MAURY USCG vessel records
← All vessels

HELIX PRODUCER I

HELIX PRODUCER I is a 1986 offshore supply vessel. The Coast Guard has recorded 31 inspections since 2016, most recently in April 2025, along with 9 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 10 April 2025.

Built
1986
Last inspected
10 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 April 2025
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8420115
988017
Flag
BAHAMAS, THE
Maury page id
psix-988017

Documentation record

Tonnage as PSIX records it17357 - Convention (Subpart B), Gross Ton
14316 - Dead Weight, Metric Ton
24456 - Displacement, Metric Ton
5207 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 31

10 April 2025 ISPS Exam · COC-MODU Renew · Ballast Water Examination
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8111239
17 July 2024 COC-MODU Renew · ISPS Exam
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7964610
3 June 2024 In-Service Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7926329
31 May 2024 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7900248
29 February 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7969664
1 February 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7929307
19 May 2023 COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7663297
31 August 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7541519
11 August 2022 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7530964
4 August 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7524795
21 April 2022 COC-MODU Renew · Deficiency Check
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 7434720
30 April 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7188381
12 April 2021 COC-MODU Annual · ISPS Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7195348
22 April 2020 COC-MODU Renew · ISPS Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6943516
6 August 2019 COC-MODU Annual · ISPS III Exam
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6775796
23 April 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6674914
17 April 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6665204
9 March 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6644338
6 February 2019 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611264
16 January 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611293
26 December 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6607126
11 June 2018 In-Service Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6452189
9 June 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6579457
1 May 2018 COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6457844
23 January 2018 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6343743
9 June 2017 COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6191940
12 October 2016 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6071735
20 September 2016 ISPS II Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5999665
19 September 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6005819
18 July 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5982201
13 May 2016 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5879474

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2022 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect in compartments assigned principally to accumulator batteries, in paint lockers, acetylene stores, or similar spaces unless such equipment is appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. Inspectors observed lighting installations in battery rooms 26 B and C that were not appropriately rated for the vapors likely to be encountered.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 9 May 2022
Resolution: New lights that meet the vessel's DBA with the CG were sourced and installed in both battery rooms as shown by photographic evidence provided. Appleton Type FLe lights with IEC marking Ex demb IIC T4 Gb and -40°C = Ta = +55°C ambient temperature rating.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 April 2022 Resolved
Persons responsible for actual operations, including owners, operators, contractors, and subcontractors, shall ensure that those operations subject to their control are conducted in compliance with workplace safety and health regulations of this part and, in addition, free from recognized hazards. Inspectors observed a multitude of equipment on the 03 Deck Production Storage Room and Engine Department Storage Rooms not properly secured for expected vessel movement. Examples of the observed hazards included wheeled tool chests free to roll, cabinets not secured from tipping, and assorted industrial valves and equipment not secured on shelving.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 29 April 2022
Resolution: Received detailed documentation, including photos, from the Master showing satisfactory completion. Pump Room wheeled tool chest secured, one ECR cabinet secured/one removed and Deck 3 equipment secured. Addt'l shelf stowage netting/devices procured.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 11 June 2018 Resolved
Vessel suffered a drift off due to a DP failure. Operator provided DP FMEA's. After review by CG ENG it was found that FMEA's did not address root cause. Vessel required to operate in open bus configuration until further notice.
Action required: 705 - Other - as specified
Due 22 August 2018
Resolved 10 April 2019
Resolution: Upon completion of FMEA and MCS review of results, deficiency has been rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 May 2018 Resolved
Davit arm autmoatic stop limit switch was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 22 May 2018
Resolution: Recieved Lloyds report of correction of deficiencies.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 1 May 2018 Resolved
Vessel did not have proper annex VI / NOX tech files or parts change out.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2018
Resolved 22 May 2018
Resolution: Recieved report from Lloyds stating def's have been cleared.
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 5 October 2016 Resolved
DG #3 & #4 were unable to be tested upon complete of yard work. Must be tested prior to connecting to DP system
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 October 2016
Resolution: Received Class approval for completion of work on said equipment and successful testing.
Engineering › Thrusters › Seal
Issued 5 October 2016 Resolved
seals were replaced during 2016 D/D. Proof testing must be completed prior to production
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 October 2016
Resolution: Received Class approval for completion of work on said equipment and successful testing.
Lifesaving › Launching Appliances › Winch Brake
Issued 13 May 2016 Resolved
The brakes for lifeboats #1 and #4 stuck when operated in the presence of the MI. Provide prrof of davit brakes operating correctly. [46 CFR 109.301(a)] 50c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2016
Resolved 31 May 2016
Resolution: Received e-mail w/ attached service report from Port Engineer [name withheld] Guesno approved repair work a cleared deficiency.
Lifesaving › Inflatable Liferafts › Float Free
Issued 13 May 2016 Resolved
The liferafts on the aft mooring decks are constrained in their ability to float free by the overhead of the deck above. Shall rectify at upcoming drydock. [46 CFR 108.525 (a)(2)] 17c-from drydock]
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2016
Resolved 24 July 2016
Resolution: Received email from Port Engineer with reason why aft life rafts may be in an obstructed position. SOLAS Chap. III reg. 31.1.4 allows arrangement.

Ownership record