Records from 2016 to 2025. Most recent: inspection, 7 April 2025.
Inspection history · 41
7 April 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8104779
2 April 2025
COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8103975
26 February 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8084191
18 February 2025
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8080559
17 November 2024
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8035326
13 November 2024
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8029949
18 September 2024
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8004878
16 September 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8003300
12 May 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7908639
24 January 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7853587
21 December 2023
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7841546
12 December 2023
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7832630
10 November 2023
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7820408
16 October 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7809350
10 July 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7737969
29 June 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7726250
7 July 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7499700
28 June 2022
PSC B · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7486323
4 November 2021
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7344128
23 August 2021
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7294264
10 July 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7251726
2 May 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7187619
20 April 2021
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7178978
9 April 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7172041
18 September 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7060208
9 March 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6639297
24 December 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6602286
24 December 2018
In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6602308
19 September 2018
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6543168
12 September 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6535540
5 September 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6529807
23 February 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6360349
26 January 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6344209
11 November 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6304878
22 February 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6092435
26 December 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6062381
11 September 2016
Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5997564
21 March 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5837696
8 March 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5829449
3 March 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5826020
9 February 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5812161
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 26 February 2025
Resolved
Ship of 500 GT and upwards shall be provided with at least one International Shore Connection complying with the Fire Safety Code. PSCO observed missing International shore connection. In its place was a 5 hole flange for the ships potable water fill connection.
SOLAS 74 (20)
II-2/10.2.1.7.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2025
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 26 February 2025
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidlines developed by the organization and in a manner having due regard to ensuring the reliability of firefighting systems and appliances. PSCO observed that the vessel had not completed the required checks of its international shore connection.
SOLAS 74 (20)
II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 May 2025
Resolved 28 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 November 2024
Resolved
A fixed fire deection system and fire alarm system shall be provided in accordance with the provisions of this regulation. PSCO observed inoperable fire detection system.
74 SOLAS (20) II-2/7.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 13 November 2024
Resolved 16 November 2024
Resolution: Received class report stating deficiency was rectified.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 November 2024
Resolved
All ships of 300 gross tonnage and upwards engaged on international voyages shall be fitted with an automatic identification system. PSCO observed AIS transmitting incorrect information.
74SOLAS(20) V/19.2.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2024
Resolved 6 December 2024
Resolution: Submitted Class Survey Report showing that the repairs were successful, and the AIS is operational. See documents tab for Class Survey Report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 November 2024
Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material... shall be so arranged that they can be operated from both sides of the bulkhead. PSCO observed broken door handle on door accessing superstructure from aft deck.
ICLL(88) II/12.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2024
Resolved 16 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 November 2024
Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the code so that each floats free. The liferaft painter system shall provide a connection between the ship and the liferaft and not be dragged under by the sinking ship. PSCO observed painter line attached to ship on port and starboard liferafts.
74SOLAS(20) III/13.4.2 LSA 4/4.1.6.1
Action required: 10 - Deficiency Rectified
Due 13 November 2024
Resolved 13 November 2024
Resolution: Crew corrected painter line installation on boht liferafts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 September 2024
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Vessel notified USCG that the #1 generator was inoperable.
74 SOLAS (04) II-I/41.1.1
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 18 September 2024
Resolved 18 September 2024
Resolution: PSCOs attended the vessel to verify class report from vessel. All satifactory.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 12 May 2024
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the code... where davit arms are recovered by power, safety device shall be fitted which will automatically cut off power before the davit arms reach the stops in order to prevent overstressing the falls or the davits, unless the motor is designed to prevent such overstressing. PSCOS observed that the safety device on the port side rescue boat davit failed to cut off power to the motor when tested.
74SOLAS(20)III/34
LSA CODE VI/6.1.2.7
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 May 2024
Resolution: Received class statement and video evidence attesting to the rectification of the lifeboat davit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 December 2023
Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINATINED IN COMPLIANCE WITH STRUCTUAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION. VESSEL REPORTED NUMBER 01 GENERATOR INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2024
Resolved 24 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 November 2023
Resolved
Cargoship shall carry one or more free-fall lifeboats complying with the reguilations of section 4.7 of the code. Vessels free-fall lifeboat was damaged at previous port and was granted to sail with added lifesaving items from the classification society. PSCO observed no free-fall lifeboat onboard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2023
Resolved 12 December 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 10 July 2023
Resolved
OIL FILTERING EQUIPMENT REFERRED TO IN PARAGRAPH 2 OF THIS REGULATION SHALL COMPLY WITH PARAGRAPH 6 OF THIS REGULATION. IN ADDITION, IT SHALL BE PROVIDED WITH ALARM ARRANGEMENTS TO INDICATE WHEN TIS LEVEL CANNOT BE MAINTAINED. PSCO'S OBSERVED DURING OILY WATER SEPERATOR TEST, AFTER EXCEEDING 15 PPM, AUDIBLE ALARM FAILED TO SOUND.
MARPOL 1/14.7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 July 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2023
Resolved
HYDRAULIC POWER-OPERATED STEERING GEAR SHALL BE PROVIDED WITH THE FOLLOWING: A FIXED STORAGE TANK HAVING SUFFICIENT CAPACITY TO RECHARGE AT LEAST ONE POWER ACTUATING SYSTEM INCLUDING THE RESERVOIR... PSCO'S OBSERVED THE FIXED STORGE TANK HAD NO OIL IN IT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 September 2020
Resolved
Each life raft or group of life rafts shall be stowed with a float-free arrangements complying with the requirements of paragraph 4.1.6 of the code so that each floats free... Port and starboard side life rafts were permanently attached to the ship.
74SOLAS(14 Cons.)III/13.4.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 September 2020
Resolved 18 September 2020
Resolution: Vessel crewmembers corrected the deficiency by attaching the painter line to the weak link instead of the metal link attached to the ship.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 24 December 2018
Resolved
1499 - Main turbine propulsion machinery and, where applicable, main internal combustion propulsion machinery and auxiliary machinery shall be provided with automatic shutoff arrangements in the case of failure such as lubricating oil supply failure which could lead rapidly to complete breakdown, serious damage or explosion. While departing Port Everglades, the vessel's oil mist detector malfunctioned causing the main engine to shutdown which lead to loss of propulsion. - 74 SOLAS (2004 Cons)II-1/27.5 . MSC.1/Circ.1345
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 December 2018
Resolution: Class surveyor attended vessel and verified the main engine oil mist detector functioned during an operational test. Survey report attached.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 January 2018
Resolved
1651 - The VHF radio installation, required by regulation 7 . 1 . l, shall also be capable of transmitting and receiving general radio communications. US VHF Marine Band channels can not be selected on both VHF DSC radios due to a malfunction of the selector switch on the the unit. VHF is working on the International channel - 74 SOALS(2014) CH IV/8.2 - 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2018
Resolution: PSC Miami received DNV-GL Survey report(see attached documents). One new VHF DSC was installed in the main bridge port side. A satisfactory test of the newly installed VHF radio was conducted with the Sector Miami command center.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 21 March 2016
Resolved
1599 - All ships of 300 gross tonnage and upwards irrespective of size shall be fitted with a speed and distance measuring device, or other means, to indicate speed and distance through the water. 74 SOLAS (2014) Ch. V/19.2.3.4
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 26 December 2016
Resolution: Repairs completed on 29APR2016 by Mackay Service Technician while vessel was in dry dock.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 10 February 2016
Resolved
0615: Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The rescue boat's outboard motor was found damaged, rendering it inoperable. Rescue boat engine received exemption from Administration. 74 SOLAS (14) CH III/Reg 20.2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 8 March 2016