← All vessels
MSC QINGDAO
MSC QINGDAO is a 2004 freight ship. The Coast Guard has recorded 46 inspections since 2008, most recently in January 2026, along with 47 deficiencies and 11 operational controls.
Records from 2008 to 2026. Most recent: inspection, 2 January 2026.
- Built
- 2004
- Last inspected
- 2 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 47 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9256470 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5UA5
986334
Flag
LIBERIA
—
Maury page id
psix-986334
Inspections, by type
…with no type recorded16
Years with a record
10 calendar years (2008–2026)
The 46 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it89097 - Convention (Subpart B), Gross Ton
59065 - Convention (Subpart B), Net Ton
139771 - Displacement, Ton
105185 - Dead Weight, Ton
59065 - Convention (Subpart B), Net Ton
139771 - Displacement, Ton
105185 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 46
2 January 2026
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8289171
30 December 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8288330
19 August 2025
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8213413
7 June 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8153656
6 June 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8153034
3 June 2025
Deficiency Check · PSC A · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8150699
31 May 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8148816
30 May 2025
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8148324
27 May 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8144772
21 March 2024
PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7881136
18 March 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7880811
17 March 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7880826
17 March 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7880831
16 March 2024
PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7879586
13 March 2024
Administrative Inspection · PSC B · ISM Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7878722
26 January 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7855951
12 January 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7848744
29 November 2023
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7830551
21 November 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7827980
4 March 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7645466
4 December 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604010
30 November 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7602102
27 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7566979
21 September 2022
PSC C
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7563399
24 August 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7542161
16 August 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7535134
11 August 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7530608
30 October 2021
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7341795
29 October 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7341852
20 October 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7336489
15 August 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7287312
11 August 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7283783
31 May 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7211747
27 May 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7208394
5 April 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7168831
3 April 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7168018
1 April 2021
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7167350
26 March 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7163412
12 March 2021
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7154611
9 March 2021
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152570
15 April 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6387119
3 March 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4803851
29 May 2012
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4316209
10 October 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3341720
8 October 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3341113
5 October 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3339121
Deficiency record · 47
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 December 2025
Resolved
Emergency generating sets shall be capable of being readily started in their cold condition at a temperature of 0*C. If this is impracticable, or if lower temperatures are likely to be encountered, provision acceptable... shall be made for the maintenance of heating arrangements, to ensure ready starting of generating sets. 74SOLAS (04) I-1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 June 2025
Resolved
To prevent ignition of combustible materials or flamable liquids....means shall be provided to control leaks of flamable liquids.
PSCO observed leaking fuel oil from the #7 and #8 fuel injectors on the main engine.
74SOLAS(09)II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 June 2025
Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons onboard. PSCO reported significant lubricating and fuel oil leaks throughout the engine room and across all three operational generators. Specifically, excessive oil was observed in the following areas: beneath the aft door in the purifier room, near and around the v/v remote system, leaking from the gauge on the No. 2 M/E F.O. Circ Pump Discharge, under and surrounding the No. 1 H.F.O. Purifier, around and beneath circulator #2, near the lagging of the No. 5 H.F.O. Purifier and underneath the purifier itself. Additionally, fuel had accumulated beneath the covers of each operating generator, with oil pooling on and around each of the generators.
74 SOLAS (2004) II-2/4.2.3.2.3.1
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 3 June 2025
Resolved
Machinery shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces. Missing parts of lagging on #4 generator exhaust manifold at expansion joint.
74 SOLAS (20) II-1/26.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 June 2025
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions, and for this purpose tests for tightness shall be required at the initial survey, and may be required at periodical surveys and at annual inspections or at more frequent intervals. PSCO Observed distorted and damaged cargo hatch tie down points on cargo hold #1 port aft, #3 port aft, #4 aft starboard.
1966 ILLC Reg 16 (4)
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 3 June 2025
Resolved
A hazmat employee must receive the training required by this subpart at least once every three years. PSCO observed the vessels second mate last 49 CFR training was in 2018 and 2017 respectively.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 30 May 2025
Resolved
External high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high pressure line failure. A jacketed pipe incorporates an outer pipe into which the high pressure fuel pipe is placed, forming a permanent assembly. The pressure piping system shall include a means for collection of leakages and arrangements shall be provided with an alarm in case of a fuel line failure. Vessels MDE #5 cylinder has a high-pressure fuel line ruptured and excessive F/O leak.
74SOLAS(09)II-2/4.2.2.5.2
60ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2025
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed vessel's MDE had excessive leakage from the cooling water inlet piping on cylinders #3 and #5.
74SOLAS(04)II-1/26.1
60ac
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 May 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessels starboard lifeboat/rescue boat's battery was dead and it was unable to start.
74SOLAS(24)III/20.2
17c
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 30 May 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire-extinguisher in the purifier room was found with a broken gauge. Crew replaced extinguisher in kind.
74SOLAS(24)II-2/14.2.1.2
10c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2025
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed vessel's MDE had excessive leakage from the cooling water inlet piping on cylinders #3 and #5. Vessel made temporary repairs with a Condition of Class issue until 13JUN25
74SOLAS(04)II-1/26.1
50ac
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 May 2025
Resolved
EACH EMERGENCY GENERATING SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH STARTING DEVICES APPROVED BY THE ADMINISTRATION WITH A STORED ENERGY CAPACITY OF AT LEAST THREE CONSECUTIVE STARTS. A SECOND SOURCE OF ENERGY SHALL BE PROVIDED FOR AN ADDITIONAL THREEWITHIN 30 MIN. UNLESS MANUAL STARTING CAN BE DEMONSTRATED TO BE EFFECTIVE. PSCO OBSERVED SHIP'S CREW TRY TO START EDG WITH HYDRAULIC ACCUMULATOR. EDG DID NOT STQART UPON ACCUMULATION OF THE HYDRAULIC ACCUMULATOR.
74SOLAS(04)II-1/44.2
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 May 2025
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING REQUIREMENTS SHALL BE MET: (.1)MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS; (.2)ACCUMULATION OF FLAMMABLE VAPOURS; (.3) THE IGNIGHTABILITY OF COMBUSTABLE MATERIALS SHALL BE RESTRICTED; (.4) IGNITION SOURCES SHALL BE RESTRRICTED; MULTIPLE AREAS OF OIL-SOAKED, DEGRADED LAGGING, OIL LEAKS AND POOLING OBSERVED ON THE MAIN ENGINE BLOCK IN VARIOUS LOCATIONS.
74SOLAS(04) II-2/4.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 21 March 2024
Resolved
THE COMPANY SHOULD ENSURE THAT ALL PERSONNEL INVOLVED IN THE COMPANY'S SAFETY MANAGEMENT SYSTEM HAVE AN ADEQUATE UNDERSTANDING OF RELEVANT RULES, REGULATIONS, CODES AND GUIDELINES. LOCK OUT / TAG OUT PROCEDURES ARE CLEARLY INCORPORATED INTO THE SHIPBOARD SMS, PSCO OBSERVED LOCK OUT / TAG OUT PROCEDURES WERE NOT FOLLOWED FOR INOPERABLE MAIN ENGINE LUBE OIL PURIFIER AND A/E NO. 2 LUBE OIL PURIFIER.
74SOLAS(20) IX/3.1, ISM CODE PART A/6.4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 March 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materias or flammable liquids. Means shall be provided to limit the accumulation of flammable vapours. PSCO observed excessive fuel oil accumulations in the vessel fuel purifier room.
74 SOLAS (2004) II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 March 2024
Resolved
The arrangments for the storage, distribution and uitilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons onboard. PSCO observeed excessive lubricating oil leaks throughout engine room and all 4 generators.
74 SOLAS (2004) II-2/4.2.3.2.3.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 March 2024
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall consist of at lease two generating sets. PSCO observed that the # 4 generator was the only operating generator available. Vessel's crew was able to start the generator after approximately 30 minutes.
74 SOLAS (2020) II-1/ 41.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 March 2024
Resolved
Means shall be provided to control leaks of flammable liquids. F/O accumulation from stbd #1 SSDG; leak observed.
74 SOLAS (20) II-2/4.1.1
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Steam pipes, pressure pipes, wires (insulation)
Issued 16 March 2024
Resolved
Machinery shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces. Missing parts of lagging on main exhaust.
74 SOLAS (20) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 March 2024
Resolved
Provision shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery. Insufficient cleanliness of HFO Purifier Room; Pooled oil under pump with oily rags.
74 SOLAS (20 Cons) II-1/26.7
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 March 2024
Resolved
An alarm system shall indicate visually each separate alarm function. 02 amber light bulbs on alarm light panels were burnt out in engineering space.
74 SOLAS (20 Cons) II-1/51.1.1
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Steam pipes, pressure pipes, wires (insulation)
Issued 16 March 2024
Resolved
Machinery shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces; steam line under deck plate in F/O purifier room found to be leaking steam and not insulated.
74 SOLAS (so Cons) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2024
Resolved
In a ship in which fuel oil is used, the arrangements for storage, distribution, and utilization of the oil fuel shall be as such to ensure the safety of the ship and persons on board. In the oil purified space, PSCO identified a manufactured catch basin attached to the overhead as well as 02 catchbasins under the deck plating containing oil.
74 SOLAS (20) II-2/4.2.2
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 March 2024
Resolved
Means shall be provided to control leaks of flammable liquids. During a Flag inspection, the surveyor identified: "Oil accumulation in the engine room: leaking oil was observed from main engine F.O injection pumps unit No.2, 9,10,11,12"
74 SOLAS (20) II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 March 2024
Resolved
Means shall be provided to control leaks of flammable liquids. During a Flag inspection, the surveyor identified: "Oil accumulation in the engine room: auxillary engines No. 1,2, and 4 were observed with excessive oil leakages (mainly from F.O. injection pumps), and one F.O high pressure pipe on A/E No. 2 was found broken"
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 March 2024
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from storage, settling or day service tank having a capacity of 500L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. The quick closing valves for the main engine and auxilary generator were blocked open in the oil purifier space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 14 March 2024
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. During a Flag inspection, the surveyor identified: "Fire Safety - ventilation: 2 louvers FWD main engine STBD side were stuck open"
74 SOLAS (20) II-2/5.2.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2024
Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. During a Flag inspection, the surveyor identified:"Other (operation of machinery): Ballast pumps No 1 & 2 were reported non operational"
33 CFR 151.2025(a)(1)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 March 2024
Resolved
Means shall be provided to control leaks of flammable liquids. During a Flag inspection, the surveyor identified: "Cleanliness of engine room: overall engine room housekepping and cleanliness was found in poor condition (several spare sparts were seen not secured, several oil leakages were seen around main engine cylinder heads)"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 14 March 2024
Resolved
Means shall be provided to control leaks of flammable liquids. During a Flag inspection, the surveyor identified: "Insulation wetted through (oil): one pipe near A/E no 4, one pipe above boiler cascade tank, and one pipe in purifier room alarm column insulations were found soaked with oil"
74 SOLAS (20) ii-2/4.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2024
Resolved
The machinery, boilers, and other pressure vessels and associated piping system and fittings shall be of a design and construction adequate for the service for which they are intended. During a Flag inspection, the surveyor identified: "Other (machinery): Water leakages were observed from boiler water circulation pumps and from boiler feed water pumps"
74 SOLAS (20) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 March 2024
Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall he as such as to ensure the safety of the ship and persons on board. During a Flag inspection, the surveyor identified: "Oil accumulation in the engine room: oil leakage was identified from G/E LO storage
tank quick closing valve, and from the sight glass of M/E
cylinder LO storage tank."
74 SOLAS (20) II-2/4.3.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2024
Resolved
The machinery, boilers, and other pressure vessels and associated piping system and fittings shall be of a design and construction adequate for the service for which they are intended. During a Flag inspection, the surveyor identified: "Other (machinery): Water leakage was identified from settling tank No. 2 heating valve."
74 SOLAS (2) II-1/26.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that in all respects, that the ship remains fit to proceed to sea without danger the ship or persons on board. During a Flag inspection, the surveyor identified: "Other (machinery): One S.W pipe for fire pump was seen cracked and leaking water into the bilges, and on SW pipe above main air compressors was seen leaking with temporary collecting arrangement is used"
74 SOLAS (20) I/11(a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2024
Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. During a Flag inspection, the surveyor identified: "Ballast Water Treatment System doosing pumps were found leaking in lower engine platform"
33 CFR 151.2025(a)(1)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 March 2024
Resolved
After survey of the ship… has been completed, no change shall be made… to equipment without the sanction of the Administration. During a Flag inspection, the surveyor identified: "Other (fire safety): Hand wheel for isolating valve of main engine turbo charge LO pump No. 2 was found missing"
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 March 2024
Resolved
The company should establish procedures to ensure to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. In meeting these requirements the company should ensure that inspections are held at appropriate intervals, any non-conformity is reported with its possible cause, if known; appropriate corrective action is taken, and records of these activities are maintained. The technical and operational nature of the deficiencies noted above both by the Coast Guard and the Administration, provide evidence of a serious failure of the implementation of the ISM Code. An external audit is required within three months.
74 SOLAS (20) IX/3
ISM Code 10.2
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 March 2024
Resolved
74 SOLAS (20) II-2/14.1.1 "...the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO received a report from the vessel that the water mist system is malfunctioning in the boiler and incinerator area." 60ac
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 November 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire resisting divisions, and protections of opening and penetrations in these divisions. PSCO discovered 03 inoperable self-closing fire doors. 01 was located on the bridge and fails to self-close. 01 was located at a water closet on the upper deck and fails to self-close. 01 was located at a locker room leading to the engine room, fails to self-close, and is bent.
74 SOLAS (04)/ 14.2.1.1
17ac
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
The vessel experienced a grounding while transiting the navigable waters of the United States.
Submit for review a Classification Society report to [email withheld] detailing a completed damage survey, and that the vessels seaworthiness has been restored.
74 SOLAS (14) I/11
60ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulationsto ensure that the ship in all respects shall remain fit to proceed to sea without danger to crew or ship. Steering gear greasing lines were sheared off at the 90 degree brass fitting.SOLAS74 (2004 cons) I/11.a
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 March 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulationsto ensure that the ship in all respects shall remain fit to proceed to sea without danger to crew or ship. An oil leak was observed from the main engine shaft seal. One Drop per min) SOLAS74 (2004 cons) I/11.a
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2021
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Debree was observed obstructing access to quick closing valves.
SOLAS74 (2004 cons) II-2/14.2.1.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Excessive leaking of fuel oil throughout engine room inclduing a major leak in the purifier room.
74 SOLAS (14) I/11(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Excessive water leakage throughout the engine room causing an excessive build up of salt.
74 SOLAS (14) I/11(a)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 March 2021
Resolved
Fire protection systems and fire-fighting systems shall be maintained ready for use. Housing on smoke detector in engine room was disconnected and hanging.
74 SOLAS(04)II-2/14.1.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2021
Resolved
Where necessary, non-conducting mats or gratings shall be provided at the front and rear of the switchboard. Multiple switchboards identified without mats or gratings.