Records from 2011 to 2026. Most recent: inspection, 21 May 2026.
Inspection history · 43
21 May 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8383754
10 April 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8103225
19 September 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8005928
15 June 2024
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7935357
15 June 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7938842
7 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7908649
27 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7676147
10 February 2022
Internal Structural Exam · Deficiency Check · In-Service Inspection · Annual Inspection · Examination of Repairs · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7394271
19 May 2021
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7201404
24 February 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7143186
13 December 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7121124
13 July 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7005231
13 May 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6943534
14 April 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939235
9 April 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6977812
18 February 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6911154
10 January 2020
DAPI Audit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891841
12 November 2019
Deficiency Check · In-Service Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6873113
31 October 2019
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6847415
30 September 2019
Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6825012
30 September 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6825043
4 September 2019
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6804171
12 August 2019
Plan Review "T" Boat · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6792790
30 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6675028
17 February 2019
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6627400
7 September 2018
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6571799
11 July 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6493621
11 June 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6441993
11 June 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6442500
4 June 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6433988
2 June 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6493597
9 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6410524
8 March 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6453879
19 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6327288
16 December 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6326222
16 December 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6348045
26 October 2017
Examination of Repairs · Plan Review "T" Boat · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6295679
20 June 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6181859
20 June 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6223669
8 May 2017
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6141487
8 May 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6145061
30 March 2017
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6118943
11 February 2016
COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5813932
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Observed exposed electric cables for thruster in the portside engine room. Rectify cables condition to the satisfaction of the MI. (46 CFR 183.200(b))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 9 May 2025
Resolution: Received satisfactory photo of encased cables' condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 April 2025
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 degrees Celsius (150 degrees Fahrenheit), must be suitably insulated where necessary to prevent injuries. Observed the exhaust lagging was deteriorated, leaving hot piping exposed in the portside engine room. Replace exhaust lagging and cover the hot pipe surface to the satisfaction of the MI. (46 CFR 177.970)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 9 May 2025
Resolution: Received satisfactory photo of newly installed exhaust lagging.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 April 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Observed a combination of both child and adult life jackets in the same starboard life jacket box. Separate and clearly mark their different locations to the satisfaction of the MI. (46 CFR 180.78)(a)(5))
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 21 April 2025
Resolution: Received satisfactory photos of properly separated life jacket sizes.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 April 2025
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Observed that a number of life jackets were marked "REAL MCCOY" or without any marking. Properly mark life jackets "REAL MCCOY II" to the satisfaction of the MI. (46 CFR 185.604)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 21 April 2025
Resolution: Received photos of satisfactorily marked life jackets onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 April 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Observed that both life ring buoy's waterlight batteries were expired. Replace batteries to the satisfaction of the MI. (46 CFR 180.70(d)(1))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 21 April 2025
Resolution: Photos of new batteries installed were provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 10 April 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Observed that the FCC Radio Station Authorization was expired. Replace with new, valid certificate to the satisfaction of the MI. (46 CFR 184.502)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 23 April 2025
Resolution: Received official copy of valid FCC Radio Station Authorization.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 April 2025
Resolved
The master shall have appropriate "NO SMOKING" signs posted and shall take all necessary precautions to prevent smoking or carrying of lighted or smoldering pipes, cigars, cigarettes, or similar items in the deck area assigned to automobiles or other vehicles. Observed that the signage on the starboard side was severely faded. Replace sign to the satisfaction of the MI. (46 CFR 185.340 (c))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 21 April 2025
Resolution: Received photo of satisfactory "NO SMOKING" signage onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported they collided with an unknown object causing the steering motor shaft to break. Vessel restricted from movement until attending MI conducts satisfactory ISE and witnesses operational test of propulsion system.
46 CFR 182.200(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2024
Resolution: MI attended in person, observed new stearing motor shaft replaced and SAT operational test underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 June 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced a loss of propulsion on both engines, resulting in an unintentional grounding. Provide root cause, corrective actions, and detailed damage assessment to the satisfaction of the MI.
46 CFR 182.200(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2024
Resolution: Vessel conducted sat sea trials in presence of MI.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 May 2024
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel unable to provide satisfactory firefighting servicing report for fixed-Co2 systems. Provide firefighting servicing report for #1 ENG space and #2 ENG space Co2 systems to satisfaction of attending marine inspector. Provide servicing report within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2024
Resolved 21 May 2024
Resolution: Operator provided servicing report.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 May 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of extinguishers required on a vessel must be acceptable to the OCMI, but must not be fewer that the minimum number required by Table 181.500(b). Pilot house portable extinguisher missing. Provide proper extinguisher within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2024
Resolved 21 May 2024
Resolution: Portable installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 May 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Marine inspector observed expired medications and eyewash in first aid kit on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 22 August 2024
Resolution: Received photographs of replaced medications
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2024
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Several adult lifejackets had failing retro tape that needs repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 22 August 2024
Resolution: Received photograph of replaced lifejackets
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 April 2023
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel unable to provide satisfactory firefighting servicing report for fixed-Co2 systems. Provide firefighting servicing report for #1 ENG space and #2 ENG space Co2 systems to satisfaction of attending marine inspector.
46 CFR 176.810 (b) (2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 17 August 2023
Resolution: Servicing report onboard vessel at time of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 April 2023
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. 02 of vessels ring life buoys are missing vessels name. 01 ring life buoy is faded. Provide proper marking of vessel name on each ring life buoy.
46 CFR 185.604 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 23 June 2023
Resolution: Bouy correctly marked w/ vessels name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery including the following: inspection of all machinery essential to the routine operation of the vessel. Associated operation manuals for HUG Diesel Particulate Filter (DPF) all state hard copies of manuals must be near the system at all times. Manuals for system were not available onboard. Provide required copies of all manuals onboard.
46 CFR 176.804
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 17 August 2023
Resolution: Copies of DPF manuals on board at time of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery including the following: inspection of all machinery essential to the routine operation of the vessel. Operations manuals for HUG DPF system refer to maintenance requirements and state certain functions (A work) must be done by HUG Engineering AG or an authorized partner. Maintenance records were not available for inspection. Provide maintenance records and qualifications of personnel conducting any maintenance A work.
46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 23 October 2023
Resolution: Guidance provided to operator to maintain maintenance records in the future and provide for inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery including the following: inspection of all machinery essential to the routine operation of the vessel. HUG DPF system onboard was commissioned to run with regeneration burner automatically running burning cycle at 15 hours. Crew stated DPF system is unable to auto run due to hydraulic demands of DPF in addition to other hydraulicly powered systems onboard. Operators currently have mechanics come onboard bi-weekly to manually run regeneration burner. Provide records of bi-weekly regeneration operation and details in accordance with manufactures instructions that this is a suitable method for operating these units.
46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 17 August 2023
Resolution: Manual regeneration maintenance logged in vessels log at time of inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 27 April 2023
Resolved
Each lighting fixture globe, lens, or diffuser must have
a guard or be made of high strength material. Light above #1 ENG has broken guard. Install proper guard to satisfaction of Marine Inspector.
46 CFR 183.410
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2023
Resolved 18 August 2023
Resolution: Operator provided photos of new lights w/ covers installed. Attached to docs tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of machinery, fuel, and piping systems, including the following: (a) operation of the main propulsion machinery both ahead and astern. Vessel unable to complete underway portion of annual inspection due to maintenance of #1 ENG coolant line. Complete satisfactory underway portion of annual inspection, including Man Overboard drill to satisfaction of attending Marine Inspector.
46 CFR 176.804 (a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 August 2023
Resolution: Completed underway portion of annual inspection and man overboard drill.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Prior to inspection, Master of the vessel discovered a small leak on #1 ENG coolant piping via associated reduced pressure alarm. Vessel completed repairs to satisfaction of attending Marine Inspector.
46 CFR 182.200 (a)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 27 April 2023
Resolution: Vessel completed repairs to satisfaction of attending MI.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 May 2022
Resolved
The frame or suppoer of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permantently attached to a bulkhead or deck. MI discovered 02 portable fire eztinguishers not properly mounted.
46 CFR 181.500(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 27 April 2023
Resolution: Portables properly mounted.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 February 2021
Resolved
Employers must maintain records of chemical tests and must make these records available to the Coast Guard upon request.
Vessel operator noted that the records were kept in their business office in Sacramento, not accessible for the inspectors to review during the inspection.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 19 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 February 2021
Resolved
A vessel must carry a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. Vessel's kit was missing ammonia inhalants and aspirin.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 21 April 2021
Resolution: Received verification inhalants and aspirin replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Dead end wires under pilot house chart table.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Provided photos of fixed electrical wires
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 24 February 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Provided proof of Radio Station license documentation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2020
Resolved
All Machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Vessel’s service generator was not present at the time of its annual inspection.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2020
Resolved 16 June 2020
Resolution: Original generator installed IAW 46 CFR 182.100.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2020
Resolved
If an individual holding a credential fails a chemical test for dangerous drugs, the individual's employer must report the test results in writing to the nearest Coast Guard Officer in Charge of Marine Inspection (OCMI). CAL TRANS internal policy stated all mariners who receive positive chemical tests were placed into company-inposed treatment and rehabilitation program prior to being placed back into a safety sensitive position. Notification to USCG was not taking place. Therefore, the mariner was not subject to suspension and revocation proceedings against his or her credential under 46 CFR part 5.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2020
Resolved 10 February 2020
Resolution: Marine Employer DAPI program updated to reflect regulatory compliance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 February 2019
Resolved
At every vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Uncontrolled leak of hydraulic fluid from failed O-ring and fitting on the "A" line of the #1 main diesel engine. Vessel prohibited to carry passengers for hire until satisfactory operational tests are observed by USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2019
Resolved 26 February 2019
Resolution: Conducted satisfactory operational test of replacement hydraulic coupler with no hydraulic leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 February 2019
Resolved
A vessel must be operated in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel crew have submitted numerous inspection reports over the previous months to owner/operator stating consistent hydraulic leaking from #1 thrustmaster at s/s block where the affected fitting and o-ring are located. Master notified company of ongoing leaks and maintenance failures within the "A" hydraulic line. Company did not provide any repair or maintenance oversight despite frequent daily inspection reports from crew. Crew recognized inherent danger for pollution and potential loss of propulsion due to drop in hydraulic pressure. Crew forced to mitigate risk to vessel, personnel and environment by installing absorbent pads around the leaks. In spite of crew submitted inspection reports and attempts to mitigate the failure, catastrophic failure occurred on the #1 main propulsion engine "A" hydraulic line fitting and O-ring. Preliminary review of crew-submitted daily vessel inspection reports to company show the failures within the hydraulic lines have been known since at least November 6th 2018.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2019
Resolved 4 April 2019
Resolution: Conducted meeting to discuss future maintenance plans.
Fire Fighting › Fire Pumps › Arrangement
Issued 11 June 2018
Resolved
Repair Fire/ bilge pump pilot line of the pressure compensating valve for the auxiliary hydraulic valve stack. 46 CFR 181.300
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 June 2018
Resolved 11 June 2018
Resolution: Replaced pilot line; tested pump; all sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 May 2018
Resolved
Instrumentation cable bundling, in both engine rooms, is zip tied to and resting on the main engines. The cabling must be hoisted and supported by a metal bracket.
46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2018
Resolved 15 May 2018
Resolution: Received photos showing that electrical wires were removed from vessel as they are not a part of a permanent installation. Cabling will be kept off the vessel except when running engine diagnostics.
Engineering › Non-conventional Propulsion/Steering › Installation Block (Azipod)
Issued 19 December 2017
Resolved
Vessel has significant leakage from #1 propeller swivel block and requires effective repairs IAW 46 CFR 182.100.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2017
Resolved 19 December 2017
Resolution: Operator provided technical report and photographic evidence of repairs.
Engineering › Bilge Water Management System › Pump
Issued 16 December 2017
Resolved
Vessel's auxiliary hydraulic pump leaks fluid and requires repair IAW 46 CFR 182.100.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2017
Resolved 16 December 2017
Resolution: Operator provided statement and technical note attesting to proper repairs.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Unit (Azipod)
Issued 26 October 2017
Resolved
Prove proper operation of azimuthing drive system following repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2017
Resolution: New hydraulic pipe installed and tested with no leaks.
Engineering › Thrusters › Hose
Issued 20 June 2017
Resolved
Provide repair description for failed hydraulic system components. Prove proper operation of system after completion of repairs in the presence of a marine inspector, in accordance with 46CFR176.700(a)(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2017
Resolved 21 June 2017
Resolution: Attended vessel to witness proper operation of the #1 Thruster. All Sat.
Engineering › Steering Gear System › Piping
Issued 8 May 2017
Resolved
Loss of propulsion/steering on #2 MDE due to hydraulic accumulator. Remove port and starboard accumulators, reconfigure hydraulic system as originally designed, prove proper operation of port & starboard propulsion and steering systems under power.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2017
Resolved 8 May 2017
Resolution: Port/Starboard accumulators removed. System piping/hoses returned to original design. Sea Trial successful. Vessel returned to service.
Engineering › Steering Gear System › Hydraulic Hose
Issued 8 May 2017
Resolved
Provide plan proposal for accumulators with safety mechanism to prevent accidental loosening from vibration, such as safety wire, for review prior to installation.
Action required: 705 - Other - as specified
Resolved 12 August 2019