MAURY USCG vessel records Sign in
← All vessels

BLOWN AWAY

BLOWN AWAY is a 2008 passenger vessel (inspected). The Coast Guard has recorded 8 inspections since 2008, most recently in March 2020, along with 12 deficiencies.

Records from 2008 to 2020. Most recent: inspection, 10 March 2020.

Built
2008
Last inspected
10 March 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7572
989082
Flag
UNITED STATES
367394890, 367668720 (licence lapsed)
Maury page id
psix-989082

Inspections, by type

Years with a record 8 calendar years (2008–2020)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2008
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSIESTA KEY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 5 January 2009
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH9500MMSI 367668720 · expired · compulsorily equipped · granted 24 April 2015, cancelled 31 May 2025
WDE7572MMSI 367394890 · expired · compulsorily equipped · granted 12 February 2009, cancelled 20 April 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

10 March 2020 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6928194
26 January 2017 Annual Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6077836
29 February 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5824180
28 February 2012 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4252140
10 February 2011 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3950175
18 February 2010 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3676146
8 April 2009 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3444945
29 October 2008 COI Inspection · Hull Examination · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3353922

Deficiency record · 12

Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 28 February 2017 Resolved
Replace inboard propeller due to excessive pitting on blades. 46CFR184.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2017
Resolution: Propeller replaced with refurbished propeller. Test SAT.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 February 2017 Resolved
Forward bilge high level audible alarm not loud enough to hear while underway. Repair/replace alarm. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2017
Resolution: Alarm replaced in kind. Test SAT.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 28 February 2017 Resolved
Label stowage location of operating station fire extinguisher. 46CFR181.520
Due 14 March 2017
Resolved 16 March 2017
Resolution: Fire extinguisher stowage location properly labeled.
Documentation › Certificates/Documents › FCC SSL
Issued 29 October 2008 Resolved
Provide FCC SSL & Radio Safety Certificate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 29 October 2008 Resolved
Prove location of B-II extinguisher is sat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Navigation › Piloting/Steering › Marine Charts
Issued 29 October 2008 Resolved
Provide Nav Pubs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 October 2008 Resolved
Conduct Machinery Operational test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Communications › Radio Communications › EPIRB
Issued 29 October 2008 Resolved
Provide EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 29 October 2008 Resolved
Prove Proper Operation of VHF
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 29 October 2008 Resolved
Provide Mooring Lines
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 October 2008 Resolved
Conduct drills
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Stability › Freeing Ports › General
Issued 29 October 2008 Resolved
Prove PVC piping for drainage is satisfactory.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009

Ownership record