CEDAR is a 2008 freight ship. The Coast Guard has recorded 15 inspections since 2016, most recently in February 2023, along with 9 deficiencies and 2 operational controls.
Records from 2016 to 2023. Most recent: inspection, 15 February 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it32379 - Convention (Subpart B), Gross Ton 19353 - Convention (Subpart B), Net Ton 58802 - Dead Weight, Metric Ton 67814 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
15 February 2023Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7637127
8 September 2021PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7302748
5 September 2021Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7304489
10 February 2020PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6903080
16 January 2020Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6890971
22 December 2019PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6877891
12 June 2019PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6711555
11 June 2019Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6710858
10 June 2019Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6710053
14 July 2018Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6478577
10 June 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6440265
9 June 2018PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6438707
14 March 2017Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6103682
23 September 2016Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6007658
12 March 2016PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5831444
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 September 2021Resolved
Bulk carriers shall comply with the maintenancerequirements provided in regulation II-1/3-1 and the standards for owner's inspection and maintenace of bulk carrier hatch covers, adopted by the Organization by resolution MSC.169(79) PSCO observed that the maintenance tasks listed in resolution MSC.169(79)are not being carried out on a monthly basis.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2021
Resolved 11 September 2021
Resolution: Class verified vessel company developed a program under MSC.169(79) and certified it.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 September 2021Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. PSCO observed clamping devicesto cargo hold hatch covers were seized due to lack of maintenace and weathertight fittings to all crane towers were inoperable and/or deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2021
Resolved 11 September 2021
Resolution: Class verified repirs/maintenance were carried out in a satisfactory manner.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 8 September 2021Resolved
When transporting a solid bulk cargo which is liable to emit a toxic or flammable gas, or cause oxygen depletion in the cargo space, an appropriate instrument for measuring the concentration of gas or oxygen in the air shall be provided with details instructions for its use. PSCO observed that bump testing was not being carried out in accordance with manufacturers recommendations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2021
Resolved 11 October 2021
Resolution: Reviewed class report lsiting new calibration gas onboard.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 December 2019Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed the number one, two, and five cylinders fuel injector pump on the main engine was leaking fuel oil.
Solas 74 (a) 2014(cons) II-2/ 4.1
60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 December 2019
Resolution: 31DEC19: Received, reviewed, and accepted LR Class Report attesting to rectification of leaking fuel ijector pumps on No. 1, 2, and 5 cylinders on main engine.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 December 2019Resolved
The Oil Record Book Part 1 shall be completed on each occasion, on tank to tank basis if appropriate, whenever the following machinery space operations take place in the ship: Discharge overboard or disposal otherwise of bilge water which has accumulated in the machinery spaces. PSCO observed that the duration of time the oil filtering equipment was used documented in the Oil Record Book Part 1 was not accurate and IAW OCM history. Provide clarification from Administration within 30 days attesting to the duration of time and accurate documentation within the Oil Record Book. Marpol Annex I/ 17.2.4
B
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2020
Resolved 16 January 2020
Resolution: PSC NOLA received report of crew conducted traning for entry of oil record book
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 22 December 2019Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stress to which is may be subjected. PSCO observed severe steam leak coming from the cascade tank steam line.
Solas 74 (a) 2004 (cons) II-1/ 33
10c
Action required: 10 - Deficiency Rectified
Resolved 22 December 2019
Resolution: corrected on the spot
Engineering › Fuel Oil Service System › Piping
Issued 12 March 2016Resolved
74 SOLAS (2009 cond) II-2/REG 4.1.1 - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. Multiple fuel leaks on the #3 generator creating a probability of ignition. 17 AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2016
Resolution: Received Class Report verifying deficiencies have been corrected.
74 SOLAS (2009 cond) II-2/REG 4.1.1 - Every steam pipe and every fitting connected thereto through wich steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. Multiple leaks in steam piping throughout engine room creating a safety hazard to the crew. 17ac
Action required: 15 - Rectify deficiencies by next port
Resolved 12 March 2016
Resolution: Received Class Report verifying deficiencies have been corrected.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 12 March 2016Resolved
74 SOLAS (2009 cond) IX/REG 3.1 ISM 10.2.3 - The company and the ship shall comply with the requirements of the ISM code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations (see narrative)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 September 2016
Resolution: Management of this vessel has completed investigation process on this deficiency and reported to ship's RO-Lloyd's Register. Corrective action is accepted by RO at completion of the review process and new operating procedures have been implemented.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.