TASING SWAN is a 2007 tank ship. The Coast Guard has recorded 31 inspections since 2016, most recently in April 2024, along with 7 deficiencies and 1 operational control.
Records from 2016 to 2024. Most recent: inspection, 19 April 2024.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it15164 - Displacement, Metric Ton 11336 - Dead Weight, Metric Ton 7232 - Convention (Subpart B), Gross Ton 3643 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
31 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 31
19 April 2024PSC B · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7896874
7 December 2023COC-CHEM & TVE Annual · Administrative Inspection · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7834501
2 December 2022COC-CHEM & TVE Renew · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7603048
17 July 2022Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7510201
17 July 2022Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7511153
21 December 2021Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7371241
3 December 2021PSC B · COC-CHEM & TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7359269
15 December 2020Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7112369
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 April 2024Resolved
Every inflatable liferaft shall be serviced at intervals not exceeding 12 months, provided where in any case this is impracticable, the administration may extend this period to 17 months. 2 out of 3 inflatable liferafts have not been serviced within the past 12 months. Administration has not extended this period to 17 months.
74 SOLAS (20) III/20.8.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2024
Resolved 21 April 2024
Resolution: Provided satisfactory class report and flag letter to clear deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 December 2022Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The ship had 01 inoperable lifebuoy light and 03 of its lifebuoys were tied to the vessel and not ready for immediate use.
Action required: 10 - Deficiency Rectified
Due 2 December 2022
Resolved 2 December 2022
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 3 December 2021Resolved
Acceptable types of water seals include the wet and semi type. other types of seals may be accepted on a case by case basis if approval is given by the Coast Guard Marine Safety Center. Vessel could not provide MSC approval letter for dry type deck seal.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 21 December 2021
Resolution: Received the required approval letter from MSC, approving the vessel's isntalled dry-type deck seal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 November 2020Resolved
PSCO witness no jacketing on the high pressure fuel line. They were removed in dry dock.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2020
Resolved 10 December 2020
Resolution: Received class report attesting to the repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 28 November 2020Resolved
Required calibration of oxygen analyzer was conducted with expired cal gas. New bottle was provided.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 November 2020
Resolution: New bottle was provided
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 8 February 2016Resolved
The operator of a vessel with a capacity of 250 or more bbls of oil, HAZMAT or liquified gas... shall provide transfer procedures that meet the requirements of 33CFR155.750. PSCO found vessel does not possess transfer procedures encompassing the requirements of 33CFR155.750 for both cargo and bunker.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2016
Resolved 10 February 2016
Resolution: Deficiency Corrected on the spot. 10c
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 8 February 2016Resolved
A tank over-flow control system required by this section shall: give a visual and audible tank-overflow alarm to the ship's operator. PSCO found visual deck alarm for overfill inoperable.
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 10 February 2016
Resolution: Deficiency Corrected on the spot. 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.