ZOBU START is a 2008 tank ship. The Coast Guard has recorded 21 inspections since 2016, most recently in December 2024, along with 2 deficiencies and 2 operational controls.
Records from 2016 to 2024. Most recent: inspection, 7 December 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it26911 - Convention (Subpart B), Gross Ton 13704 - Convention (Subpart B), Net Ton 47186 - Dead Weight, Metric Ton 13704 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 21
7 December 2024COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8044582
6 December 2024PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8042554
5 December 2024Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8043765
2 July 2023COC-TVE Annual · Administrative Inspection
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 December 2024Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT INCLUDING THOSE ONBOARD TANKERS UNLESS THE ADMINISTARTION IS SATISFIED THAT SUCH EQUIPMENT IS APPROPRIATELY CERTIFIED FOR SAFE USAGE IN VAPOURS LIKELY TO BE ENCOUNTERED. PSCO OBSERVED 05 CRACKED IGHTS IN THE CARGO PUMP ROOM.
74SOLAS(04) II-1/45.10.4
16AC
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2024
Resolved 7 December 2024
Resolution: Vessel Crew has removed and replaced 05 defective lights. Files uploaded into documents under defs.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 6 December 2024Resolved
THE SYSTEM SHALL BE CAPABLE OF DELIVERING INERT GAS TO THE CARGO TANKS AT A RATE OF AT LEAST 125% OF THE MAXIMUM RATE OF DISCHARGE CAPACITY OF THE SHIP EXPRESSED AS A VOLUME. PSCO OBSERVED THE NO. 2 INERT GAS BLOWER INOPERABLE.
74SOLAS(20) II-2/4.5.5.1.3
07FSS 15.2.2.1.2
40AC
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 December 2024
Resolved 14 December 2024
Resolution: Vessel provided Class report stating the IG blower has been repaired to the satisfation of class. Class report has been uploaded into documents.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.