MAURY USCG vessel records
← All vessels

LIGHTNING

Built
2000
Last inspected
13 April 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-9891

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

13 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8303859
1 October 2025 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8236857
3 September 2024 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7995386
23 April 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7873515
21 August 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7751597
10 August 2022 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7516714
25 April 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7421284
3 June 2021 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7211991
10 September 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7056055
28 April 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6949649
9 September 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6808649
21 May 2019 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6689339
6 September 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6534925
20 April 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6398086
13 September 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6275193
14 June 2016 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5902419
14 April 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5854887

Deficiency record · 11

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 6 September 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Owner/Operator did not have emergency instructions as outlined in this regulation. Must provide CG with emergency instructions that means this regulation's requirements. 46 CFR 185.510(a)
Action required: 10 - Deficiency Rectified
Resolved 6 September 2024
Resolution: Owner/Operator provided emergency instructions to be used for the vessel's crew.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 September 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel's First-Aid Kit was expired, must provide proof of replacement and/or updated to existing First-Aid kit to CG. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 September 2024
Resolution: Owner/Operator provided photo of new First-Aid Kit purchased.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 September 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Owner/Operator requested an annual inspection beyond the 3 months window sited in this regulation. Resulting in the deactivation of the vessel's COI. Vessel in not authorized to operator as a certified vessel until a Renewal COI inspection is completed. 46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 September 2024
Resolved 6 September 2024
Resolution: Completed Renewal COI inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2020 Resolved
A submersible electric bilge pump shall be provided with a positive control action valve at the hull penetration. The bilge lines lacks a positive control valve.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 14 September 2020
Resolution: The new valves was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2020 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3ft in length but not more than 6 ft, securing the waterlight around the body of the ring life buoy. The lanyard attached to the waterlight is less than 3ft.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 14 September 2020
Resolution: A new lanyard was installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 September 2018 Resolved
TJT01- First aid kit had expired items, required kit to be restocked with serviceable aspirin, eye wash and burn cream; 46CFR184.710, corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 20 September 2018
Resolved 6 September 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 September 2018 Resolved
TJT02- Provide horn for VSL, air horn on-board was empty and did not work, COLREGS 33; corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 6 September 2018
Resolved 6 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 September 2018 Resolved
TJT03- Hose clamps missing on bilge piping, clamps required on vital bilge system, 46CFR182.730; corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 6 September 2018
Resolved 6 September 2018
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 September 2018 Resolved
TJT04- Fire buckets need to be labeled, labels were not on them; 46CFR181.610 corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 6 September 2018
Resolved 6 September 2018
Communications › Alarms/Indicators › High Water Alarm
Issued 13 September 2017 Resolved
HI water alasrm was inop, replaced on the spot
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2017
Resolved 13 September 2017
Resolution: HI water alasrm was inop, replaced on the spot
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 14 June 2016 Resolved
Issued 835 to replace all fuel hoses with J-1942 and proper fittings by 15JUL16; 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 11 August 2016
Resolution: new fuel lines and racor.

Ownership record