Records from 1991 to 2025. Most recent: inspection, 18 August 2025.
Inspection history · 27
18 August 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8210638
13 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7980626
10 August 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7765909
4 August 2023
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7760014
16 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7655852
27 September 2022
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7567490
30 August 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7547385
30 July 2021
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7272844
2 June 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7213706
2 May 2020
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6956659
7 February 2020
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6921123
16 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6685603
13 May 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6683466
25 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6548107
1 September 2018
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6538878
25 July 2018
Initial Certification · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6490718
20 April 2018
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6400026
11 March 2011
Industry Initiated Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3963577
18 January 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3401723
31 August 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 139218
2 February 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 35761
31 August 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 173231
31 August 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 222054
16 February 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 59285
14 January 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 171325
24 May 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 33738
21 December 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 34949
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 18 August 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. the following must be provided: main engine low lubricating oil pressure; main engine high cooling water temperature. During the vessel's Annual COI Inspection, the operator was unable to provide proof to a Marine Inspector that the engines set-points were tested. Provide proof to a Marine Inspector through a tech-report that the set-points function as intended.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 28 August 2025
Resolution: Recieved tech report for set point testing
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2025
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Wiring enclosure for general alarm light in engine room and generator room were found missing multiple plugs into the enclosure. Vessel is to provide proof of proper plugs installed to the satisfaction of Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 28 August 2025
Resolution: Recveived photos of added plugs where they were missing
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 August 2025
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency light in galley found to be inoperable. Vessel is to make appropriate repairs to the satisfaction of Marine Inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 28 August 2025
Resolution: Recieved photo of newly installed emergency light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2024
Resolved
Propulsion machinery, inlcuding main engines, reduction gears, shafting, bearings, and electrical equipment and systems must: be maintained to ensure proper operation. Marine Inspector observed the port outboard engine improperly operating with a high cooling water temperature alarm. Troubleshoot and rectify alarm on port outboard engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2024
Resolved 23 August 2024
Resolution: - Remove and replace coolant temp sensor.
Clear all codes in ECM memory and run engine to verify
repair. Got engine to operation temp (180F). OK test passed.
Alarm did not sound.
Report in vessel documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 August 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: all bilges and void spaces are kept free from accumulation of combustible and flammable materials annd liquids insofar as practible. Marine Inspector observed an excessive amount of oil accumulation in the forward and midship engine room bilge. Reduce amount of oily bilge to the satisfaction of the inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2024
Resolved 23 August 2024
Resolution: Scheduled bilge pumped for Aug 20 2024. Bilge was pumpied and sprayed with hot water to help clean out the bilge.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 August 2023
Resolved
01 emergency light extinguished.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 8 August 2023
Resolved 4 August 2023
Resolution: Defiency was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 August 2023
Resolved
Oil leak on port inboard engine reduction gear.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2023
Resolved 10 August 2023
Resolution: Recieved photographic evidence of repair.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 August 2023
Resolved
Navigational rules & regulation hand book outdated. Vessel representative provided proof of purchase once defiency was identitfied.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 August 2023
Resolved 4 August 2023
Resolution: Vessel representative provided proof of purchase for updated navigation rules & regulations handbook during inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2022
Resolved
The hoses on the semi portable extinguisher were deteriorated and need to be replaced.
Action required: 10 - Deficiency Rectified
Due 6 September 2022
Resolved 8 September 2022
Resolution: Hoses were replaced IAW mfg. Rcvd photos of new hoses installed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 August 2022
Resolved
The stbd generator has an exhaust leak and the lagging is heavily coated in exhaust soot. Fix exhaust leak and replace lagging as needed.
Action required: 10 - Deficiency Rectified
Due 13 September 2022
Resolved 23 September 2022
Resolution: rcvd photos of newly installed exhaust manifold collector. Engine was test run, no leaks. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 August 2022
Resolved
The panel in the masters cabin has an uncovered opening. Cover opening as per manufacturers instructions.
Action required: 10 - Deficiency Rectified
Due 13 September 2022
Resolved 7 September 2022
Resolution: Rcvd photo of panel with proper blank cover so no openings exist. All sat
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 2 June 2021
Resolved
The charts or maps must be either—
(A) Current editions or currently corrected editions, if the vessel engages in towing exclusively on navigable waters of the U.S., including Western Rivers.
Vessel's bridge computer used as secondary electronic charting system did not have charting program installed. Additionally, crew was unable to demonstrate chart updates on the primary Furuno electronic charting system. Install charting program on computer to fulfill backup requirement and ensure both charting systems have current or currently corrected charts. Provide evidence to the local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 30 July 2021
Resolution: Vessel installed new electrnoic chart system with capability of updates.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 June 2021
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Vessel does not have means to close ventilation serving the machinery space. Install closing device on engine room ventilation and provide evidence to the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 10 June 2021
Resolution: Vessel installed closing devices on engine room ventilation and provided photographic evidence.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 2 June 2021
Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Vessel is missing insulation/guard on port side engine exhaust piping leading up to bridge. Install adequate insulation or guard to protect personnel from burns.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 10 June 2021
Resolution: Vessel installed lagging on exhaust pipes leading up to the wheelhouse and provided photographic evidence.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 June 2021
Resolved
AIS must be maintained in effective operating condition, which includes— The accurate input and upkeep of all AIS data fields and system updates. Vessel's AIS inputs are not current and contain errors. Update data and notify local OCMI when complete.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 4 June 2021
Resolution: Verified AIS inputs have been corrected on NAVCEN website.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 May 2019
Resolved
Fire detection alarm panel indicated power supply failure. Fire Boy technician stated backup batteries needed to be replaced. Tested alarm panel, verified audible and visual alarms were still functional. 8103, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Received receipts for 2 new replacement batteries for the fireboy system.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 May 2019
Resolved
Two portable fire extinguishers located in the engine room were found with broken discharge horns. 7124, 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 16 May 2019
Resolution: Received receipts for 2 new fire extinguisher horns.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018
Resolved
Vsl is broadcasting: No dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2018
Resolved 22 October 2018
Resolution: AIS discrepancy corrected, AIS broadcasting all pertinent information.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 August 2018
Resolved
JD01-Provide required backup or secondary power source for bridge navigation radar.
Action required: 705 - Other - as specified
Due 7 August 2018
Resolved 7 August 2018
Resolution: Vessel owner connected the vessel's backup battery in the wheelhouse to the radar.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 August 2018
Resolved
JD02- Prove required testing of required alarm setpoints for main and auxilary machinery.
Action required: 10 - Deficiency Rectified
Due 1 September 2018
Resolved 13 May 2019
Resolution: Verified low lube oil pressure and high cooling water temp. alarms were installed and tested during annual inspection.