← All vessels
CONTSHIP LUV
CONTSHIP LUV is a 2008 freight ship. The Coast Guard has recorded 35 inspections since 2008, most recently in August 2024, along with 27 deficiencies and 9 operational controls.
Records from 2008 to 2024. Most recent: inspection, 19 August 2024.
- Built
- 2008
- Last inspected
- 19 August 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 27 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9406934 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5BHB6
989026
Flag
CYPRUS
—
Maury page id
psix-989026
Inspections, by type
…with no type recorded15
Years with a record
11 calendar years (2008–2024)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9957 - Convention (Subpart B), Gross Ton
5032 - Convention (Subpart B), Net Ton
18938 - Displacement, Metric Ton
13714 - Dead Weight, Metric Ton
9957 - Simplified, Gross Ton
5032 - Convention (Subpart B), Net Ton
18938 - Displacement, Metric Ton
13714 - Dead Weight, Metric Ton
9957 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 35
19 August 2024
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7977259
16 August 2024
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7982786
27 January 2024
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7853130
23 May 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7457256
6 May 2022
PSC B · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7445188
12 March 2022
PSC B · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7410577
18 February 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7398408
29 January 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7387576
7 January 2022
PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7376886
23 November 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7356402
23 November 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7356422
28 October 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7341659
8 October 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7329387
16 September 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7313736
27 August 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7298421
6 August 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7279200
5 May 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7190359
22 March 2021
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7160690
23 October 2020
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7080683
29 April 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6671483
15 April 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6661668
27 December 2018
ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6603123
23 July 2018
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6488387
20 July 2018
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6485239
15 April 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6391905
2 September 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6257355
7 July 2017
ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6199265
14 April 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6123718
12 April 2016
MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5850084
14 September 2015
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5719780
14 September 2015
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5724447
12 June 2012
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4341603
4 November 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3355802
4 November 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3357221
2 November 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3355159
Deficiency record · 27
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2022
Resolved
FIRE DETECTORS SHALL BE TESTED ACCORDING TO STANDARDS EN-E4-10:2001 AND IGC 60092-504.
CREW DOES NOT HAVE APPROVED EQUIPMENT FOR FIRE DETECTOR TESTING ONBOARD.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2022
Resolved
NOZZLES SHALL BE OF AN APPROVED PURPOSE TYPE (I.E. SPRAY/JET TYPE) INCORPORATING A SHUTOFF.
THE NOZZLES ONBOARD WERE TESTED BY [name withheld] WOULD NOT PROPERLY TRANSITION FROM JET.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 18 February 2022
Resolved
The arrangements provided shall be such as to ensure that the safety of the ship in all sailing conditions, including maneuvering, is equivalent to that of a ship having the machinery spaces manned. Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that the satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation.
Vessel's Main Engine Control Panel and valve operation monitoring system are partially inoperable. Vesel currently depends on one monitoring screen for visual identification of parameters which restricts its ability to operate minimally manned. (74 SOLAS (04) II-1/46.1&2)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 February 2022
Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. The front of switchboards shall be sufficiently guarded.
Main switchboard has several newly installed breakers which differ in size from original breakers. These have created open slots to the feeding power rails which creates access to live electrical hazards. (74 SOLAS (04) II-1/45.2)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 February 2022
Resolved
A fixed fire detection and fire alarm system shall be installed in periodically unattended machinery spaces.
Forward fire detector head over the main engine was observed missing. (74 SOLAS (04) II-2/7.4.1.1)
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 January 2022
Resolved
PSCO observed both of the vessel's fire fighter outfits to be fraying around the neck and underarms. Making them inadequate to protect skin from the heat of a fire.
74SOLAS(04) II-2/10.2.1
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 15 April 2019
Resolved
The annual surveys referred to in paragraph (1)(c)of this article shall be endorsed on the International Load Line Certificate. The vessel's curretn International Load Line Certificate does not mention the last annual survey.
Cite: ICCL 66/88 Article 14(2).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 April 2019
Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. When the Port State Control team witnessed the emergency and main steering test, a 5 degree deviation was onserved and a hydraulic lock alarm was activated as the team tested the #2 steering gear pump.
Cite: SOLAS 2014 Chapter I Reg. 11
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2016
Resolved
Main source of electrical power shall consist of at least two generating sets. Two of the ships three generators are down for maintenance. 74SOLAS(04)II-1/40.1.1
Documentation › Certificates/Documents › IOPP Certificate
Issued 12 April 2016
Resolved
Oil filtering equipment shall be provided with alarming arrangements. The accuracy of equipment shall be verified suring IOPP Certificate renewal. The calibration certificate was unable to be produced at the time of inspection however master did locate and send over via email. MARPOL I/13.7 MEPC 107(49)4.2.11
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 12 June 2012
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Lighting fixture on port side cargo deck at the stairwell to the poop deck has themetal support that is no longer welded to the deck. The wires and support are dangling and could chaff causing an electrical shock hazard. SOLAS 09 II-1/Reg 45.5.5
Lifesaving › Lifebuoys › Immediately Available
Issued 12 June 2012
Resolved
Lifebuoys shall be so distributed as to be readily available and so stowed as to be capable of being rapidly cast loose. Both port and starboard forecastle lifebuoys were not stowed in their assigned locations.
Construction/Loadline › Penetrations › Gasket
Issued 12 June 2012
Resolved
After any survey of the ship under regulation 7,8,9 or 10 had been conducted, no change shall be made....Alteration has been made to wiring running from the radar to bridge through penetration in bulkhead.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 June 2012
Resolved
Doors required to be self closing shall not be fitted with hold back hooks. Multiple self closing A class boundaries are fitted with rope to tie the boundary open. SOLAS II-2/Reg 9.4.2.2
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 12 June 2012
Resolved
Maintenance, testing and inspections shall be carried out based on teh guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire fighting systems and applicances. CO2 bottles throughout the vessel have exceeded the maintenance cycle set by the administration. SOLAS 09 II-2/Reg 142.2.1
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 12 June 2012
Resolved
The purpose of the regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose the following shall be met...ignition sources shall be seperated from combustible materials. Old papers are being stored in direct contact with control panel for bridge lighting.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 June 2012
Resolved
The following fire protection systems shall be kept in good working order: structural fire protection, including fire/A class resisting divisions. Multiple doors throughout the ship were identified as self closing but do not close on their own. SOLAS 09 II-2/Reg 14.2.1.1
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 June 2012
Resolved
No change shall be made in the structural arrangements, machinery, equipment or other items without the sanction of the Administration. A hose has been arranged from the condensation output on the AC unit, thru the wall via small hatch, and is so arranged as to discharge directly overboard. SOLAS 09 I/Reg 11(a)
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 12 June 2012
Resolved
No change shall be made in the structural arrangements, machinery, equipment or other items without sanction of Administration. Flame screens on port side poop deck TH OD Void and Void adjacent to stairwell are wasted. SOLAS 09 I/Reg 11(a)
Operations/Management › Drills/Instruction › Abandon Ship
Issued 12 June 2012
Resolved
Drills shall as far as practicable be conducted as if there were anactual emergency. While crew had knowledge of proceedures and required equipment, no one grabbed any required items as per S.O.P. SOLAS 09 III/Reg 19.3.1
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 June 2012
Resolved
The galley door and stairwell doors are marked as being A-0 doors on teh fire control plan. A-15 doors are fitted into these locations. Door located at the bottom of teh stairwell is warped and does not close at the bottom, the door handle does not function properly, and the top of the door has been drilled thru in order to secure the closing mechanism which negate the fire integrity of this door.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 4 November 2008
Resolved
Operating instructions, including block diagram, for steering gear were not posted on navigating bridge and in steering gear compartment as per SOLAS 74 (amended) Chapter V/26.3.1. Correct to satisfaction of class prior to next US port after sailing foreign.
Operations/Management › Pollution › Ballast Water Management
Issued 4 November 2008
Resolved
Vessel does not have on-board a vessel-specific ballast water management plan as per 33 CFR 151.2035(a)(7).
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 4 November 2008
Resolved
Vessel is not maintaining ballast water recordkeeping in accordance with 33 CFR 151.2045; missing total ballast water information including number of tanks and location of exchange.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 November 2008
Resolved
During rescue boat drill crew was unable to start rescue boat after 20 minutes of attempts. Rescue boat was not in a state of continuous readiness for launch within 5 minutes as per SOLAS 74 (amended) Chapter III/14.1. SOLAS 74 (amended) III/20.2.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 4 November 2008
Resolved
Only copy of SOLAS training manual required by SOLAS 74 (amended) III/35 was kept on bridge, not in each crew messroom, recreation room, or cabin. Master moved manual to crew's messroom until such time as copies are placed in officer messroom and recreation room. SOLAS 74 (amended) III/35.2. Correct to satisfaction of class prior to next US port after sailing foreign.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 4 November 2008
Resolved
SOLAS training manual did not contain vessel-specific information as per instructions in the manual and SOLAS 74 (amended) III/35.3. Correct to satisfaction of class prior to next US port after sailing foreign.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.