Records from 2009 to 2025. Most recent: inspection, 10 April 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
10 April 2025
ISPS Exam · COC-MODU Renew · Ballast Water Examination
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8111239
17 July 2024
COC-MODU Renew · ISPS Exam
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7964610
3 June 2024
In-Service Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7926329
31 May 2024
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7900248
29 February 2024
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7969664
1 February 2024
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7929307
19 May 2023
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7663297
31 August 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7541519
11 August 2022
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7530964
4 August 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7524795
21 April 2022
COC-MODU Renew · Deficiency Check
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 7434720
30 April 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7188381
12 April 2021
COC-MODU Annual · ISPS Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7195348
22 April 2020
COC-MODU Renew · ISPS Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6943516
6 August 2019
COC-MODU Annual · ISPS III Exam
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6775796
23 April 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6674914
17 April 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6665204
9 March 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6644338
6 February 2019
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611264
16 January 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611293
26 December 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6607126
11 June 2018
In-Service Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6452189
9 June 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6579457
1 May 2018
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6457844
23 January 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6343743
9 June 2017
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6191940
12 October 2016
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6071735
20 September 2016
ISPS II Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5999665
19 September 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6005819
18 July 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5982201
13 May 2016
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5879474
14 May 2014
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4858840
24 May 2012
Administrative Inspection · COC-MODU Renew · ISPS III Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4300210
24 August 2011
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4156161
18 September 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3852349
22 February 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3683935
20 February 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3683326
17 February 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3681295
10 February 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3678707
22 April 2009
PII Safety Exam · Deficiency Check · ISPS II Exam · ILO-147 Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3458165
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2022
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect in compartments assigned principally to accumulator batteries, in paint lockers, acetylene stores, or similar spaces unless such equipment is appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. Inspectors observed lighting installations in battery rooms 26 B and C that were not appropriately rated for the vapors likely to be encountered.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 9 May 2022
Resolution: New lights that meet the vessel's DBA with the CG were sourced and installed in both battery rooms as shown by photographic evidence provided. Appleton Type FLe lights with IEC marking Ex demb IIC T4 Gb and -40°C = Ta = +55°C ambient temperature rating.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 April 2022
Resolved
Persons responsible for actual operations, including owners, operators, contractors, and subcontractors, shall ensure that those operations subject to their control are conducted in compliance with workplace safety and health regulations of this part and, in addition, free from recognized hazards. Inspectors observed a multitude of equipment on the 03 Deck Production Storage Room and Engine Department Storage Rooms not properly secured for expected vessel movement. Examples of the observed hazards included wheeled tool chests free to roll, cabinets not secured from tipping, and assorted industrial valves and equipment not secured on shelving.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2022
Resolved 29 April 2022
Resolution: Received detailed documentation, including photos, from the Master showing satisfactory completion. Pump Room wheeled tool chest secured, one ECR cabinet secured/one removed and Deck 3 equipment secured. Addt'l shelf stowage netting/devices procured.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 11 June 2018
Resolved
Vessel suffered a drift off due to a DP failure. Operator provided DP FMEA's. After review by CG ENG it was found that FMEA's did not address root cause. Vessel required to operate in open bus configuration until further notice.
Action required: 705 - Other - as specified
Due 22 August 2018
Resolved 10 April 2019
Resolution: Upon completion of FMEA and MCS review of results, deficiency has been rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 May 2018
Resolved
Davit arm autmoatic stop limit switch was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2018
Resolved 22 May 2018
Resolution: Recieved Lloyds report of correction of deficiencies.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 1 May 2018
Resolved
Vessel did not have proper annex VI / NOX tech files or parts change out.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2018
Resolved 22 May 2018
Resolution: Recieved report from Lloyds stating def's have been cleared.
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 5 October 2016
Resolved
DG #3 & #4 were unable to be tested upon complete of yard work. Must be tested prior to connecting to DP system
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 October 2016
Resolution: Received Class approval for completion of work on said equipment and successful testing.
Engineering › Thrusters › Seal
Issued 5 October 2016
Resolved
seals were replaced during 2016 D/D. Proof testing must be completed prior to production
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 October 2016
Resolution: Received Class approval for completion of work on said equipment and successful testing.
Lifesaving › Launching Appliances › Winch Brake
Issued 13 May 2016
Resolved
The brakes for lifeboats #1 and #4 stuck when operated in the presence of the MI. Provide prrof of davit brakes operating correctly. [46 CFR 109.301(a)] 50c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2016
Resolved 31 May 2016
Resolution: Received e-mail w/ attached service report from Port Engineer [name withheld] Guesno approved repair work a cleared deficiency.
Lifesaving › Inflatable Liferafts › Float Free
Issued 13 May 2016
Resolved
The liferafts on the aft mooring decks are constrained in their ability to float free by the overhead of the deck above. Shall rectify at upcoming drydock. [46 CFR 108.525 (a)(2)] 17c-from drydock]
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2016
Resolved 24 July 2016
Resolution: Received email from Port Engineer with reason why aft life rafts may be in an obstructed position. SOLAS Chap. III reg. 31.1.4 allows arrangement.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 19 May 2014
Resolved
A Class Doors throughout vsl are not self-closing. A Class doors need to be self closing.
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 18 July 2014
Engineering › Thrusters › Tunnel
Issued 19 May 2014
Resolved
Covers/guards need to be installed on rotating machinery. All three aft thrusters and two forward drop down thrusters need guards installed.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 18 July 2014
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 19 May 2014
Resolved
Galley shutter was also not self closing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2014
Resolved 18 July 2014
Lifesaving › Launching Appliances › Hand Gear
Issued 19 May 2014
Resolved
Lifeboat #1 hand crank interlock switch was inoperable. A means must be provided to disconnect power to the winch before a hand crank can be engaged with the winch operating shaft.
Action required: 705 - Other - as specified
Due 26 May 2014
Resolved 19 May 2014
Resolution: Corrected prior to CG departure from vsl.
Lifesaving › Launching Appliances › Falls
Issued 24 May 2012
Resolved
Missing proof of fall renewal dates, provide statement of fact from class that the falls have been renewed within the last 4 years
Action required: 705 - Other - as specified
Due 24 June 2012
Resolved 5 June 2012
Resolution: Provided letter of fact from class
Lifesaving › Launching Appliances › Release Mechanism
Issued 24 May 2012
Resolved
Missing proof of release gear weight test, provide statement of fact or 3rd party cert that the weight test has been conducted within the last 5 years.
Action required: 705 - Other - as specified
Due 24 June 2012
Resolved 5 June 2012
Resolution: Provided letter for fact from Class
Engineering › Pressure Vessel › Relief Valve
Issued 24 May 2012
Resolved
Missing proof of inspection of PRV for PV's, provide statement of fact from Class or 3rd party cert that the relief valves have been tested.
Action required: 705 - Other - as specified
Due 24 June 2012
Resolved 5 June 2012
Resolution: Relief valve test conducted by crew. Recieved signed letter from Chief Engineer along with pictures to prove that the test was completed
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 24 August 2011
Resolved
Troubleshoot and repair lifeboat # 4 positive pressure air system. Boat to be placed out of service until repairs are completed. The max POB is limited to 60 until boat repaired.
Action required: 705 - Other - as specified
Due 24 September 2011
Resolved 16 September 2011
Electrical › Electric Supply System (service) › Cable
Issued 24 August 2011
Resolved
Survey as required the removal of plastic zip ties from electrical cabling and replace with metal banding.
Action required: 705 - Other - as specified
Due 24 September 2011
Resolved 9 November 2011
Resolution: Rcvd supporting documentation that deficiency has been cleared.
Electrical › Electric Supply System (service) › Cable
Issued 24 August 2011
Resolved
Survey as required the removal of dead end wires from machinery spaces
Action required: 705 - Other - as specified
Due 24 September 2011
Resolved 9 November 2011
Resolution: Rcvd supporting documentation that deficiency has been cleared.