TIMELESS is a 1968 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in July 2025, along with 14 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 25 July 2025.

Built
1968
Last inspected
25 July 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 July 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG4763
Flag
UNITED STATES
Maury page id
psix-97826

Documentation record

Registered dimensions (L × B × D)64.2 ft × 16.0 ft × 4.0 ft
Registered tonnagegross 27 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBURGER BOAT COMPANY INC · MANITOWOC, WI, UNITED STATES · built 1968
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

25 July 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8188997
23 July 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7958469
7 May 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7903296
16 August 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7763259
10 August 2022 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7522146
18 May 2022 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7444419
19 May 2021 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7201025
14 December 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7111274
10 September 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7053157
21 May 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6957026
10 October 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6831865
28 August 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6525068
25 July 2018 Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6490041
1 May 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6403458
13 October 2017 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6288629
10 August 2017 Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6236365
26 July 2017 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6220338
11 October 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6019768
20 April 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5858391

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 July 2025 Resolved
Use of non-approved fire detection systems may be acceptable as excess equipment provided that (1) Components are listed by an independent, nationally recognized testing laboratory as set forth in 29 CFR 1910.7, and are designed, installed, tested, and maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance. Vessel was equipped with 02 expired smoke detectors in the main salon and galley areas. Install new smoke detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2025
Resolved 1 August 2025
Resolution: New smoke detectors were installed onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of non combustible materials with no openings in the sides or bottom. Vessel had plastic receptacles on board. Replace plastic receptacles with non combustible receptacles. 46 CFR 177.405 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2025
Resolved 1 August 2025
Resolution: New non-combustable waste receptacles were placed onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 May 2021 Resolved
Arrangement of a vessel must allow for the safe operation of the vessel giving consideration to provisions for a seaworthy hull. An approximate .5 inch wide by .25 inch deep hole was found in the port shaft housing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Received objective evidence of temp repair as approved. Permanendt repair will be completed NLT 31OCT2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 May 2021 Resolved
For each AC generator, a means for measuring frequency must be provided. There are currently no means to measure frequency for the vessels generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 3 June 2021
Resolution: Installed freequency meter.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 19 May 2021 Resolved
A durable placard must be posted next to all radiotelephone installations with emergency broadcast instructions. There is no emergency broadcast placard at the upper operating station.
Action required: 10 - Deficiency Rectified
Due 19 May 2021
Resolved 19 May 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 October 2019 Resolved
The CO2 distribution line must extend at least 2 inches beyond the last orifice and be closed with a cap or plug. The vessel's distribution line does not extend beyond the last orifice.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 15 October 2019
Resolution: New piping installed to include the 2 inch extension.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 October 2019 Resolved
The COI must be posted under glass or suitable transparent material in a conspicuous place on the vessel where observation by passengers is likely. The vessel's COI is not posted for passengers to see.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 15 October 2019
Resolution: COI posted
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 October 2019 Resolved
The Stability letter shall be posted under glass or other suitable transparent material at the operating station. The vessel's Stability letter is not posted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 15 October 2019
Resolution: Stability Letter posted
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 10 October 2019 Resolved
The EAP hot-line number shall be displayed. The vessel does not have the Employee Assistance Program (EAP) community service hot-line telephone number displayed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 10 September 2020
Resolution: EAP hotline number posted IAW 46 CFR 16.401.
Engineering › Fuel Oil Service System › Ventilation
Issued 1 May 2018 Resolved
Fuel vents did not have 30/30 mesh; install 30/30 mesh by annual inspection. Annual inspection required by 26OCT18.
Action required: 705 - Other - as specified
Due 26 October 2018
Resolved 28 August 2018
Resolution: Installed 4 new fuel vent screens to replace the wasted screens.
Construction/Loadline › Hull › Hull Plating
Issued 26 July 2017 Resolved
Crop and renew hull sections in lazzerette for exhaust and intake ducts, aluminum wasted due to dissimilar metal covers. Complete by 30AOR2018 next D/D; 46CFR176.802.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 30 October 2017
Resolution: Fan was removed and descaled, insulation installed and S/S fan remounted. cleared.
Documentation › Logs/Records › Drug Test Records
Issued 11 October 2016 Resolved
Provide proof of enrollment in drug testing program for all crew members.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 13 October 2016
Resolution: Proof provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 October 2016 Resolved
Provide aspirin for first-aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 13 October 2016
Resolution: Purchased aspirin.
Construction/Loadline › Penetrations › Gasket
Issued 11 October 2016 Resolved
Replace gasket on access hatch on collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 13 October 2016
Resolution: Gasket replaced.