Records from 2016 to 2025. Most recent: inspection, 25 July 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)64.2 ft × 16.0 ft × 4.0 ft
Registered tonnagegross 27 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBURGER BOAT COMPANY INC · MANITOWOC, WI, UNITED STATES · built 1968
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
25 July 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8188997
23 July 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7958469
7 May 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7903296
16 August 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7763259
10 August 2022
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7522146
18 May 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7444419
19 May 2021
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7201025
14 December 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7111274
10 September 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7053157
21 May 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6957026
10 October 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6831865
28 August 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6525068
25 July 2018
Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6490041
1 May 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6403458
13 October 2017
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6288629
10 August 2017
Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6236365
26 July 2017
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6220338
11 October 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6019768
20 April 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5858391
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 July 2025
Resolved
Use of non-approved fire detection systems may be acceptable as excess equipment provided that (1) Components are listed by an independent, nationally recognized testing laboratory as set forth in 29 CFR 1910.7, and are designed, installed, tested, and maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance. Vessel was equipped with 02 expired smoke detectors in the main salon and galley areas. Install new smoke detectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2025
Resolved 1 August 2025
Resolution: New smoke detectors were installed onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of non combustible materials with no openings in the sides or bottom. Vessel had plastic receptacles on board. Replace plastic receptacles with non combustible receptacles. 46 CFR 177.405 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2025
Resolved 1 August 2025
Resolution: New non-combustable waste receptacles were placed onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 May 2021
Resolved
Arrangement of a vessel must allow for the safe operation of the vessel giving consideration to provisions for a seaworthy hull. An approximate .5 inch wide by .25 inch deep hole was found in the port shaft housing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 21 May 2021
Resolution: Received objective evidence of temp repair as approved. Permanendt repair will be completed NLT 31OCT2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 May 2021
Resolved
For each AC generator, a means for measuring frequency must be provided. There are currently no means to measure frequency for the vessels generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 3 June 2021
Resolution: Installed freequency meter.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 19 May 2021
Resolved
A durable placard must be posted next to all radiotelephone installations with emergency broadcast instructions. There is no emergency broadcast placard at the upper operating station.
Action required: 10 - Deficiency Rectified
Due 19 May 2021
Resolved 19 May 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 October 2019
Resolved
The CO2 distribution line must extend at least 2 inches beyond the last orifice and be closed with a cap or plug. The vessel's distribution line does not extend beyond the last orifice.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 15 October 2019
Resolution: New piping installed to include the 2 inch extension.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 October 2019
Resolved
The COI must be posted under glass or suitable transparent material in a conspicuous place on the vessel where observation by passengers is likely. The vessel's COI is not posted for passengers to see.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 15 October 2019
Resolution: COI posted
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 October 2019
Resolved
The Stability letter shall be posted under glass or other suitable transparent material at the operating station. The vessel's Stability letter is not posted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 15 October 2019
Resolution: Stability Letter posted
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 10 October 2019
Resolved
The EAP hot-line number shall be displayed. The vessel does not have the Employee Assistance Program (EAP) community service hot-line telephone number displayed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 10 September 2020
Resolution: EAP hotline number posted IAW 46 CFR 16.401.
Engineering › Fuel Oil Service System › Ventilation
Issued 1 May 2018
Resolved
Fuel vents did not have 30/30 mesh; install 30/30 mesh by annual inspection. Annual inspection required by 26OCT18.
Action required: 705 - Other - as specified
Due 26 October 2018
Resolved 28 August 2018
Resolution: Installed 4 new fuel vent screens to replace the wasted screens.
Construction/Loadline › Hull › Hull Plating
Issued 26 July 2017
Resolved
Crop and renew hull sections in lazzerette for exhaust and intake ducts, aluminum wasted due to dissimilar metal covers. Complete by 30AOR2018 next D/D; 46CFR176.802.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 30 October 2017
Resolution: Fan was removed and descaled, insulation installed and S/S fan remounted. cleared.
Documentation › Logs/Records › Drug Test Records
Issued 11 October 2016
Resolved
Provide proof of enrollment in drug testing program for all crew members.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 13 October 2016
Resolution: Proof provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 October 2016
Resolved
Provide aspirin for first-aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 13 October 2016
Resolution: Purchased aspirin.
Construction/Loadline › Penetrations › Gasket
Issued 11 October 2016
Resolved
Replace gasket on access hatch on collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 13 October 2016
Resolution: Gasket replaced.