Records from 2008 to 2020. Most recent: inspection, 10 March 2020.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2008
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSIESTA KEY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 5 January 2009
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
10 March 2020
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6928194
26 January 2017
Annual Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6077836
29 February 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5824180
28 February 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4252140
10 February 2011
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3950175
18 February 2010
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3676146
8 April 2009
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3444945
29 October 2008
COI Inspection · Hull Examination · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3353922
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 28 February 2017
Resolved
Replace inboard propeller due to excessive pitting on blades. 46CFR184.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2017
Resolution: Propeller replaced with refurbished propeller. Test SAT.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 February 2017
Resolved
Forward bilge high level audible alarm not loud enough to hear while underway. Repair/replace alarm. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2017
Resolution: Alarm replaced in kind. Test SAT.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 28 February 2017
Resolved
Label stowage location of operating station fire extinguisher. 46CFR181.520
Due 14 March 2017
Resolved 16 March 2017
Resolution: Fire extinguisher stowage location properly labeled.
Documentation › Certificates/Documents › FCC SSL
Issued 29 October 2008
Resolved
Provide FCC SSL & Radio Safety Certificate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 29 October 2008
Resolved
Prove location of B-II extinguisher is sat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Navigation › Piloting/Steering › Marine Charts
Issued 29 October 2008
Resolved
Provide Nav Pubs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 October 2008
Resolved
Conduct Machinery Operational test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Communications › Radio Communications › EPIRB
Issued 29 October 2008
Resolved
Provide EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 29 October 2008
Resolved
Prove Proper Operation of VHF
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 29 October 2008
Resolved
Provide Mooring Lines
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 October 2008
Resolved
Conduct drills
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009
Stability › Freeing Ports › General
Issued 29 October 2008
Resolved
Prove PVC piping for drainage is satisfactory.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2009