MAURY USCG vessel records Sign in
← All vessels

AS FABIANA

AS FABIANA is a 2007 freight ship. The Coast Guard has recorded 30 inspections since 2008, most recently in April 2020, along with 14 deficiencies and 10 operational controls.

Records from 2008 to 2020. Most recent: inspection, 7 April 2020.

Built
2007
Last inspected
7 April 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9395109 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
989729
Flag
PORTUGAL
—
Maury page id
psix-989729

Inspections, by type

…with no type recorded10
Years with a record 9 calendar years (2008–2020)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it15375 - Convention (Subpart B), Gross Ton
5983 - Convention (Subpart B), Net Ton
25324 - Displacement, Ton
18480 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

7 April 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6934514
27 March 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6648529
15 February 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6626528
8 February 2019 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6622232
18 January 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6612349
13 January 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6609660
13 December 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6597113
19 November 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6583187
17 October 2018 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6563535
7 September 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6534754
2 August 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6498978
5 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6467332
22 June 2018 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6451108
15 June 2018 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6445030
31 May 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6429871
30 May 2018 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6428863
18 May 2018 COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6416826
9 March 2018 Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6364978
4 January 2018 ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6332611
10 October 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6284363
6 April 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6121879
5 March 2017 ISPS II Exam · Ballast Water Examination · Administrative Inspection · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6098539
5 March 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6099142
14 August 2015 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5215568
29 July 2015 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5199968
9 May 2012 ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4306938
14 December 2011 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4206594
30 November 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3899321
17 November 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3365133
11 November 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3360118

Deficiency record · 14

Navigation › Collision/Grounding Avoidance › Radar
Issued 15 June 2018 Resolved
M/V AS FABIANA reported inoperable Second Marine Band Radar. Radar's display screen is not functioning properly although it is able to be viewed with Primary Radar's screen.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2018
Resolved 5 July 2018
Resolution: MSU Savannah received technicians report attesting to repairs
Lifesaving › Rescue Boat › Propulsion Engine
Issued 5 March 2017 Resolved
0615-Life saving appliance-All life saving appliances shall be in working order and ready for immediate use. Vessels rescue boat does not start. 74 Solas 14 cons. ChIII Reg 20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2017
Resolved 5 March 2017
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 5 March 2017 Resolved
1799-Each transfer pipe system must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. Documentation of test missing. 33 CFR 156.170(d)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 6 April 2017
Resolution: Vessel provided documentation attesting to proper testing of the transfer pipe.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 5 March 2017 Resolved
1799-Marine pollution-Each person in charge must have in his or her position a copy of the vessel transfer procedures as appropriate. Vessel could not procedure transfer procedures.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 5 April 2017
Resolved 6 April 2017
Resolution: Vessel provided transfer procedures.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 March 2017 Resolved
0899-Accident prevention-Hazardous ships stores must be stowed in suitable racks. Oxygen and acetylene cylinders not stowed properly. 46 CFR 147.60 (b)(i)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 6 April 2017
Resolution: Vessel removed empty gas cylinders from the deck and added addtional storage rack for filled bottles.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 9 May 2012 Resolved
2560-THE COMPANY SHALL ENSURE THAT THE SMS POLICY IS IMPLEMENTED AND MAINTAINED AT ALL LEVELS AND IN ADDITION. PERIODICALLY EVALUATE THE EFFICIENCY OF AND WHEN NEEDED REVIEW THE SMS. AN EXTERNAL AUDIT OF SHIPS SECURITY/SMS PROCEDURES IS REQUIRED AS PER CAPTAIN OF THE PORT ORDER NUMBER 4306938. 74SOLAS09 CONS CH IX REG 3.1/ISM CODE PART A 2.2 AND 12.2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2012
Resolution: Received report from class.
Fire Fighting › Fire Hoses › Connections
Issued 14 December 2011 Resolved
072- Firefighting equipment Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire plug by ACR space has device connected to it that prevents the immediate use of nearby fire hose.
Action required: 705 - Other - as specified
Due 14 December 2011
Resolved 14 December 2011
Resolution: Crew removed device from fire plug in presence of PSC examiner.
Fire Fighting › Fire Hoses › Condition
Issued 14 December 2011 Resolved
0725- Fixed fire extinguishing installation. Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Several fire hoses are housed in protective casings in various states of disrepair, many do not close as intended resulting exposure fire hoses and nozzles to the elements.
Due 14 January 2012
Resolved 28 January 2012
Resolution: Repairs were made and approved by classs.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 December 2011 Resolved
0710- Fire prevention. The following fire protection system shall be kept in good working order so as to ensure their required performance if a fire occures.Structural fire protection including fire resistant divisions. Entrance to the emergency generator space has an A15 fire door with a faulty locking mechanism that prevents the door from fully closing.
Action required: 705 - Other - as specified
Due 14 December 2011
Resolved 14 December 2011
Resolution: Ship’s crew repaired the door prior to completion of exam.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 30 November 2010 Resolved
Vessel improperly installed a battery charger in the Emergency Generator space without Class approval.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2010
Resolution: Vessel unwired and removed the battery charger from service.
Engineering › Steam System (main) › Piping
Issued 30 November 2010 Resolved
Multiple steam leaks were found on piping flanges throughout the engine room
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 7 December 2010
Resolution: Condition of Class, the deficiency is authorized to be repaired at next dry dock.
Engineering › Lubricating Oil Service System › Tube
Issued 30 November 2010 Resolved
Multiple self closing devises on sounding tubes in engine room do not operate properly.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 December 2010
Resolved 7 December 2010
Resolution: Condition of Class, the deficiency is authorized to be repaired at next dry dock.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 17 November 2008 Resolved
Vessel's Non-Tank Vessel Response Plan does not reflect name change. Therefore, the plan on board needs to be submitted and reviewed by National Vessel Response Center with new vessel name change.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 November 2008
Resolution: Received e-mail from Vessel Response Plan issuing authority ([name withheld]) attesting that VLIET TRADER has had the necessary revision of the plan and the safety of the vessel''s transit plan has not been compromised due to name change.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 November 2008 Resolved
Vessel does not have a certified chief engineer for the new flag state (The Netherlands). Provide written verification from the Flag Administration to the USCG.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2008
Resolution: Rcvd approval letter from Dutch flag state recognizing the chief engineer''s Ukrainian license.

Ownership record