← All vessels
ALETHINI
ALETHINI is a 2000 freight ship. The Coast Guard has recorded 16 inspections since 2000, most recently in May 2021, along with 10 deficiencies and 1 operational control.
Records from 2000 to 2021. Most recent: inspection, 31 May 2021.
- Built
- 2000
- Last inspected
- 31 May 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9217826 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7TG4
9765
Flag
MARSHALL ISLANDS
—
Maury page id
psix-9765
Inspections, by type
…with no type recorded3
Years with a record
11 calendar years (2000–2021)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it14458 - Convention (Subpart B), Gross Ton
8760 - Convention (Subpart B), Net Ton
28739 - Displacement, Ton
23677 - Dead Weight, Ton
8760 - Convention (Subpart B), Net Ton
28739 - Displacement, Ton
23677 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
31 May 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7211177
19 May 2021
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7200832
15 July 2018
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6467953
24 January 2018
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6339112
8 July 2017
PII Safety Exam · ISPS II Exam · COE-Offshore · Ballast Water Examination · COE-Administrative
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6194134
22 June 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4350952
19 February 2009
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3418989
15 October 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3080126
13 October 2007
ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3075495
18 July 2006
ISPS II Exam · MARPOL Annex II Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2710554
3 May 2004
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2055350
17 December 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1970905
17 August 2003
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1874193
27 April 2003
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1777928
20 July 2002
Ballast Water Examination · Deficiency Check · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1647407
12 September 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 281983
Deficiency record · 10
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 22 June 2012
Resolved
0730 - The function of the fire detection system shall be periodically tested to the satisfaction of the administration. Vessel does not have proper testing equipment to test heat detectors. the crew is using open flame to test the flame detector.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 22 June 2012
Resolved
0700-In all ships general arrangement plans shall be permanently exhibited, showing clearly for each deck the location of the fire extinguishing appliances. The location of the fire suits are not in the fire plan.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 22 June 2012
Resolved
2120-Each discharge operation or completed incineration shall be completed in the oil record book. The oil record book does not acuretly reflect the actual incineration by the crew.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 22 June 2012
Resolved
0810 - The Safety management system shall be maintained in accordance with the provisions of the international safety management code. crewmember was working over the side the embarkation ladder without wearing a life jacket, in accordance with the vessels ship management system.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 22 June 2012
Resolved
0936 - The steering gear compartment shall be provided with suitable arrangements to ensure working acces to steering gear machinery and controls, which include handrails. The steering compartment does not have handrails that lead from the entrance of the space to the steering gear machinery.
Electrical
Issued 12 September 2000
Resolved
Install insulation or other means on the Emergency Generator exhaust pipingto prevent personnel hazard. SOLAS 74 amd II-1/26.1. Provide class reportprior to next U.S. port.
Electrical
Issued 12 September 2000
Resolved
Install nonconducting mats or gratings in front of Emergency Generator Switchboard. SOLAS 74 amd II-1/45.2. Provide class report prior to next U.S. port.
Lifesaving
Issued 12 September 2000
Resolved
Update new crew familiarization training. STCW 95 A-VI/1. Correct prior to next U.S. port.
Documentation
Issued 12 September 2000
Resolved
Provide valid license for 3rd Officer and 1st Engineer. STCW 95 I/14-1.2. Correct prior to departure.
Navigation
Issued 12 September 2000
Resolved
Investigate Hydraulic Lock Alarm on both steering pumps while operating in emergency mode. SOLAS 74 amd II-1/29. Provide class report prior to next U.S. port.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.