MAURY USCG vessel records Sign in
← All vessels

FALCON MAJESTIC

FALCON MAJESTIC is a tank ship. The Coast Guard has recorded 15 inspections since 2008, most recently in October 2024, along with 3 deficiencies and 3 operational controls.

Records from 2008 to 2024. Most recent: inspection, 9 October 2024.

Built
Not recorded
Last inspected
9 October 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9374284 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V5389
984014
Flag
HONG KONG
—
Maury page id
psix-984014

Inspections, by type

…with no type recorded5
Years with a record 8 calendar years (2008–2024)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29266 - Convention (Subpart B), Gross Ton
12026 - Convention (Subpart B), Net Ton
47128 - Dead Weight, Ton
56280 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

9 October 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8016682
18 February 2017 ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6088113
10 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6086289
10 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6086293
25 August 2016 Deficiency Check · COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5978575
9 September 2015 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5232209
20 January 2012 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4228356
20 January 2012 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4229669
18 December 2011 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4211970
6 December 2011 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4202425
29 September 2011 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4153074
16 July 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4083577
28 September 2010 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3858676
15 September 2010 ISPS III Exam · Ballast Water Examination · NPV Safety Exam · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3850250
21 September 2008 COC-CHEM Renew · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex II Examination · MARPOL Annex V Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3329224

Deficiency record · 3

Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 25 August 2016 Resolved
Vessel found to possess an inoperable ODME per this regulation since 13 AUG 2016. A dispensation from Flag for aforementioned equipment is onboard to expire in October 2016.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 September 2016
Resolved 29 August 2016
Resolution: Vessel provided a survey from their class (American Bureau of Shipping) stating the vessel was found to be in compliance with MARPOL Annex I.
Lifesaving › Lifeboat › Propulsion Engine
Issued 9 September 2015 Resolved
The engine shall be capable of operating for not less than 5 min after starting from cold with lifeboat out of the water. The vessel's free-fall lifeboat engine was not able to start.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 9 September 2015
Resolution: rectified on the spot.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 December 2011 Resolved
X-BAND RADAR IS INOPERATIVE.
Action required: 705 - Other - as specified
Due 2 January 2012
Resolved 20 January 2012
Resolution: TECH REPORT FROM MACKAY COMMUNICATIONS VERIFIED PROPER OPERATION OF THE X-BAND RADAR.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.