MAURY USCG vessel records Sign in
← All vessels

TRANS FUTURE 7

TRANS FUTURE 7 is a freight ship. The Coast Guard has recorded 21 inspections since 2008, most recently in November 2025, along with 4 deficiencies and 2 operational controls.

Records from 2008 to 2025. Most recent: inspection, 11 November 2025.

Built
Not recorded
Last inspected
11 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9326093 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
981239
Flag
LIBERIA
—
Maury page id
psix-981239

Inspections, by type

…with no type recorded3
Years with a record 12 calendar years (2008–2025)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it14906 - Dead Weight, Ton
18121 - Convention (Subpart B), Net Ton
60401 - Convention (Subpart B), Gross Ton
60401 - Simplified, Gross Ton
18121 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

11 November 2025 Deficiency Check · PSC B
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8264941
1 October 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8244597
25 September 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8240867
27 April 2025 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8121099
29 May 2024 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7918352
27 September 2023 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7799610
25 July 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7752338
18 April 2023 PSC B
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7667607
9 August 2022 PSC B · ISPS Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7525228
4 November 2021 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7341720
24 February 2021 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7143851
30 July 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6762483
17 July 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6480388
19 July 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6207198
5 July 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5924280
11 April 2016 ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5852079
29 August 2014 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4968459
1 May 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4847782
1 January 2011 PII Safety Exam · STCW 95 Exam · MARPOL Annex V Examination · Ballast Water Examination · ILO-147 Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3918652
28 October 2008 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3352638
9 September 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3316492

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 November 2025 Resolved
17(AC)- 07106- A fixed fire detection and alarm system shall be provided in accordance with the provisions of this regulation. The crew identified a fault and total system malfunction of the Autrosafe Fire Detection System, used to detect fires onboard in accommodation spaces, cargo spaces and engine room. The crew detected the fault on November 11, 2025 and arrived in Saipan on the same day. The last satisfactory test and record for the test was on November 9th, 2025. The keyboard at the panel on the bridge is inoperable. The Captain initiated a 3-person roving watch for the cargo spaces and the engine room is fully manned on a 24 hour watch rotation until the deficiency is rectified. SOLAS 74 (2004 Cons ed) Ch II-2 Reg 7.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2025
Resolved 16 November 2025
Resolution: Vessel Captain supplied technicians report to the CG inspectors attesting the fire detection system is fully operational and a letter from the Classification society accepting the repairs.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 May 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 May 2024
Resolved 18 July 2024
Resolution: Review Class Report, Satisfactory.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 May 2024 Resolved
FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE PROPERLY TESTED AND INSPECTED. THE DRY POWDER PORTABLE FIRE-EXTINUISHE IN THE EMEGENCY GENERATOR ROOM HAS NOT BEEN PROPERLY INSPECTED FOR THE MONTHS OF APRIL AND MAY OF 2024 74SOLAS04 II-2/14.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2024
Resolved 27 February 2025
Resolution: Reviewed Class Report, Satisfactory.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 9 September 2008 Resolved
Non-tank vessel response plan does not list Guam as an approved COTP Zone.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 October 2008
Resolution: NTVRP lists Guam as approved zone. As verified by fax.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.