← All vessels
CEDAR
Freight Ship · Bulk Carrier class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named CEDAR
CEDAR is a 2008 freight ship. The Coast Guard has recorded 16 inspections since 2008, most recently in February 2023, along with 10 deficiencies and 2 operational controls.
Records from 2008 to 2023. Most recent: inspection, 15 February 2023.
- Built
- 2008
- Last inspected
- 15 February 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9403035 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3710
987911
Flag
SINGAPORE
—
Maury page id
psix-987911
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (2008–2023)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it32379 - Convention (Subpart B), Gross Ton
19353 - Convention (Subpart B), Net Ton
58802 - Dead Weight, Metric Ton
67814 - Displacement, Metric Ton
19353 - Convention (Subpart B), Net Ton
58802 - Dead Weight, Metric Ton
67814 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
15 February 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7637127
8 September 2021
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7302748
5 September 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7304489
10 February 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6903080
16 January 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6890971
22 December 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6877891
12 June 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6711555
11 June 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6710858
10 June 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6710053
14 July 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6478577
10 June 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6440265
9 June 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6438707
14 March 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6103682
23 September 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6007658
12 March 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5831444
6 November 2008
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3346012
Deficiency record · 10
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 September 2021
Resolved
Bulk carriers shall comply with the maintenancerequirements provided in regulation II-1/3-1 and the standards for owner's inspection and maintenace of bulk carrier hatch covers, adopted by the Organization by resolution MSC.169(79) PSCO observed that the maintenance tasks listed in resolution MSC.169(79)are not being carried out on a monthly basis.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 September 2021
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. PSCO observed clamping devicesto cargo hold hatch covers were seized due to lack of maintenace and weathertight fittings to all crane towers were inoperable and/or deteriorated.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 8 September 2021
Resolved
When transporting a solid bulk cargo which is liable to emit a toxic or flammable gas, or cause oxygen depletion in the cargo space, an appropriate instrument for measuring the concentration of gas or oxygen in the air shall be provided with details instructions for its use. PSCO observed that bump testing was not being carried out in accordance with manufacturers recommendations.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 December 2019
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed the number one, two, and five cylinders fuel injector pump on the main engine was leaking fuel oil.
Solas 74 (a) 2014(cons) II-2/ 4.1
60ac
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 December 2019
Resolved
The Oil Record Book Part 1 shall be completed on each occasion, on tank to tank basis if appropriate, whenever the following machinery space operations take place in the ship: Discharge overboard or disposal otherwise of bilge water which has accumulated in the machinery spaces. PSCO observed that the duration of time the oil filtering equipment was used documented in the Oil Record Book Part 1 was not accurate and IAW OCM history. Provide clarification from Administration within 30 days attesting to the duration of time and accurate documentation within the Oil Record Book. Marpol Annex I/ 17.2.4
B
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 22 December 2019
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stress to which is may be subjected. PSCO observed severe steam leak coming from the cascade tank steam line.
Solas 74 (a) 2004 (cons) II-1/ 33
10c
Engineering › Fuel Oil Service System › Piping
Issued 12 March 2016
Resolved
74 SOLAS (2009 cond) II-2/REG 4.1.1 - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. Multiple fuel leaks on the #3 generator creating a probability of ignition. 17 AC
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 12 March 2016
Resolved
74 SOLAS (2009 cond) II-2/REG 4.1.1 - Every steam pipe and every fitting connected thereto through wich steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. Multiple leaks in steam piping throughout engine room creating a safety hazard to the crew. 17ac
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 12 March 2016
Resolved
74 SOLAS (2009 cond) IX/REG 3.1 ISM 10.2.3 - The company and the ship shall comply with the requirements of the ISM code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations (see narrative)
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 6 November 2008
Resolved
Aft air-dam entry door to steering gear space is designated on fire control plan as an "A" class self closing door. Door on space is marked as "C" class.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National