The 1 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for EPIC ST. LUCIA, retrieved 18 September 2026. mauryrecords.com/v/psix-987149.html
Documentation record
Tonnage as PSIX records it5035 - Dead Weight, Ton 4253 - Simplified, Gross Ton 4253 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 1
13 August 2015COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5208193
Electrical › Electric Supply System (service) › Cable
Issued 13 August 2015Resolved
Electrical installations shall be such that the sagety of the crew and ship from hazards be ensured.
1) The suez canal search light electrical wire was cut.
2) The light fixture within the forward motor room had a melted cover and broken bulbs.
74 SOLAS (2014 CONS) II-1/40.1.3 ; 10c
Condition: Improper Installation
Due 13 August 2015
Resolved 13 August 2015
Resolution: Vessel electrician was able to to properly remove the cut wire and replace the melted light fixture while Coast Guard Sector Guam was on board.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 13 August 2015Resolved
Fire fighting systems and appliances shall be kept readily available for immediate use. Testing equipment was left over a hyper mist nozzle.
74 SOLAS (2014 CONS) II-2 / 14.2.1.2
10c
Condition: Improper Installation
Due 13 August 2015
Resolved 13 August 2015
Resolution: The vessel''s Chief Engineer removed the installed testing equipment.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 13 August 2015Resolved
an inert gas system should have pressure controls and monitoring arrangements appropriate to the cargo containment system. The PSA NGG pressure controls and monitorying arrangemtns between the engine room and the cargo control room were not operating properly.
74 SOLAS (2014 CONS) II-2/4.5.6
IGC CODE (1993) 9.5.2
Action required: 705 - Other - as specified
Resolved 13 August 2015
Resolution: The vessel''s Chief Engineer adjusted a pressure control module in the cargo control room control panel.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.