Records from 2016 to 2021. Most recent: inspection, 11 May 2021.
Inspection history · 10
11 May 2021
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7194747
28 April 2021
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7181216
16 November 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7096290
15 October 2019
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6830756
14 October 2019
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6830753
1 October 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6817740
16 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6288256
13 October 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6282127
10 October 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6285068
14 July 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5934863
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 April 2021
Resolved
Ventilation ducts shall be of non-combustible material. Approved duct material removed in GMDSS battery room and replaced with unapproved arrangement to support installation of unapproved cooling system - 74 SOLAS (04) II-2/9.7.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 11 May 2021
Resolution: Class survey received attesting to the satisfactory repair of affected system. Deficiency cleared in activity #7194747
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 April 2021
Resolved
After any survey of the ship, no change shall be made in the structural arrangements covered by the survey. In vessel's dry stores, temporary repair made using tape for corroded area in ceiling - 74 SOLAS (14) I/11(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 11 May 2021
Resolution: Class survey received attesting to the satisfactory repair of affected system. Deficiency cleared in activity #7194747
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 13 October 2017
Resolved
PSCO noted a jump cable from forward Emergency light on Port / Starboard deck cable runs to junction box for embarkation lights.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 October 2017
Resolution: PSC NEW ORLEANS received class report from DNV - GL satisfying requirement.
Electrical › Lighting (service) › Outlet Box
Issued 13 October 2017
Resolved
PSCO noted electrical box plug cover missing between cargo holds and forward on deck and starboard side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 October 2017
Resolution: PSC NEW ORLEANS received report satisfying requirement.
Electrical › Lighting (service) › Neutral Ground
Issued 13 October 2017
Resolved
PSCO noted spot lights around periphery of vessel not grounded.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 October 2017
Resolution: PSC NEW ORLEANS received report from DNV-GL satisfying requirement.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 13 October 2017
Resolved
Vent covers on exterior of vessel unable to be properly sealed due to bolts being removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 October 2017
Resolution: PSC NEW ORLEANS received report from DNV-GL satisfying requirement.