MAURY USCG vessel records
← All vessels

CONTSHIP LUV

CONTSHIP LUV is a 2008 freight ship. The Coast Guard has recorded 29 inspections since 2016, most recently in August 2024, along with 10 deficiencies and 7 operational controls.

Records from 2016 to 2024. Most recent: inspection, 19 August 2024.

Built
2008
Last inspected
19 August 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 August 2024
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9406934
989026
Flag
CYPRUS
Maury page id
psix-989026

Documentation record

Tonnage as PSIX records it9957 - Convention (Subpart B), Gross Ton
5032 - Convention (Subpart B), Net Ton
18938 - Displacement, Metric Ton
13714 - Dead Weight, Metric Ton
9957 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

19 August 2024 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7977259
16 August 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7982786
27 January 2024 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7853130
23 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7457256
6 May 2022 PSC B · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7445188
12 March 2022 PSC B · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7410577
18 February 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7398408
29 January 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7387576
7 January 2022 PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7376886
23 November 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7356402
23 November 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7356422
28 October 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7341659
8 October 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7329387
16 September 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7313736
27 August 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7298421
6 August 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7279200
5 May 2021 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7190359
22 March 2021 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7160690
23 October 2020 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7080683
29 April 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6671483
15 April 2019 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6661668
27 December 2018 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6603123
23 July 2018 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6488387
20 July 2018 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6485239
15 April 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6391905
2 September 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6257355
7 July 2017 ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6199265
14 April 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6123718
12 April 2016 MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5850084

Deficiency record · 10

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2022 Resolved
FIRE DETECTORS SHALL BE TESTED ACCORDING TO STANDARDS EN-E4-10:2001 AND IGC 60092-504. CREW DOES NOT HAVE APPROVED EQUIPMENT FOR FIRE DETECTOR TESTING ONBOARD.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 May 2022
Resolution: Vessel ordered and received approved equipment for fire detector testing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2022 Resolved
NOZZLES SHALL BE OF AN APPROVED PURPOSE TYPE (I.E. SPRAY/JET TYPE) INCORPORATING A SHUTOFF. THE NOZZLES ONBOARD WERE TESTED BY [name withheld] WOULD NOT PROPERLY TRANSITION FROM JET.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 May 2022
Resolution: REPLACED NOZZLES WITH FUNCTIONAL TYPE. TESTED BY PSCO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 18 February 2022 Resolved
The arrangements provided shall be such as to ensure that the safety of the ship in all sailing conditions, including maneuvering, is equivalent to that of a ship having the machinery spaces manned. Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that the satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Vessel's Main Engine Control Panel and valve operation monitoring system are partially inoperable. Vesel currently depends on one monitoring screen for visual identification of parameters which restricts its ability to operate minimally manned. (74 SOLAS (04) II-1/46.1&2)
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2022
Resolved 20 February 2022
Resolution: Vessel submitted Flag dispensation allowing vessel to operate with the display inoperable until 04 MAR 2022.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 February 2022 Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. The front of switchboards shall be sufficiently guarded. Main switchboard has several newly installed breakers which differ in size from original breakers. These have created open slots to the feeding power rails which creates access to live electrical hazards. (74 SOLAS (04) II-1/45.2)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2022
Resolved 18 February 2022
Resolution: PSCO observed hazard openings on the switchboard sufficiently covered/guarded prior to departure from the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 February 2022 Resolved
A fixed fire detection and fire alarm system shall be installed in periodically unattended machinery spaces. Forward fire detector head over the main engine was observed missing. (74 SOLAS (04) II-2/7.4.1.1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 March 2022
Resolved 13 May 2022
Resolution: Vessel installed flame detector and submitted correspondence from Flag attesting to recitification.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 January 2022 Resolved
PSCO observed both of the vessel's fire fighter outfits to be fraying around the neck and underarms. Making them inadequate to protect skin from the heat of a fire. 74SOLAS(04) II-2/10.2.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2022
Resolved 7 January 2022
Resolution: Vessel submitted invoice and photos of 02 new fire fighter outfits that were delivered on 07JAN2022.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 15 April 2019 Resolved
The annual surveys referred to in paragraph (1)(c)of this article shall be endorsed on the International Load Line Certificate. The vessel's curretn International Load Line Certificate does not mention the last annual survey. Cite: ICCL 66/88 Article 14(2).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2019
Resolved 29 April 2019
Resolution: Received Class Report attesting to Annual Survey and notation of the inset on the hull.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 April 2019 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. When the Port State Control team witnessed the emergency and main steering test, a 5 degree deviation was onserved and a hydraulic lock alarm was activated as the team tested the #2 steering gear pump. Cite: SOLAS 2014 Chapter I Reg. 11
Action required: 10 - Deficiency Rectified
Resolved 15 April 2019
Resolution: The crew performed satisfactory corrective action on the spot.
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2016 Resolved
Main source of electrical power shall consist of at least two generating sets. Two of the ships three generators are down for maintenance. 74SOLAS(04)II-1/40.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2016
Resolved 12 April 2016
Resolution: Witnessed proper operation of two of the ship's three SSDGs.
Documentation › Certificates/Documents › IOPP Certificate
Issued 12 April 2016 Resolved
Oil filtering equipment shall be provided with alarming arrangements. The accuracy of equipment shall be verified suring IOPP Certificate renewal. The calibration certificate was unable to be produced at the time of inspection however master did locate and send over via email. MARPOL I/13.7 MEPC 107(49)4.2.11
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2016
Resolved 12 April 2016
Resolution: Master was able to produce calibration certificate.

Ownership record