MAURY USCG vessel records Sign in
← All vessels

CAPTAIN NICHOLAS ML

CAPTAIN NICHOLAS ML is a 2008 tank ship. The Coast Guard has recorded 8 inspections since 2015, most recently in May 2019, along with 4 deficiencies and 1 operational control, 1 with no removal date recorded.

Records from 2015 to 2019. Most recent: inspection, 29 May 2019.

Built
2008
Last inspected
29 May 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9351919 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
983977
Flag
BAHAMAS, THE
—
Maury page id
psix-983977

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2015–2019)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it47173 - Convention (Subpart B), Gross Ton
17309 - Convention (Subpart B), Net Ton
77523 - Displacement, Ton
58670 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

29 May 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6698468
25 March 2019 ISPS II Exam · COC-GAS Renew · PII Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6646573
20 March 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6646174
18 January 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6340025
11 June 2017 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6161546
11 June 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6296106
18 December 2015 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5784627
14 December 2015 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5770947

Deficiency record · 4

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 26 March 2019 Resolved
The Company should establish procedures, plans, and instructions including checklists as appropriate for key shipboard operations concerning protection of the environment. Ship’s SMS makes reference to mepc 60(33) and the vessel has a mepc 107(49) Separator and OCM (Oil Content Meter). Sample line on OWS is required to be painted bright orange or yellow and is not painted. Crew added colored tape when overhearing PSCO discussing. Sample line required to be painted per SMS. SMS makes reference to Oily Water Separator Record and to Section 15 of the SMS Manual. Crew cannot find those items. Due to PSCO observations, an Audit by the ISM SMC issuing authority is recommended to be completed in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 May 2019
Resolution: Vessel provided audit report see attached.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 25 March 2019 Resolved
The arrangement on board the ship for the extraction of samples from the 15 ppm bilge alarm should give a truly representative sample of the effluent with adequate pressure and flow. PSCO observed a valve on the sample extraction line. This valve does not appear on the posted ship’s diagram. PSCO was unable to verify operation of system due to quality of water in bilge holding tank. Check valve leading to bilge tank malfunctioned allowing water to back up into containment and subsequently overflowed. Prove operation of OWS system and prove validity of presence of valve on sampling line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2019
Resolution: DNV-GL attended vessel and removed valve in OCM sample line and provided Class documentation attesting to the satisfactory installation and operation of the OWS and OCM.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 11 June 2017 Resolved
All vessels equipped with ballast water tanks that operate in US waters must remove fouling organisms from the hull on a regular basis. Correct to the satisfaction of USCG. 33CFR151.2035(a)(6)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 May 2019
Resolution: Completed satisfactory exam and found no discrepancies
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 15 December 2015 Resolved
Pressure relief valves should be set and sealed by a competent authority acceptable to the Administration and a record of this action, including the valves of set pressure, should be retained aboard the ship.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2016
Resolution: Received service report from [name withheld] attesting to repair and sealing of safety relief valves. - JB

Ownership record