← All vessels
NAPLES PRINCESS
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named NAPLES PRINCESS
NAPLES PRINCESS is a 2008 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2008, most recently in September 2025, along with 30 deficiencies and 5 casualty investigations between 2012 and 2019.
Records from 2008 to 2025. Most recent: inspection, 22 September 2025.
- Built
- 2008
- Last inspected
- 22 September 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 30 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2012–2019
Identity
1215777
WDL2334
984092
Flag
UNITED STATES
367388160
Maury page id
psix-984092
Inspections, by type
…with no type recorded2
Years with a record
16 calendar years (2008–2025)
The 38 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)95.3 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)95.3 ft × 24.0 ft × 6.0 ft
ITC tonnagegross 264 / net 85
BuilderSKIPPER FABRICATING LLC · LACROSSE, WI, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNAPLES, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 29 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
264 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
85 - Convention (Subpart B), Net Ton
264 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
85 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL2334MMSI 367388160 · active · compulsorily equipped · granted 30 August 2019, expires 30 August 2029
WDE7039MMSI 367388160 · expired · compulsorily equipped · granted 17 December 2008, cancelled 16 February 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 38
22 September 2025
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8237310
7 October 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8014605
17 September 2024
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8003434
18 September 2023
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7793491
14 November 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7592129
18 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579559
19 September 2022
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7560295
7 December 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7363349
28 July 2021
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7270677
30 November 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7092159
10 October 2020
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7077102
23 September 2020
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7063592
15 September 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7057507
21 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6836273
26 August 2019
Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6795236
9 August 2019
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6777803
15 January 2019
Inclining Experiment · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6608338
29 October 2018
Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6570426
5 September 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6531790
22 January 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6340448
8 August 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6222725
25 July 2017
In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6205533
14 November 2016
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6028381
5 January 2016
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5779842
15 September 2015
Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5215985
6 May 2014
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4809670
4 March 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4811278
3 June 2012
Damage Survey · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4348102
23 January 2012
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4228480
5 December 2011
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4201971
10 August 2011
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4111300
27 July 2011
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4095869
31 January 2011
Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3934384
6 December 2010
In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3904891
12 October 2010
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3864808
1 February 2010
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3673254
16 December 2008
Administrative Inspection · Initial Certification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3376475
3 March 2008
Hull Examination · Drydock Exam · Inclining Experiment · Plan Review "T" Boat · Construction Oversight · COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3336768
Deficiency record · 30
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 26 August 2019
Resolved
FCC Station Authorization is expired; renew station authorization. In accordance with 47CFR80.933, the vessel is limited to not more than 1,000 feet from shore.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 8 August 2017
Resolved
Replace CO2 signage in bottle space to reflect requirements of 46CFR185.612(g)
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 8 August 2017
Resolved
Replace CO2 signage in engine room to reflect requirements of 46CFR185.612(g)
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 November 2016
Resolved
Bilge alarms are going off randomly, make round of spaces until alarm panel is fixed.
Operations/Management › Vessel Activity › Other
Issued 14 November 2016
Resolved
Galley has food and other items on floor, especially under appliances, clean galley.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 November 2016
Resolved
Replace fire extinguisher bracket on top deck.
Fire Fighting › Fire Hoses › Material
Issued 14 November 2016
Resolved
Prove hose approval to UL19 or Commandant approved equivalent.
Navigation › Piloting/Steering › Marine Charts
Issued 5 January 2016
Resolved
Coast pilot and chart are out of date. Provide current coast pilot and chart on board.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 5 January 2016
Resolved
Humidifiers in A/C and tank spaces are not hardwired. Hard wire permanently affixed humidifiers.
Stability › Weathertight Integrity › General
Issued 5 January 2016
Resolved
Second deck aft door will not close completely. Prove proper operation of door latch
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 January 2016
Resolved
FWD A/C pump has crack in housing, repair/replace.
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 January 2016
Resolved
Aft A/C pump PVC fitting is leaking, repair / replace.
Engineering › Bilge Water Management System › Not Operational
Issued 5 January 2016
Resolved
Prove proper operation of auxiliary bilge pump. Provide alternate plan for secondary bilge pump to meet compliance.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 September 2015
Resolved
Hardwire all equipment identified during internal structural exam, IAW 46 CFR 183.340(r) & 111.60-13.
Construction/Loadline › Structures › Superstructure
Issued 3 June 2012
Resolved
Repair/Replace broken window forward IAW 46 CFR 177.1010.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 31 January 2011
Resolved
Install a fuel strainer bowl that is resistant to shattering, IAW 46CFR182.455(b)(6). Shall be completed prior to 06FEB11.
Communications › Radio Communications › EPIRB
Issued 31 January 2011
Resolved
Replace expired hydrostatic release for EPIRB IAW 46CFR180.64. Shall be completed prior to operating past line of demarcation.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 February 2010
Resolved
Replace expired items in first aid kit.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 February 2010
Resolved
Post life jacket donning placard.
Engineering › Fuel Oil Service System › Portable Fuel System
Issued 22 February 2010
Resolved
Remove portable fuel tank from machinery space.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 February 2010
Resolved
Repair emergency light in galley.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 December 2008
Resolved
Provide servicing report for the fixed fire fighting system in the galley fryer.
Communications › Radio Communications › EPIRB
Issued 16 December 2008
Resolved
[name withheld] with vessel name.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 16 December 2008
Resolved
Provide additional fire extinguisher for the 02 deck.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 16 December 2008
Resolved
Mark upper decks with maximum passenger capacity per the stability letter
Personnel › Training › Safety Orientation
Issued 16 December 2008
Resolved
Post station bill.
Operations/Management › Pollution › Control of Garbage
Issued 16 December 2008
Resolved
Post waste management plan.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 October 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › Stability Letter
Issued 16 October 2008
Resolved
Obtain a valid Stability letter for the vessel; to be issued by USCG Marine Safety Center.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 October 2008
Resolved
Procure Man Overboard davit block & tackle and rescue harness, and conduct Man overboard, fire, flooding & abandon ship drills in presence of CG Marine Inspector as items were not verified during the initial delivery inspection.
Casualty record · 5
22 October 2012Routine · role: Involved in a Marine Casualty · activity 4474234
25 November 2013Routine · role: Involved in a Marine Casualty · activity 4813938
17 January 2014Routine · role: Involved in a Marine Casualty · activity 4814128
4 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4811278
9 August 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6777803
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.