MAJESTY

MAJESTY is a 2008 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in January 2026, along with 50 deficiencies, 4 operational controls and 1 casualty investigation in 2020.

Records from 2016 to 2026. Most recent: inspection, 14 January 2026.

Built
2008
Last inspected
14 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE6468
986800
Flag
UNITED STATES
Maury page id
psix-986800

Documentation record

Registered dimensions (L × B × D)64.0 ft × 20.0 ft × 5.0 ft
Registered tonnagegross 42 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE BOATS INC · CRISFIELD, MD, UNITED STATES · built 2008
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portATLANTIC BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 27 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Simplified, Gross Ton
34 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

14 January 2026 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8296293
18 November 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8270225
22 May 2025 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8141460
2 December 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8036476
26 August 2024 Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7989214
7 November 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7821451
10 August 2023 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7764566
31 January 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7629215
6 December 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7608654
30 August 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7547181
9 December 2021 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7368956
14 December 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7111314
14 December 2020 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7113591
1 September 2020 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7041614
2 December 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6844399
11 September 2018 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6537919
30 August 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6513676
12 December 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6322001
2 December 2016 Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6052075
22 August 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5979520
22 February 2016 Plan Review "T" Boat
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5819954

Deficiency record · 50

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 November 2025 Resolved
Bilge systems visual indicators did not light up when automatic bilge pump operated, repair audible indicator for 01 high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2026
Resolved 22 December 2025
Resolution: Found loose wire and repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 November 2025 Resolved
Retro reflective tape was found deteriorated on 02 Lifefloats, replace damaged retro, and replace tether line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2026
Resolved 22 December 2025
Resolution: Tether line replaced and damaged retro replaced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 November 2025 Resolved
EPIRB expiration sticker was past due, replace registration sticker once received. Owner has already renewed registration but has not received the sticker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2026
Resolved 22 December 2025
Resolution: Registration sticker was placed on EPIRB.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2025 Resolved
Replace plastic fire hose nozzle with approved nozzle.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2026
Resolved 22 December 2025
Resolution: Brass nozzle ordered and placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 December 2024 Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas to be protected by the interconnected detection. There is no interconnected detection and alarm system. Limited to within a limited coastwise voyages.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 December 2024
Resolution: Interconnected system provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 December 2024 Resolved
Stowed in a way that neither the survival craft nor its stowage arrangements will interfere with embarkation and operation of any other survival craft. The painter lines for the life floats are too short to be launched without interference.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 12 December 2024
Resolution: Satisfactory arrangement provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 2 December 2024 Resolved
A penetration in a watertight bulkhead must be made watertight. Shift cable penetration through multiple bulkheads are not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 12 December 2024
Resolution: Penetrations sealed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2024 Resolved
At each inspection for certification, the vessel owner shall be prepared to have the vessel ready for inspections of the hull structure. Center line stern frame fastener has failed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2024
Resolved 12 December 2024
Resolution: Frame secured with metallic straps, screws and caulk. Deficiency issued for permanent repair at next drydock.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 December 2024 Resolved
At each inspection for certification, the vessel owner shall be prepared to have the vessel ready for inspections of the hull structure. Center line stern frame temporarily secured with metallic strips and screws. 1. Monitor frame for movement. 2. Reapir to original at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 January 2026
Resolution: Verified proper and permanent repairs made and satisfied.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2020 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Repair Starboard Propulsion Transmission hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2021
Resolved 23 December 2020
Resolution: Hydraulic hose replaced, system tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2020 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required. Provide fire extinguishers as per COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2021
Resolved 23 December 2020
Resolution: Fire extinguisher replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 December 2020 Resolved
The float-free link required by §180.130(a)(1) must be Certified to meet §160.073 in subchapter Q. Provide float-free link ID tag.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2021
Resolved 23 December 2020
Resolution: Float free link replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 December 2020 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Provide portable lights for operating station and at access to propulsion machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2021
Resolved 23 December 2020
Resolution: Portable battery operated lights provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 December 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2021
Resolved 23 December 2020
Resolution: All DAPI requirements met.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 September 2020 Resolved
All vessels shall be drydocked and subject to inspection. The items listed a) through c) shall be be completed before the vessel is placed back in the water. All items shall be inspected by a marine inspector before receiving credit for drydock. a) Damage to FRP on various areas of the hull below and near water line exposing chop strand. Provide a repair proposal. b) Various small areas of coating failure noted throughout the hull. Re-coat all exposed FRP. c) Replace water lubricated bearings on port and starboard shaft struts. d) Replace rotted longitudinal frames under port and starboard engines as well as aft transverse frame. e) Wood rot in lazarette in port overhead deck, provide repair proposal. f) Non-metallic fuel lines must be approved type SAE-J-1942, less than 30 inches long with metallic fittings for bulkhead penetrations. g) Properly seal hull penetrations on port and starboard exhaust pipe discharge. h) Properly seal forward bulkhead exhaust penetration in lazarette. i) Properly seal penetrations at located top of forward lazarette bulkhead. j) Properly seal hydraulic line bulkhead penetrations in forward compartment and forepeak. k) Properly seal forward bulkhead fixed bilge pipe penetration. l) Fixed bilge system piping in lazarette and forward compartment missing strainers. m) Securely attach engine room ladder. n) Repair broken hydraulic support brackets in forepeak. o) Replace heat sensor and wiring on starboard engine. p) Starboard engine raw water cooling valve difficult to fully close. q) Properly secure starboard engine raw water strainer. r) Install double hose clamps on electric submersible bilge pump overboard discharge in engine room and on MSD tank flexible hoses. s) Properly secure port and starboard exhaust supports.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2020
Resolved 12 November 2020
Resolution: Worklist items a a through q complete, remaining items converted to deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 January 2020 Resolved
EACH DISPOSABLE HYDROSTATIC RELEASE UNIT MUST BE MNARKED WITH AN EXPIRATION DATE OF TWO YEARS AFTER THE DATE ON WHICH THE UNIT IS INSTALLED. HYDROSTATIC RELEASE UNIT IS EXPIRED. HAVE THE HYDROSTATIC RELEASE UNIT REPLACED. ***LIMITED ROUTE, NOT TO EXCEED 3NM ***
Action required: 705 - Other - as specified
Due 5 February 2020
Resolved 7 January 2020
Resolution: Captain sent pictures if new EPIRB with newly inspected hydrostatic release. Sent verification from NOAA that EPIRD has been registered to M/V MAJESTY.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020 Resolved
WHERE FLEXIBLE NONMETALLIC HOSE IS PERMITTED FOR HTE USE IN PIPING SYSTEMS BY THIS SECTION, IT MUST MEET SAE-J-1942. THE FUEL HOSE FITTED ON THE AFT FUEL TANK DID NOT MEET THESE STANDARDS. REPLACE HOSE WITH APPROVED SAE-J-1942 HOSE WITH APPROVED BULKHEAD PENETRATIONS SAE-J-1527. TO BE RECTIFIED BY COMPLETION OF THE NEXT DRYDOCK IN AUGUST 2020.
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 14 December 2020
Resolution: Verified proper installation to meet requirements.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 2 December 2019 Resolved
SHUTOFF VALVES INSTALLED SO AS TO CLOSE AGAINST THE FUEL FLOW. THE SHUTOFF VALVE AT THE TANK MUST BE MANUALLY OPERABLE FROM OUTSIDE THE COMPARTMENT IN WHICH THE VALVE IS LOCATED. BOLT ON THE SHUTOFF VALVE IS STRIPPED. REPLACE WITH A NEW WORKING HANDLE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 6 January 2020
Resolution: Went on board 6JAN20 and tested shutoff valve to the satisfaction of CG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 December 2019 Resolved
EXHAUST GAS MUST NOT LEAK FROM THE PIPING OR ANY CONNECTIONS. BOTH MAIN ENGINES HAVE EXHAUST LEAKS, ROUTE CRANKCASE EXHAUST PROPERLY.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 6 January 2020
Resolution: 6JAN20 went on board to confirm crankcase exhaust leak has been fixed (rerouted to vent to atmosphere). Rectified to the satisfaction of CG.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 December 2019 Resolved
A VESSEL MUST COMPLY WITH THE APPLICABLE REQUIREMENTS FOR ANY RADIO INSTALLATIONS, INCLUDING THE REQUIREMENTS FOR A STATION LICENSE AND INSTALLATION CERTIFICATES. -DOES NOT HAVE THE FCC SAFETY CERTIFICATE ON BOARD. -VHF-DSC RADIO DOES NOT HAVE THE MMSI AND GPS INPUTED -SSB IS NOT DSC CAPABLE
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 6 January 2020
Resolution: Rectified to the satisfaction of CG
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 December 2019 Resolved
THE NUMBER OF PENETRATIONS IN A WATERTIGHT BULKHEAD MUST BE AS HIGH AND AS FAR INBOARD IN THE BULKHEAD AS PRACTICABLE AND MADE WATERTIGHT. VESSEL HAS PENETRATIONS NOT PROPERLY SEALED. USE PROPER SEALANT IN SEAL PENETRATIONS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 6 January 2020
Resolution: Rectified to the satisfaction of CG
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 December 2019 Resolved
CHARTS OF LARGE ENOUGH SCALE TO MAKE SAFE NAVIGATION POSSIBLE. VESSEL DID NOT HAVE A PAPER CHART ONBOARD, GET A CHART FOR PROPER AOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 6 January 2020
Resolution: Charts for the proper AOR were onboard.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 December 2019 Resolved
ON A VESSEL CARRYING MORE THAN 49 PASSENGERS, THE PUMP OUTLET MUST BE FITTED WITH A PRESSURE GUAGE. PRESSURE GUAGE DID NOT WORK. REPLACE GUAGE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2020
Resolved 6 January 2020
Resolution: Pressure guage was added and tested to the satisfaction of the CG.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2018 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Mark stowage compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 12 October 2018
Resolution: Verified proper stowage with required markings.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 September 2018 Resolved
A vessel on an oceans route must carry six hand orange smoke distress signals. Replace the 03 missing signals.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2018
Resolution: Approved distress flares purchased to meet minimum requirement.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 September 2018 Resolved
A visual and audible alarm must be provided at the operating station. Repair the stern bilge visual indicator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 12 October 2018
Resolution: Verified visual and audible alarm at the operating station after activation of stern bilge high water level alarm.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 September 2018 Resolved
The items contained in first-aid kit shall be as listed in table 160.041-4(b). Several items were missing.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 12 October 2018
Resolution: Verified required equipment was replaced.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 13 September 2018 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of the vessel. Add the use of the rescue ladder to the list
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 12 October 2018
Resolution: Verified emergency instructions were updated IAW shipboard procedures.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 September 2018 Resolved
Pre-engineered fixed gas fire extinguishing systems must automatically shut down engines that draw intake air from within the protected space. The SSDG did not shut down upon activation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 12 October 2018
Resolution: Verified automatic shutdown of SSDG upon activation of pre-engineered fixed gas extinguishing system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
Display and distribution of a community service EAP hot- line telephone number for crewmember assistance.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 12 October 2018
Resolution: Verified EAP number available for crewmember assistance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2018 Resolved
As an employer, you are responsible for meeting all applicable requirements and procedures for DAPI. Prove with written compliance.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 31 October 2018
Resolution: DAPI plan was updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 September 2018 Resolved
Repair hydraulic leak from steering gear ram.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 12 October 2018
Resolution: Verified repairs were made to hydraulic steering ram.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 September 2018 Resolved
Submit repair proposal and repair lazarette PORT ovhd deck wood rot prior to next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: To be repaired at next drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 September 2018 Resolved
Submit repair proposal and repair STBD engine bed wood rot prior to next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: To be repaired at next drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 September 2018 Resolved
Submit repair proposal and repair fore peak PORT ovhd wood rot prior to next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: To be repaired at next drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 September 2018 Resolved
Submit repair proposal and repair lazarette STBD exhaust penetration wood rot prior to next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: To be repaired at next drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 August 2018 Resolved
Submit repair proposal and repair STBD engine bed wood rot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Issued CG835 deficiency during COI, see activity 6537919 for details.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 August 2018 Resolved
Submit proposal and repair fore peak PORT ovhd wood rot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 13 September 2018
Resolution: Issued CG835 deficiency during COI, see activity 6537919 for details.
Engineering › Fuel Oil Service System › Hose
Issued 12 December 2017 Resolved
Repair port main engine fuel return line leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Resolution: Fuel line was recut and reclamped. Cleared.
Engineering › Lubricating Oil Service System › Gauge
Issued 12 December 2017 Resolved
Repair port side engine oil pressure gauge.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Resolution: Cleared.
Engineering › Bilge Water Management System › Not Operational
Issued 12 December 2017 Resolved
Repair tank space bilge light and audible alarm at operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Resolution: All SAT. Cleared.
Engineering › Bilge Water Management System › Interface Detector
Issued 12 December 2017 Resolved
Repair engine room bilge alarm light at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 29 December 2017
Resolution: Cleared
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 12 December 2017 Resolved
Repair starboard engine turbo oil return leak.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 15 December 2017
Resolution: Cleared.
Lifesaving › Lifefloat › Retroreflective Material
Issued 12 December 2017 Resolved
Add proper amount of Type II retro-reflective take on all lifefloats.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2017
Resolution: Cleared.
Engineering › Fuel Oil Service System › Piping
Issued 14 December 2016 Resolved
Prove proper operation of starboard engine to attending MI's. 46 CFR 182.200
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2016
Resolved 16 December 2016
Resolution: Conducted satisfactory sea trials for 30 minutes at various speeds.
Lifesaving › Lifefloat › Float Free
Issued 2 December 2016 Resolved
Reroute shrouds to mast to ensure all 03 life floats float free.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 16 December 2016
Resolution: Vessel owner rerouted the shrouds as discussed to ensure a float free arrangement.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 December 2016 Resolved
Replace exhaust cooling water pipe on port engine (02) temp. patches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 13 January 2017
Resolution: A new in kind pipe was installed.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 2 December 2016 Resolved
Renew worn engine shutdown solenoid components on both engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 13 January 2017
Resolution: New fittings were installed as required.
Engineering › Fuel Oil Service System › Piping
Issued 30 August 2016 Resolved
Remove all flexible nonmetallic fuel hose that is not USCG approved from MDE's and replace as original.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 22 September 2016
Resolution: Replaced flexible nonmetallic fuel hose with copper pipe from the tank to the BLKD and CG approved nonmetallic fuel hose from the RACOR filters to the M/E.
Construction/Loadline › Structures › Ventilators
Issued 4 March 2016 Resolved
Vessel has made unauthorized alterations to the deck, added gooseneck ventilation valves to the forepeak space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2016
Resolved 9 March 2016
Resolution: Repair proposal approved. Vents installed and inspected by attending MI.

Casualty record · 1

14 December 2020Routine · role: Involved in a Marine Casualty · activity 7113591
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.