MAURY USCG vessel records
← All vessels

PARADERO

PARADERO is a 2007 freight ship. The Coast Guard has recorded 32 inspections since 2016, most recently in March 2026, along with 9 deficiencies and 10 operational controls.

Records from 2016 to 2026. Most recent: inspection, 4 March 2026.

Built
2007
Last inspected
4 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 March 2026
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9368998
979794
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-979794

Documentation record

Tonnage as PSIX records it15455 - Displacement, Metric Ton
11193 - Dead Weight, Metric Ton
4002 - Convention (Subpart B), Net Ton
8246 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

4 March 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8319628
4 February 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8305894
30 September 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8244298
19 September 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8237371
4 September 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8226709
3 September 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8225920
2 March 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8085751
15 August 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7978231
4 February 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7859097
4 November 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7820125
30 July 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7753427
16 July 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7742966
25 January 2023 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7611063
30 March 2022 Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7420937
9 September 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7308045
29 March 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6931323
10 March 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6923071
3 March 2020 PSC A · ISPS Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6917531
24 February 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6912463
9 May 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6683197
29 January 2019 PII Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6616193
14 March 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6371801
24 January 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6341005
21 November 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6310113
17 November 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6308953
16 November 2017 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6307981
15 November 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6308595
21 May 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6151289
1 May 2017 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6136087
20 February 2017 In-Service Inspection · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6091311
29 April 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5865621
21 January 2016 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5801147

Deficiency record · 9

99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 9 September 2021 Resolved
...From the point of view of the safety of life at sea, all ships shall be be sufficiently and efficiently manned. Minimum safe manning document requires 2nd engineer. Does not hold a valid flag state endorsement. 74SOLAS (2020 CONS) V/14.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2021
Resolution: USCG received the Flag State's temporary endorsement for the mariner, confirming reception of the application
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 9 September 2021 Resolved
The capacity in which the holder of a certificate is authorized to serve shall be identified in the form of endorsement. 2nd Eng does not hold a Flag State Endorsement. STCW (17 CONS) I/2.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2021
Resolution: USCG received the Flag State's temporary endorsement for the mariner, confirming reception of the application
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 September 2021 Resolved
Each life raft shall by stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the code. STBD life raft found with painter line not attached to weak link, not allowing for the raft to float free.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
Resolution: Crewmember attached painter line to weak link.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 January 2019 Resolved
07106 - Fire Detection and Alarm System - Fire detection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Smoke detection system for cargo hold one reads a fault, due to faulty pressure switch in line one. Cargo hold smoke detection system was tested and detects smoke properly. 74 SOLAS (14) II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 February 2019
Resolved 12 February 2019
Resolution: A new pressure switch for cargo hold #1 of the smoke detection system was installed. Class survey report attesting to the repairs attached in documents.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 January 2019 Resolved
07108 - Ready availability of fire fighting equipment - Fire protection systems shall be kept in good order so as to ensure their required performance. Deck three starboard side fire hydrant flange burst under pressure while testing fire main. 74 SOLAS (14) II-2/14.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 January 2019
Resolved 29 January 2019
Resolution: A new flange for the fire hydrant was fitted during the PSC inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 January 2019 Resolved
11129 - Operational readiness of lifesaving appliances - Muster and embarkation stations shall be adequately illuminated. Emergency light on deck 2 outside superstructure hospital exit is extinguished, also, numerous other light bulbs are extinguished throughout the ship. 74 SOLAS (14) III/11.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 February 2019
Resolved 14 February 2019
Resolution: Verified delivery receipt for replacement light bulbs.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 16 November 2017 Resolved
1410-shall be provided a crank case oil mist detector. PSC officer found that the crew has been testing the OMD not in accordance with the manufacturers specs. OMD activated causing an engine shutdown while navigating the channel. 74 SOLAS(14) II-1/47
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2017
Resolution: Received report from DNV-GL attesting to the correction of this deficiency
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 16 November 2017 Resolved
The company shall establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. 74 SOLAS (14) IX/3 - ISM Code 10.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 November 2017
Resolution: Crew provided documentation that the SMS had beenupdated to incorporate maintenance schedules for the Oil Mist Detection System.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 1 May 2016 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration. A second source of energy shall be provided unless manual starting can be demonstrated. Secondary battery bank provided for the start of the emergency generator was exhausted and failed to start the emergency generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2016
Resolution: Received DNV-GL report attesting to replacement of depleted batteries and satisfactory testing of new battery bank.

Ownership record