BAY SPIRIT II
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named BAY SPIRIT II
BAY SPIRIT II is a 2009 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 2008, most recently in March 2026, along with 68 deficiencies, 1 operational control and 5 casualty investigations between 2013 and 2023.
Records from 2008 to 2026. Most recent: inspection, 3 March 2026.
- Built
- 2009
- Last inspected
- 3 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 68 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2013–2023
Identity
1220692
WDL4061
989552
Flag
UNITED STATES
367413230
Maury page id
psix-989552
Inspections, by type
…with no type recorded3
Years with a record
16 calendar years (2008–2026)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)72.0 ft × 26.0 ft × 5.9 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPOON SPRINGS, FL, UNITED STATES · built 2009
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationTwin Hull
Hailing portTAMPA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL4061MMSI 367413230 · active · voluntarily equipped · granted 14 January 2020, expires 14 January 2030
WDE9083MMSI 367413230 · expired · compulsorily equipped · granted 4 June 2009, cancelled 10 August 2019 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 36
3 March 2026
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8311653
11 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8059370
2 October 2024
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7990999
7 December 2023
Deficiency Check · Administrative Inspection · Examination of Repairs · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7836074
19 September 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7795843
7 February 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7616247
29 November 2022
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7601248
3 October 2022
Damage Survey · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7570795
8 September 2022
Internal Structural Exam · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7548589
5 May 2022
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7444385
2 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7403341
22 October 2021
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7337759
19 August 2021
Hull Examination · Deficiency Check · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7291218
14 July 2021
Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7256118
3 December 2020
Examination of Repairs · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7094584
10 February 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6884069
11 October 2019
Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6833268
11 October 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6835521
29 July 2019
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6766079
3 December 2018
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6588132
9 October 2018
Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6554211
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512863
3 July 2018
Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6465229
2 April 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6383188
23 October 2017
Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6293032
11 September 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6242682
15 November 2016
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6041208
16 November 2015
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5764535
10 September 2015
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5718548
28 June 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4905914
28 June 2014
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4907130
30 July 2012
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4395087
9 September 2011
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4140313
22 July 2011
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4090531
23 February 2011
Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3950897
27 August 2008
Deadweight Survey · Hull Examination · Initial Certification · Deficiency Check · Plan Review "T" Boat · Construction Oversight · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3412893
Deficiency record · 68
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 March 2026
Resolved
46 CFR 177.410(c)(4)
Machinery space boundaries: Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant.
MI observed insulation and boundary panels were absent in both the starboard and port engine compartments.
Submit photographs of insulation and boundary panels equipped in the spaces once completed. Due date: 16Mar26
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2026
Resolved
46 CFR 182.720(e)(3)(v)(b)
Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems, subject to the following requirements: Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose, which: (1) Do not rely on the spring tension of the clamp for compressive force; and(2) Are installed beyond the bead or flare or over the serrations of the mating spud, pipe, or hose fitting. MI observed single hose clamp on both port and starboard engines.
Add additional hose clamps.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2026
Resolved
46 CFR 180.70(d)(1)
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. MI observed floating water light containing unapproved alkaline batteries.
Replace with approved battery type.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2025
Resolved
A vessel's hull must not carry current as a conductor. MI observed bilge piping located in void spaces beneath port and starboard bathrooms to have damaged grounding wire.
46CFR183.370(a)
16c
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 February 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all engines that draw intake air from within the protected space. MI observed diesel generators located in the protected spaces that do not shutdown upon activation of the pre-engineered fixed gas fire extinguishing system.
46CFR181.420(a)(4)
16c
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 8 December 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Port side deck around machinery space hatch has areas that are soft when stepped on.
Provide repair proposal to marine inspector.
46 CFR 177.100
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 December 2023
Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter.
One of the three ring life buoy' grab line is breaking down due to UV degradation.
Provide a replacement ring life buoy.
46 CFR 180.70(a)(3)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 December 2023
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection.
Vessel was due for renewal COI inspection on 03DEC23 and has yet to receive a renewal COI inspection.
Vessel shall not operate with passengers until new COI has been issued.
46 CFR 176.100
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 February 2023
Resolved
Each floating waterlight must be approved in accordance with 161.010 in subchapter Q of this chapter.
Battery in the waterlight was of a spring type but modified with a welded bolt.
46 CFR 180.70 (d)(1)
705 (prior to night time operation) C
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2023
Resolved
All metallic enclosures and frames of electrical equipment must be permanently grounded to the hull on a metallic vessel. On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor.
Port side engine room bilge plate and intake fire pump piping has wasted grounding wires.
46 CFR 183.372 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 February 2023
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks.
Port side engine room generator exhaust piping side secured to the frame by plastic zip ties.
46 CFR 182.430 (b)
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 November 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] notification from O/O regarding the vessel's reported damage, MIs observed fwd stbd samson post was displaced from it's mount causing local structural damage to the deck, sewage tank, and railing assembly.
Vessel shall not carry passengers until repair proposal is provided to the local OCMI and the damage is rectified to the satisfaction of the Coast Guard.
46 CFR 176.600(a)
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 3 October 2022
Resolved
The weather deck on a flush deck vessel must be watertight.
MI found the starboard forward and aft cleats pulled up from the deck causing the deck to crack and split, loosing the water tight integrity.
46 CFR 178.410(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 October 2022
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction.
MI found the deck hand rail fabric lines torn from the rail, and unable to support the required forces.
46 CFR 177.900(b)
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 5 May 2022
Resolved
Alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval.
Submit new and old engine specification sheets for both engines to MSC to determine the need for a stability test. Notify local OCMI upon MSC's decision.
46 CFR 176.700(a)
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 March 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
The Port and Starboard generators were missing belt guards. In addition the Starboard generator did not have a guard over the winding coils.
46 CFR 177.960
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts.
The electrical outlet in the port side engine room does not have a cover installed on it.
46 CFR 183.200(c)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 March 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions.
The fireboy in the port side engine compartment has a zip tie attached to the manual discharge cable.
Provide proof of proper installation.
46 CFR 181.420(4)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 March 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent
contents and instructions.
The ammonia inhalants on board were expired.
46 CFR 184.710
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 March 2022
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry at least one rescue boat unless the cognizant OCMI determines that: The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water.
Vessel has a rescue platform with a solid base. The base of the platform should be made to reduce the effect of wave action on the platform.
46 CFR 180.210(a)(1)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 March 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
The starboard fore peak tank has several areas of fiberglass de-lamination occurring.
Submit repair plan for the affected areas.
46 CFR 177.100
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 March 2022
Resolved
On a vessel of more than 65 feet in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge.
The port and starboard fire pumps were leaking at the shaft seal, and were only producing 50 psi at the pump outlet.
46 CFR 181.300(b)
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 March 2022
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable.
Several hose clamps on the flexible hose leading to the fire pump in the starboard side engine room are missing or corroded.
46 CFR 182.410(d)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2021
Resolved
Alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval.
Submit electrical plans for approval to MSC for generator replacement. Notify local OCMI upon reception of approved plans.
46 CFR 176.700(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2021
Resolved
Alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval.
Submit generator specifications sheets to MSC to determine need for additional stability test. Notify local OCMI upon reception of proposal.
46CFR176.700(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 January 2021
Resolved
Nonmetallic hose may be for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable.
Identified nonmetallic engine exhaust hose on both port and starboard engine was found single clamped.
46 CFR 182.430
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 October 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port main engine is overheating.
Make repair to port main engine prior to carriage of passengers to the satisfaction of Coast Guard Marine Inspector. 46 CFR 182.100
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 August 2019
Resolved
Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may require the vessel to effect permanent repairs.
The two aft watertight hatch covers, port and starboard, above each steering gear are no longer watertight. The structural supports of the watertight hatch, below deck, are partially rotted. Submit a repair proposal and repair as original. 46 CFR 176.600(d)
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 August 2019
Resolved
Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may require the vessel to effect permanent repairs.
Number 1 and 2 transverse under-deck beams located in the fore-peak, forward of the collision bulkhead were delaminated from the bottom hull in crawl space in the center of the two hulls of the catamaran. Submit a repair proposal and repair once approved. 46 CFR 176.600(d)
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: Incorrect Name.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 November 2017
Resolved
Replace 2 unserviceable adult size life jacket to the satisfaction of the attending marine inspector. 46CFR180.71
Fire Fighting › Fire Main › Pressure
Issued 13 November 2017
Resolved
Found port side fire pump gauge non operable, replace gauge to satisfaction of attending marine inspector. 46CFR181.300
Construction/Loadline › Hull › Bottom Plating
Issued 13 November 2017
Resolved
Found aft stbd internal hull FRP cracked, repair to the satisfaction of the attending marine inspector. PROVIDE REPAIR PROPOSSAL PRIOR TO CARRYING PASSNGERS. 46CFR176.610
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 November 2017
Resolved
Found waterlight battery not approved type, replace with approved type to the satisfaction of the attending marine inspector. RESTRICTED TO DAY TIME OPS ONLY. 46CFR180.70
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 November 2017
Resolved
Found missing seating for 18 passangers, replace seating upper deck port side to the satisfaction of attending marine inspector. 46CFR177.800 REDUCE PASSANGER COUNT TO 131.
Construction/Loadline › Penetrations › Bottom Plug
Issued 13 November 2017
Resolved
Found plastic cap on stbd side through hull fitting, replace with metal cap to the satisfaction of the attending marine inspector. 46CFR176.610
Communications › Radio Communications › VHF Radiotelephone
Issued 13 November 2017
Resolved
Found FCC Station Lic not posted and MMSI# not entered into VHF-FM radio, provide prove to attending marine inspector. 47CFR80
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 28 November 2016
Resolved
Retain FCC Bridge-to-Bridge Certificate and Marine Radio Safety Telephony Certificate onboard and restrict operation to 1000 ft from shore iaw 47 CFR 80.13.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 15 November 2016
Resolved
Turbocharger outlet requires insulation. Insulate all surfaces in whicn temperatures exceed 150 degrees Fahrenheit iaw 46 CFR 177.970.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 November 2016
Resolved
Properly cap off or remove dead end wiring iaw 46 CFR 183.340.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 November 2016
Resolved
Replace clamp on sea water cooling for generator set where wasted iaw 46 CFR 176.800(a).
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 November 2015
Resolved
Ensure renewal of FCC safety certificate. Vessel is restricted to 1000 ft from shore until deficiency is corrected to satisfaction of Marine Inspector IAW 47 CFR 80.401.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 17 November 2015
Resolved
Ensure renewal of FCC Bridge to Bridge certificate IAW 47 CFR 80.409
Engineering › Sea-water System (primary cooling) › Valve
Issued 10 September 2015
Resolved
Prove proper operation of port MDE sea valve IAW 46 CFR 176.802.
Construction/Loadline › Hull › Hull Plating
Issued 10 September 2015
Resolved
Properly repair damaged areas (blisters), identified durign hull exam IAW 46 CFR 176.802.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 10 September 2015
Resolved
Properly repair fiberglass (delamination), located in port and Stbd foward peak voids IAW 46 CFR 176.802.
Stability › Intact Righting Energy › General
Issued 10 September 2015
Resolved
Provide statement of work for engine change out, including all engine specs (old & new). Properly calculate any changes of vessel's lightship characteristics to MSC for review/approval IAW 46 CFR 170.15.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 30 July 2012
Resolved
Provide permanent electrical insulation for port A/C circulation pump and update electrical 1-line diagram including list of consumers IAW 46CFR183.210.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 July 2012
Resolved
Missing mounting brackets for 2-BII portable CO2 stored in AFT electrical room. Install CO2 mounting brackets IAW 46CFR181.520.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 July 2012
Resolved
Found water collected in AFT & FWD adult LJ storage. Fabricate storage drainage IAW 46CFR180.78
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 July 2012
Resolved
In operable all round anchor light. Repair and show proper light operation IAW 46CFR183.420.
Fire Fighting › Fire Pumps › Pressure
Issued 30 July 2012
Resolved
Port fire pump pressure gauge does not reach 60 PSI. Show that pump can sustain 60 PSI on pressure gauge IAW 46CFR181.300.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 25 July 2011
Resolved
FIXED GAS SYSTEM NOT ANNUALLY SERVICED. FIXED GAS SYSTEM IS REQUIRED TO HAVE ANNUAL INSPECTIONS AND TESTS AS PER 46 CFR 176.810(B)(2). VESSEL IS RESTRICTED IN THE CARRIAGE OF PASSENGERS UNTIL ANNUAL SERVICING CERTIFICATE IS PROVIDED.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 27 August 2008
Resolved
Replace fire-boy pre-engineered fire extinguishing system for the starboard engine compartment; in the interim, the vessel is permitted to operate utilizing an extra B-II portable fire extinguisher outside the space in addition to a live fire watch.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 August 2008
Resolved
Make proper adjustment to the remote pull cable for the pre-engineered fire extinguishing system.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 27 August 2008
Resolved
Replace battery for forward ceiling smoke detector between the vessel's bathrooms.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 August 2008
Resolved
Replace battery for ring buoy light.
Engineering › Steering Gear System › Ram
Issued 27 August 2008
Resolved
Prior to operation, repair the vessel's starboard hydraulic steering ram.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 27 August 2008
Resolved
Permanently affix warmer oven in way of the starboard aft utility compartment passageway and ensure proper clearance to the exit door.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 August 2008
Resolved
Provide written instructions for the proper operation of the vessel's installed bilge system and affixed in the location of bilge operation station.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 August 2008
Resolved
Ensure that all open circuits in the switchboards are covered with a blank covering.
Engineering › Steering Gear System › Hydraulic Hose
Issued 27 August 2008
Resolved
Determine cause of hydraulic fluid leak to the vessel's steering wheel fill cap on the bridge.
Documentation › Markings/Placards › Capacity Marking
Issued 27 August 2008
Resolved
Ensure all markings for life-saving, fire fighting equipment, and other required markings are displayed in accordance to applicable regulations and IMO Resolution A.760(18).
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 27 August 2008
Resolved
Replace the vessel's anchor with a type rated for the size of the vessel.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 27 August 2008
Resolved
Ensure all seating onboard are permanently affixed to the deck.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 27 August 2008
Resolved
Provide to CG a copy of the vessel's machinery/electrical plans.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 27 August 2008
Resolved
Provide to CG a copy of the vessel's revision 2 plans; in particular, drawings 3 and 10 showing the changes of the doors in way of the vessel's aft utility room and forward access.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 27 August 2008
Resolved
Provide to CG a copy of the fire and safety arrangement plan indicating the locations of the vessel's fire and life-saving appliances.
Casualty record · 5
16 April 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4612027
28 June 2014Routine · role: Involved in a Marine Casualty · activity 4905914
30 June 2018Routine · role: Involved in a Marine Casualty · activity 6474612
11 October 2019Routine · role: Involved in a Marine Casualty · activity 6835521
19 September 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7795843
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.