Records from 2016 to 2019. Most recent: inspection, 3 September 2019.
Inspection history · 5
3 September 2019
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6803085
21 August 2019
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6769681
28 March 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5842108
14 March 2016
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5833115
15 February 2016
Ballast Water Examination · ISPS II Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination · COC-TVE Renew · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5816262
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 August 2019
Resolved
PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR SERVICE FOR WHICH THEY ARE INTENDED. OBSERVED DIESEL OIL DISCHARGED IN THE PURIFIER ROOM DUE TO FAILED GASKET. SOLAS 2004 CH II-I, REG 26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Ships crew replace the leaking gasket on the purifier.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019
Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. OBSERVED THAT INCINERATOR WAS WIRED TO THE POWER SOURCE BY BY AN UNAPROVED MODIFICATION. SOLAS 2004 CH II-I, REG 45.1.3
Action required: 10 - Deficiency Rectified
Resolved 21 August 2019
Resolution: CREW REMOVED THE UNAPROVED WIRING MODIFICATION.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2019
Resolved
ELECTRICAL INSTALLATIONS SHALL BE AS SUCH THAT ELECTRICAL SERVICES ESSENTIAL FOR SAFETY WILL BE ENSURED UNDER VARIOUS CONDITIONS. OBSERVED THAT GROUNDING CABLES WERE MISSING FROM PORT AND STARBOARD MANIFOLD EMERGENCY STOPS. SOLAS 2004 Ch II-1 Reg 40.1.2
Action required: 10 - Deficiency Rectified
Resolved 21 August 2019
Resolution: CREW REPLACED GROUNDING CABLES
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 August 2019
Resolved
ELECTRICAL SERVICES ESSENTIAL FOR SAFETY WILL BE ENSURED UNDER VARIOUS EMERGENCY CONDITIONS. EMERGENCY LIGHTING UNDER NUMBER 3 GENERATOR NOT WORKING. SOLAS 2004 CH II-I, REG 40.1.2
Action required: 10 - Deficiency Rectified
Resolved 21 August 2019
Resolution: CREW REPAIRED THE LIGHT
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 August 2019
Resolved
EMERGENCY GENERATOR MANUAL STARTING IS PERMISSIBLE WHERE IT CAN BE DEMONSTRATED EFFECTIVE. OBERVED A LEAK COMING FROM HYDRAULIC STARTING SYSTEM DUE TO FAILED GASKET. SOLAS 2004 CH II-I, 45.4.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 3 September 2019
Resolution: Ships crew replaced the leaking gasket on the emergency generator hydraulic start tank.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 21 August 2019
Resolved
PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE INTENDED SERVICE. OBSERVED STEAM PIPES LACKING INSULATION. SOLAS 2014 Ch II-1 Reg 26.1
Action required: 10 - Deficiency Rectified
Resolved 21 August 2019
Resolution: INSULATION REPLACED
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 21 August 2019
Resolved
PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE INTENDED SERVICE. OBSERVED A LEAKING STEAM VALVE ON THE BOILERS. SOLAS 2014 Ch II-1 Reg 26.1
Action required: 10 - Deficiency Rectified
Resolved 21 August 2019
Resolution: CREW REPAIRED VALVE.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 February 2016
Resolved
01-0715-THE FIRE DETECTION AND FIRE ALARM SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. PSCO OBSERVED IN THE ENGINE ROOM WORKSHOP, 3 SMOKE DETECTORS WITH PLASTIC COVERINGS, PREVENTING PROPER OPERATIONS OF THE DETECTORS. - 74SOLAS(14) II-2/2.1.1.2 - 50B PLEASE SEE FORM B FOR CORRECTIVE ACTIONS NEEDED TO BE TAKEN.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 27 March 2016
Resolution: Received report of training completed