Exposed rotted steel electrical conduit through out entire cargo deck leading into deck house, forward peak, deck work shop. Existing conduit has painted tape covering wastage. Deck light fixtures have all open wires exposing the internal connections.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 20 October 2008
No resolution recorded
All PV's on center cargo tanks severely pitted and leaking by, the crew made temp repairs on the bullets using epoxy, all the vacuum breakers flame screens are corroded and falling off the valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Stability › Watertight Integrity › Weathertight Enclosure
Issued 20 October 2008
Resolved
Forward peak water tight hatch in Bosun hole blocked by an air compressor discharge line that was installed right over the hatch inner dog. Hatch un-able to secure or open with out removal of the steel air line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 October 2008
Resolution: Ships crew removed the air line and proved operation of the water tight fitting.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 20 October 2008
Resolved
Port bow lifeline broken and wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 October 2008
Electrical › Electrical Distribution System (emergency) › Grounding Conductor
Issued 20 October 2008
No resolution recorded
Bonding wire disconnected on forward cargo deck piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Deck/Cargo › Mooring/Anchoring › Winch
Issued 20 October 2008
Resolved
Fractured hydraulic line on deck crane, crane leaking hydraulic fluid on cargo deck. Severe wastage of hydraulic fittings on crane.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 October 2008
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 20 October 2008
Resolved
Toilet in hospital space in-operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 October 2008
Operations/Management › Cargo Transfer/Lightering › Pre-transfer Inspection
Issued 20 October 2008
No resolution recorded
Gas free pump room via Marine Chemist for Inspector's access.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 20 October 2008
No resolution recorded
IG deck seal appears wasted and needs to be gauged for thickness.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 20 October 2008
No resolution recorded
Request an ISM audit due to the lack of several non-conformities found during the Port State exam concerning maintenance of lifesaving & cargo safety.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Lifesaving › Launching Appliances › Davit
Issued 15 October 2008
No resolution recorded
Both Port and Starboard life boat davits are severely corroded around the sheave support area's. While lowering the STBD life boat multiple sheaves were seized do to the rust build up, the crew removed the flaking rust which revealed thin severely steel which supports the lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified