A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 February 2012
Resolved
Center light (white) for not under command lights was duct taped together and not functional
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2012
Resolution: replaced light.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 28 February 2012
Resolved
Vsl did not have a copy of the last DAPI audit on board
Due 29 April 2012
Resolved 30 April 2012
Resolution: Port Capt. provided report.
Documentation › Logs/Records › Logbook (official)
Issued 28 February 2012
Resolved
Vsl's log was missing required information, steering, propulsion checks ect...
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2012
Documentation › Logs/Records › Logbook (official)
Issued 28 February 2012
Resolved
Vsl did not have a record of safety equipment maintaince
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2012
Resolution: Provided record.
Documentation › Logs/Records › Logbook (official)
Issued 28 February 2012
Resolved
Vsl did not have stability calculations logged
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2012
Resolution: completed.
Engineering › Compressed Air System (start air) › Valve
Issued 28 February 2012
Resolved
Safety relief valve needs to be tested or replaced
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2012
Resolution: Replaced valves.
Construction/Loadline › Structures › Ventilators
Issued 28 February 2012
Resolved
Label vent closures "close in case of fire"
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2012
Resolution: completed.
Fire Fighting › Firemans Outfit › Axe
Issued 28 February 2012
Resolved
Ax needs to be labled with vsl's name
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2012
Resolution: completed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 February 2012
Resolved
Outlet boxes in the engine room did not have waterproof covers for the outlets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2012
Resolution: completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 28 February 2012
Resolved
Vsl needs to provide a third party report verifying the completion of service to the fixed CO2 system
Due 30 March 2012
Resolved 2 March 2012
Resolution: provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 February 2012
Resolved
Vsl failed man overboard drill. Vsl captain is required to conduct training and perform man overboard, fire and abandon ship drills in the presence of a MI
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2012
Resolution: completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2011
Resolved
Provide shielding for all wiring coming from three portable generators on back deck. Wiring is lying all around the back deck and is a significant hazard to crew and others.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 5 January 2011
Resolved
Provide grease tape to protect flexible hose fitings for all CO2 bottles on the back deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Fire Fighting › Means of Escape › Blocked
Issued 5 January 2011
Resolved
Reroute wiring that is blocking aft door on "Martin" portable qtrs on back deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 January 2011
Resolved
Provide fixed smoke detectors that alarm on the bridge for two conex boxes on the aft deck, on box has an office space in it and the other box has an working washer/dryer and supplies stored.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Fire Fighting › Structural - A Class Divisions › Workshops
Issued 5 January 2011
Resolved
Provide proper thru-bulkhead penetration system for wiring going into forward and aft bulkheads of [name withheld] on aft deck. Cat-5 and electrical wiring is currently running thru open holes in A-60 bulkheads.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2011
Resolved
Provide metal/fireproof supports for all overhead wiring of back deck and inside portable workspaces, every 24".
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Communications › Alarms/Indicators › General Alarm
Issued 5 January 2011
Resolved
Demonstrate proper operation of general alarm system on vessel. Vessel GA does not ring anywhere on vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 5 January 2011
Resolved
Mount fire alarm on the bridge for Martin portable qtrs, alarm is already installed but is lying inside storage cabinet on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 5 January 2011
Resolved
Since MISLE doesn't offer but two components for emergency steering I am forced to write it here. Provide detailed instructions for swapping steering to emergency steering and post near emergency controls in the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 5 January 2011
Resolved
Provide approved flexible hose and connections for all fuel lines on the back deck, there is currently about 30' of non-approved hose and crimp connections running from portable fuel tank to three portable generators on back deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 5 January 2011
Resolved
Provide containment around portable diesel fuel tank on back deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2011
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 5 January 2011
Resolved
Provide access plate for sea chest valve in engine room, current access is only thru unbolting deck plate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 5 January 2011
Resolved
Provide Name of vessel and hailing port of stern of vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 January 2011
Resolved
Provide stanchion to support metal chains going across back deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Lifesaving › Lifefloat › Float Free
Issued 5 January 2011
Resolved
Provide proper float free arrangement for lifefloats located on top of bridge. There is significant rigging around mast which could prevent lifefloats from floating free. Also current location makes it very difficult for floats to be deployed manually.
Action required: 705 - Other - as specified
Due 4 April 2011
Resolved 22 March 2012
Resolution: Received notification from company that guide wires above life floats have been removed, company still plans on moving floats and installing liferafts at next drydock.