Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
Documentation record
Registered dimensions (L × B × D)34.0 ft × 11.0 ft × 4.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2008
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portMOOSE, WY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
26 May 2026
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319437
27 May 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8106639
28 May 2024
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7922779
30 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7684277
31 May 2022
Drydock Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412198
2 June 2021
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7175775
8 October 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7073860
7 July 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6999893
4 June 2019
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6690443
8 June 2018
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6429957
6 June 2017
Internal Structural Exam · Hull Examination · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6142840
16 May 2016
Special · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5878488
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2024
Resolved
46CFR182.460(a)((1)ii)
An enclosed space containing fuel tanks for gasoline
must have a ventilation system consisting of a
mechanical exhaust system with at least two ventilation
exhaust ducts located at the end of the space opposite
from where the supply ducts are fitted, which extend to
the lowest part of the bilge of the space on each side
of the space, and which are led to one or more exhaust
blowers. Noted that vessel only had one exhaust duct
connected to the mechanical exhaust system. Rectify
within 30 days.
Action required: 705 - Other - as specified
Due 28 June 2024
Resolved 25 June 2024
Resolution: Received evidence that supply ducts were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2024
Resolved
46CFR182.460(e)
Exhaust blower switches must be of the type interlocked
with starting switch and the ignition switch so that the
blowers are started before the starter motor circuit or
engine ignition is energized. Noted there was no
interlock between blower and ignition switch, vessel was
able to operate without blower being energized. Prove
proper operation within 30 days.
Action required: 705 - Other - as specified
Due 28 June 2024
Resolved 14 June 2024
Resolution: Received video of proper operation of the interlock switch.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 June 2021
Resolved
Prove proper servicing of the fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2019
Resolved
Ring Buoy found with deteriorating grab line due to UV degradation. Provide proof of serviceable approved ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 2 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 4 June 2019
Resolved
Relocate the teleaflex boxes so that they do not interfere with the operation of the bilge pump discharge shut-off valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 2 July 2019
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 6 June 2017
Resolved
Ensure a fire retardant foam is installed on the vent closures.
Due 14 July 2017
Resolved 12 July 2017
Engineering › Bilge Water Management System › Pump
Issued 6 June 2017
Resolved
Ensure that the activation of the aft fuel compartment high level bilge alarm does not also energize the forward bilge pump.
Due 7 July 2017
Resolved 7 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2016
Resolved
Ensure the first aid kits item are not expired.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 1 June 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 31 May 2016
Resolved
Tighten the forward fire extinguished retention band bracket.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 1 June 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 31 May 2016
Resolved
Re-secure the Velcro on the #1 natural air vent for the fuel compartment.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 14 June 2016