MAURY USCG vessel records
← All vessels

UMM LAQHAB

UMM LAQHAB is a 2008 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in March 2026, along with 10 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 31 March 2026.

Built
2008
Last inspected
31 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9359454
981887
Flag
MARSHALL ISLANDS
Maury page id
psix-981887

Documentation record

Tonnage as PSIX records it54538 - Dead Weight, Metric Ton
73662 - Displacement, Metric Ton
47058 - Convention (Subpart B), Gross Ton
15944 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

31 March 2026 Administrative Inspection · COC-GAS Annual
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8338859
14 January 2025 COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8063556
7 February 2024 Administrative Inspection · COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7862036
12 December 2022 PSC B · Deficiency Check · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7599481
12 August 2021 PSC B · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7284761
19 July 2020 Administrative Inspection · COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7009317
21 June 2019 Administrative Inspection · COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6705434
25 March 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6648907
6 September 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6534395
22 June 2018 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6434403
4 May 2017 Deficiency Check · ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6138950
9 March 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6101858
5 May 2016 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5858364

Deficiency record · 10

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 December 2022 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. The forward most deck light on the catwalk has a removed wire allowing an opening to the housing. 74 SOLAS (04) II-1/40
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 December 2022
Resolved 12 December 2022
Resolution: Vessel's Electrical Officer installed a cap over the opening of the light housing.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 December 2022 Resolved
A gas carrier shall comply with the requirements of the International Gas Carrier Code. Emergency shutdown valves in liquid piping should fully close under all service conditions with 30s of activation. Port State Control Officers 50s closure. 74 SOLAS (04) VII/13 IGC 93/5.6.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2022
Resolved 12 December 2022
Resolution: Ships crew adjusted the closure devices to 26 seconds.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 12 December 2022 Resolved
On ships carrying flammable or toxic products, as water spray system for cooling, fire prevention, and crew protection should be installed to cover exposed cargo tank domes are exposed parts of tanks. Port State Contol Officers observed 10 partially clogged nozzles; 02 on #1 tank, 02 on #2 tank, 02 on port manifold, 01 on #3 tank, and 03 on stbd man.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2022
Resolved 12 December 2022
Resolution: Ship crew cleaned the blocked nozzles.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2022 Resolved
Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations. To avoid the possibility of dangerous sparking between metallic parts in the event of an electrical fault, exposed and extraneous conductive parts, other than those exempted by 5.4.2, are to be connected to earth. Port State Control Officers observed 03 lighting fixtures with missing or broken bonding wires, 01 at the base of superstructure and 02 at tank #4. 74 SOLAS (04) 11-1/40 IEC 60092.502 5.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2022
Resolved 12 December 2022
Resolution: Ship tech added earth grounding cable to 03 lighting fixtures.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 June 2019 Resolved
Deficiency Code - 07110 Deficiency Category – Fixed fire fighting On ships carrying flammable or toxic products or both, a water spray system for cooling, fire prevention and crew protection should be installed to cover cargo liquid and vapour discharge and loading manifolds. Seven of the ten deck water spray nozzles designed to cover the port side cargo loading/discharge manifold are blocked rendering the system incapable of providing sufficient coverage for the manifold. Deficiency Cite/Regulation - 74SOLAS(14)VII/13.1 - 93 IGC Code 11.3.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 August 2019
Resolved 24 June 2019
Resolution: Received, reviewed and accepted class report / proper documentation from DNV-GL and master stating the deficiency was rectified. Vessel crew removed water spray heads from port manifold line, flushed port manifold line and re-installed water spray heads.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 22 June 2018 Resolved
While testing automatic closures of the liquid fill valve on the #4 cargo tank, examiners found the port liquid fill valve did not close automatically after actuating high level alarm. SOLAS VII/13.1 IGC (93) 13.3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2018
Resolved 24 June 2018
Resolution: Rectified with Class Survey Report
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 22 June 2018 Resolved
During PSC examination, found STBD side ESD foward liquid valve was not working. SOLAS VII/13.1 IGC (93) 5.6.4
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2018
Resolved 24 June 2018
Resolution: Rectified with Class Survey Report
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 22 June 2018 Resolved
While testing gas detector with 35% LEL propane, the read out stabilized at 27% LEL. Witnessed proper calibration but testing from within the gas detection cabinet never went above 27% LEL. SOLAS VI/13.1 IGC (93) 13.6.6
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2018
Resolved 24 June 2018
Resolution: Rectified with Class Survey Report
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 4 May 2017 Resolved
1199-Pressure relief valves should be set and sealed by a competent authority acceptable to the administration and a record of this action, including the values of set pressure should be retained aboard the ship. Vessel has documentation from Middle East Fuji Engineering LLC attesting to safety relief valves testing dated 12APR2013. Classification society approval not listed on documentation. 74
Due 5 June 2017
Resolved 16 May 2017
Resolution: Vessel provided proper documentation attesting to the set and sealing of the MARVS. Attached to MISLE #6138950.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 4 May 2017 Resolved
1850-Water-spray system on ships carrying flammable or toxic products or both, a water spray system for cooling, fire prevention and crew protection should be installed. Installed system did not provide adequate coverage of the #1 cargo tank top. 74 SOLAS(04) VII/12, IGC 11.3
Condition: Improper/Lack of Maintenance
Due 5 May 2017
Resolved 5 May 2017
Resolution: To satisfaction to attending Coast Guard Inspectors

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.