IGC (93) 13.6.6
Action taken: 17AC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 December 2020
Resolved
Cite 74 SOALS 14 II-2/4.2.2.5.4
Connections within the fuel supply and spill lines shall be constructed having regard to their ability to prevent pressurized oil fuel leaks while in service and after maintenance.
Observed excessive fuel oil leaks on #2 & #4 main engine fuel injectors fuel pump boosters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2020
Resolved
Cite 74 SOLAS 14 II-1/45.1.3
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner.
The newly installed #1 generator breaker leaves a 4mm gap, allowing access to the inside of the switchboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2020
Resolved
Cite 74 SOLAS 14 XII/13.1 IGC 93 CH 11.3.2
The system should be capable of covering all areas mentioned in 11.3.1 with a uniformly distributed water spray.
When the water spray system was tested #1 and #2 cargo tank domes, and port & starboard cargo manifolds were inaffectively protected due to clogged nozzles. Crew flushed and cleaned system. Demonstrated satisfactory test. Deficiency rectified.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 20 August 2019
Resolved
Every ship of 100 gross tons and above shall carry a garbage management plan. Plan shall provide written procedures for collecting and disposing of garbage. Vessel has expired span gas onboard dating back to October 2018. Disposal of those cylinders is not covered in the garbage management plan.
MARPOL V/ 10.2 50a,c
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2018
Resolved
On ships carrying flammable products a water spray system for cooling, fire prevention, and crew protection should be installed to cover cargo tank domes, cargo liquid lines and vapour manifolds and boundaries of superstructures normally manned. The system should be capable of covering all areas with a uniformly distributed water spray. No water spray was observed from two out of five nozzles and three out of five nozzles had inadequate coverage on tank dome #1, four out of five nozzles were not supplying water spray on tank dome #2, two out of five nozzles were not supplying water spray on tank dome #3, eight out of 11 nozzles were not supplying water spray on the starboard manifold and seven out of the 11 nozzles did not supply water spray on portside manifold.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2018
Resolved
Fire hoses shall, together with any necessary fittings and tool, be kept ready for use. 05 gaskets on 05 fire hoses located in the engine room were observed to be dry-rotted and crumbled to the touch. 74 SOLAS (2014 Ed.) CH. II-2/1-2.3.1.1.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2018
Resolved
On cargo ships, each lifejacket shall be fitted with a lifejacket light. One lifejacket light stored in the portside storage container had an expired lifejacket light. 74 SOLAS (2017 Ed) CH. III / 32.2.2.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 15 August 2018
Resolved
Cargp ships shall carry one or more totally enclosed lifeboats complying with the requirements of section 4.6 of the Code. Normal equipment of every lifeboat shall consist of two bouyant smoke signals. One smoke signal in the portside lifeboat was expired. 74 SOLAS (2014 Ed.) Ch. III/31.1.1.1. ; LSA Code IV/4.4.8.15
Documentation › Certificates/Documents › TVE Letter (CG-840S-1)
Issued 21 August 2008
Resolved
Vessel does not have a valid Sub Chapter "O" Endorsement (SOE). The vessel cannot load or discharge cargo in U.S. waters until a valid SOE is approved by the Marine Safety Center.