MAURY USCG vessel records
← All vessels

CHEM MIA

CHEM MIA is a 2008 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in January 2026, along with 14 deficiencies and 4 operational controls.

Records from 2016 to 2026. Most recent: operational control imposed, 27 January 2026.

Built
2008
Last inspected
27 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 January 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9407093
988171
Flag
LIBERIA
Maury page id
psix-988171

Documentation record

Tonnage as PSIX records it11645 - Convention (Subpart B), Gross Ton
6326 - Simplified, Net Ton
6326 - Convention (Subpart B), Net Ton
25180 - Displacement, Metric Ton
19702 - Dead Weight, Metric Ton
11645 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

27 January 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8302407
25 October 2025 PSC C · COC-CHEM & TVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8254426
28 July 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8196905
2 October 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8013113
1 March 2022 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7399715
16 November 2021 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7351763
6 January 2021 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7116492
8 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7000597
5 April 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6935593
14 January 2020 COC-CHEM & TVE Annual · ISPS Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6884458
15 October 2019 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6834840
11 December 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6595400
29 November 2017 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6314018
25 October 2016 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6029911

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 14 January 2020 Resolved
Ships shall carry at least 2 fire fighter outfits & 2 additional outfits on tankers. Fighters outfits shall consist of protective clothing of material to protect skin from heat radiating from fire & from burns & scalding by steam. The vessel has four fire fighter outfits on board. One suit is missing three snaps, preventing closure of jacket, leaving crew members skin exposed to heat & flame.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 January 2020
Resolved 14 January 2020
Resolution: Vessel was able to supply additional Firefighter outfit to take place of dammaged outfit.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 11 December 2018 Resolved
Where davit arms are recovered by power safety devices shall be fitted, which will automatically cut off the power. Limit switch on port side davit arrangement was not operating as intended and not cutting power to the davit arms when activated. 17ac - 74SOLAS14 CH III Reg. 34 LSA CH VI 16.1.2.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2018
Resolution: Class Report recieved Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 11 December 2018 Resolved
Emergency escape breathing devices shall comply with the fire safety systems code. EEBD indicator was not in the acceptable "green" zone. EEBD was no suitable for use. 17ac - 74SOLAS14 CH II-2 Reg. 13.3.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2018
Resolution: Class Report recieved Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 December 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. Fixed deck foam line (FR130-135) is missing or does not have proper gasket between hydrant hose connection and fixed foam line. PSCO observed water leaking from the connection point. 17ac - 74SOLAS14 CH I Reg. 11
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2018
Resolution: Class Report recieved Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 December 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO observed missing wire net on 02 out of 04 fuel tank vents on No. 01 Fuel Oil Tank (fwd, FR 182-188). As per the vessel schematics onboard all oily tank vents shall have wire net installed on vents. 17ac - 74SOLAS14 CH1 Reg. 11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2018
Resolution: Class Report recieved Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 December 2018 Resolved
Firefighting outfits shall comply with the Fire Safety Systems Code. The firefighting suits shall protect the skin from radiating heat and the outer surface shall be water resistant. PSCO observed one suit in which the pants have worn and had lost its water resistant material. On an additional suit the pair of gloves did not have water resistant material on the seam. 17ac - 74SOLAS14 CH II-2 Reg. 10.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2018
Resolution: Class Report recieved Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 December 2018 Resolved
Where "B" class divisions are penetrated for passage of electrical cables, pipes, trunks, ducts ets. Arrangement shall be made to ensure that the fire resistance is not impaired. PSCO observed an after survey installation of WiFi cables in the electrical and cable space on A deck. As well as two hole penetrating the bulkhead above the door. The WiFi cables and holes were not filled with an intumescent material, calling into question the fire resistance of the space. 17ac - 74SOLAS14 CH II-2 Reg. 9.3.3.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2018
Resolution: Class Report recieved Deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2018 Resolved
The condition of the ship and its equipment shall be maintained with the provisions of the present regulations. PSCO observed unapproved electrical installation in crews wash room. main power to laundry machine appears to have been reconfigured without proper approval from class. 74SOLAS 14 I Reg. 11
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 December 2018
Resolution: Washing machine removed from laundry space. Photographic evidence and Class Report provided.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 11 December 2018 Resolved
Each complete page of the garbage record book shall be signed by the master of the ship PSCO observed multiple pages in the Garbage Record Book not signed by master assigned to vessel at the time of entries. MARPOL ANNEX V Reg. 9.3(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 December 2018
Resolution: Signed pages and class report provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 December 2018 Resolved
Paint Lockers shall be protected by a water spraying or prinkler system. Flammable material in the paint locker is being stored above the fixed sprinkler nozzles calling into question the ability of fixed firefighting system in the space. 74 SOLAS 14 II-2 reg. 10.6.6.3
Action required: 10 - Deficiency Rectified
Due 11 December 2018
Resolved 11 December 2018
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 December 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea withoutdanger to the ship or persons onboard. during the deckwalk the PSCO observed several areas on the raised deck walkway where the walkway was loose and creating a possible hazard for crew members working on deck. 74 SOLAS 14 I reg. 11
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 December 2018
Resolved 11 December 2018
Documentation › Logs/Records › Garbage Recordkeeping
Issued 29 November 2017 Resolved
2120: Every ship shall carry a Garbage Management Plan which the crew shall follow. The Garbage Plan is not being followed. Food waste was found mixed with other garbage and paper at the final collection point prior to being discharged into the sea. Crew has disposed of food waste 24 time since last port believed to be mixed with other items other than food, MARPOL V/10, 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 30 November 2017
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Ship Superintended
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 29 November 2017 Resolved
2150: Vessels must maintain a Ballast Water Management Plan that has been developed specifically for the vessel what will allow those responsible for the plan to understand and follow it. Vessel is not documenting item in the Ballast Water Management Plan to include Bio-Fouling as required by 33 CFR 151.2050(g) Reference IMO MEPC Resolution 207(62), 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 30 November 2017
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Ship Superintendent.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 29 November 2017 Resolved
1830: Transfer procedures must meet requirements of 33CFR155.750. The vessel did not have the proper transfer procedures as required by 33CFR155.750, 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 30 November 2017
Resolution: Discussed with the Captain, [name withheld], Chief Engineer and Ship Superintendent. Reviewed and gave them a sample copy / format.

Ownership record