← All vessels
ANGUS EXPRESS
Freight Ship · General Dry Cargo Ship class · USCG Northwest District (CGD-NW) · Other hulls named ANGUS EXPRESS
ANGUS EXPRESS is a freight ship. The Coast Guard has recorded 13 inspections since 2008, most recently in June 2017, along with 3 deficiencies and 7 operational controls.
Records from 2008 to 2017. Most recent: inspection, 22 June 2017.
- Built
- Not recorded
- Last inspected
- 22 June 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9167057 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DUYJ
985520
Flag
PHILIPPINES
—
Maury page id
psix-985520
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it4752 - Convention (Subpart B), Gross Ton
2692 - Convention (Subpart B), Net Ton
2692 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
22 June 2017
PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6171111
8 May 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4305138
8 May 2012
Ballast Water Examination · PI Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4305204
8 May 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4305693
26 August 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4127750
3 August 2011
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4103870
18 January 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3928668
22 October 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3875066
19 October 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3873264
19 October 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3873265
23 October 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3349982
23 October 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3350049
21 October 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3348945
Deficiency record · 3
Documentation › Certificates/Documents › IOPP Certificate
Issued 3 August 2011
Resolved
0150 - Oil Pollution Prevention - The vessel is equipped with an oil content meter that does not match the one documented in the vessel's IOPP certificate. MARPOL 73/78 (2006 Cons. Ed.) Vessel to correct documentation to the satisfaction of class.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 23 October 2008
Resolved
Vessels emergency generator primary and secondary means of starting was found inoperable. The vessel shall submit a classification report from the certificate issuing authority attesting to the full and safe operation of the vessel's emergency starting arrangements.
Documentation › Logs/Records › Oil Record Book
Issued 23 October 2008
Resolved
Vessel was unable to provide 3 years of oil record book entries. The vessel shall be readily available for the previous 3 years in oil record book entries.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.