MAURY USCG vessel records
← All vessels

XIN MEI ZHOU

XIN MEI ZHOU is a 2008 freight ship. The Coast Guard has recorded 22 inspections since 2016, most recently in August 2025, along with 5 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 24 August 2025.

Built
2008
Last inspected
24 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 August 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9337925
982380
Flag
CHINA
Maury page id
psix-982380

Documentation record

Tonnage as PSIX records it102396 - Dead Weight, Ton
137288 - Displacement, Ton
90757 - Convention (Subpart B), Gross Ton
57364 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

22 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

24 August 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8216708
26 March 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8099802
18 January 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8067348
4 January 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8057474
4 November 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8029047
27 October 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8025209
22 August 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7982605
21 August 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7985984
11 April 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7893668
20 November 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7827769
10 August 2023 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7764650
29 June 2023 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7724551
11 April 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7664667
7 April 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7664618
25 December 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7612904
19 December 2022 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7607213
16 December 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7610251
15 December 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7609455
15 December 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7609621
14 December 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7608959
8 August 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6234016
13 July 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5939092

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 August 2024 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliabilty of fire-fighting systems and appliances. PSCO observed time-delay bottles had not been tested in accordance with MSC.1/Circ.1318. 74SOLAS(20) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2024
Resolution: received class/tech reports from CCS and Delmarsafety
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 29 June 2023 Resolved
07122 - Fire Safety - General arrangement plans shall be permanently exhibited for the guidance of the ship's officers. PSCO observed discrepancies between fire plan and muster list regarding number and location of muster stations on board. 74 SOLAS (04) II-2/15.2.4.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 August 2023
Resolution: Vessel updated the muster list and changed muster stations to coordinate with the number and location marked on the fire plan, and carried out extensive drills with the crew
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 June 2023 Resolved
11117 - Life Saving Appliances - Not less than one half of the total number of life buoys shall be provided with life buoy self igniting lights compliant with requirements of paragraph 2.1.2 of the Code. PSCO observed inoperable buoy light. 74 SOLAS (20) III/7.6.3
Action required: 10 - Deficiency Rectified
Resolved 29 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 December 2022 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. Vessel's no. 2 generator is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 April 2023
Resolution: During dry dock tech found and repaired damaged insulation on the rotor windings.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 8 August 2017 Resolved
1599, 74SOLAS(14) V/20.1, 17ac, TO ASSIST IN CASUALTY INVESTIGATIONS, SHIPS, WHEN ENGAGED ON INTERNATIONAL VOYAGE, SUBJECT TO PROVISIONS OF REG 1.4 SHALL BE FITTED WITH A VOYAGE DATA RECORDER. SHIP REPORTED ON NOA THAT SHIP'S VDR COMPUTER WILL NOT START.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2017
Resolved 9 August 2017
Resolution: Tech report received states: Replacement computer was installed in place of the damaged HP7100. After testing, the system is back to operation as designed and is compliant.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.