Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Maury page id
psix-988978
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 5 August 2014Resolved
All vessels must have draft marks plainly, legibly and contrasting to hull color.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 6 August 2014
Resolution: Barge painted contrasting colors for the draft marks. All sat.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 5 August 2014Resolved
Replace pressure gauge on vapor control line. Gauge is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2014
Resolved 6 August 2014
Resolution: Vessel rep replaced inoperable gauge. All sat.
Vessels prime mover and emergency shutdown is not able to be tested due to fuel lines not being installed at the time of inspection.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2013
Resolution: Vessel completed repairs to the prime mover fuel system, and proved proper operation to the satisfaction of the attending USCG Marine Inspector.
Engineering › Steam System (auxiliary) › Valve, Relief
Issued 18 July 2012Resolved
Steam-line Pressure Relief Valve is inoperative. O/O notified of discrepancy and corrective action needed. CG-835 issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2012
Resolution: Replaced relief valve with new.