MAURY USCG vessel records Sign in
← All vessels

CAP CAPRICORN

CAP CAPRICORN is a freight ship. The Coast Guard has recorded 7 inspections since 2008, most recently in November 2010, along with 1 deficiency and 2 operational controls.

Records from 2008 to 2010. Most recent: inspection, 9 November 2010.

Built
Not recorded
Last inspected
9 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9330549 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
984616
Flag
LIBERIA
—
Maury page id
psix-984616

Inspections, by type

…with no type recorded4
Years with a record 3 calendar years (2008–2010)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it14769 - Convention (Subpart B), Net Ton
28616 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

9 November 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3885906
9 November 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3887725
14 March 2009 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3433286
23 December 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3384055
22 December 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3383855
22 December 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3386488
27 September 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3333762

Deficiency record · 1

Electrical › Electric Supply System (service) › Overcurrent Device
Issued 23 December 2008 Resolved
0950- (Electrical equipment in general)- Vessel experienced a loss of power, due to suspected electrical short of the reefers power supply system. Electrical installation shall be such that electrical services essential for safety, will be ensured under various emergency conditions. SOLAS 74 2004 Cons.CH. II- I Reg.40.1
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 7 January 2009
Resolution: Class survey report and Tech report received. Coast Guard verified repair of power transformers.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.