JENNY LEIGH

JENNY LEIGH is a 2008 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in May 2026, along with 10 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 26 May 2026.

Built
2008
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

977650
Flag
UNITED STATES
Maury page id
psix-977650

Documentation record

Registered dimensions (L × B × D)34.0 ft × 11.0 ft × 4.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2008
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portMOOSE, WY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

26 May 2026 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319437
27 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8106639
28 May 2024 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7922779
30 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7684277
31 May 2022 Drydock Exam · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412198
2 June 2021 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7175775
8 October 2020 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7073860
7 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6999893
4 June 2019 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6690443
8 June 2018 Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6429957
6 June 2017 Internal Structural Exam · Hull Examination · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6142840
16 May 2016 Special · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5878488

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2024 Resolved
46CFR182.460(a)((1)ii) An enclosed space containing fuel tanks for gasoline must have a ventilation system consisting of a mechanical exhaust system with at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted, which extend to the lowest part of the bilge of the space on each side of the space, and which are led to one or more exhaust blowers. Noted that vessel only had one exhaust duct connected to the mechanical exhaust system. Rectify within 30 days.
Action required: 705 - Other - as specified
Due 28 June 2024
Resolved 25 June 2024
Resolution: Received evidence that supply ducts were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2024 Resolved
46CFR182.460(e) Exhaust blower switches must be of the type interlocked with starting switch and the ignition switch so that the blowers are started before the starter motor circuit or engine ignition is energized. Noted there was no interlock between blower and ignition switch, vessel was able to operate without blower being energized. Prove proper operation within 30 days.
Action required: 705 - Other - as specified
Due 28 June 2024
Resolved 14 June 2024
Resolution: Received video of proper operation of the interlock switch.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 June 2021 Resolved
Prove proper servicing of the fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2019 Resolved
Ring Buoy found with deteriorating grab line due to UV degradation. Provide proof of serviceable approved ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 2 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 4 June 2019 Resolved
Relocate the teleaflex boxes so that they do not interfere with the operation of the bilge pump discharge shut-off valves.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 2 July 2019
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 6 June 2017 Resolved
Ensure a fire retardant foam is installed on the vent closures.
Due 14 July 2017
Resolved 12 July 2017
Engineering › Bilge Water Management System › Pump
Issued 6 June 2017 Resolved
Ensure that the activation of the aft fuel compartment high level bilge alarm does not also energize the forward bilge pump.
Due 7 July 2017
Resolved 7 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2016 Resolved
Ensure the first aid kits item are not expired.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 1 June 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 31 May 2016 Resolved
Tighten the forward fire extinguished retention band bracket.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 1 June 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 31 May 2016 Resolved
Re-secure the Velcro on the #1 natural air vent for the fuel compartment.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 14 June 2016