MAURY USCG vessel records Sign in
← All vessels

SERENA M

SERENA M is a tank ship. The Coast Guard has recorded 7 inspections since 2010, most recently in September 2021, along with 6 deficiencies and 1 operational control.

Records from 2010 to 2021. Most recent: inspection, 14 September 2021.

Built
Not recorded
Last inspected
14 September 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9444508 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V8875
989747
Flag
SINGAPORE
—
Maury page id
psix-989747

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2010–2021)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25432 - Convention (Subpart B), Gross Ton
9897 - Convention (Subpart B), Net Ton
49010 - Displacement, Ton
39710 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

14 September 2021 PSC B · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7312250
24 March 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4822089
2 March 2014 COC-CHEM Renew · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4808538
2 August 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4099204
2 August 2011 ISPS I Exam · COE-Offshore
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4102478
23 December 2010 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3915315
17 December 2010 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3912376

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 14 September 2021 Resolved
74SOLAS(2020)I/11(a)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respsects shall remain fit to proceed to sea without without danger to the ship or persons onboard. Observed pressure vacuum breaker sightglass gasket leaking glycol and water, sight glass mixture level not visible.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 30 September 2021
Resolution: Vessel and class provided proof of replaced gasket in the P/V Breaker and issues regarding low water level.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 2 March 2014 Resolved
2199 - Incinerator shall be designed and approved by the Administration. Primary Flam Eye combustion chamber failure alarm inoperable, not allowing for safety shutdown. If unable to fix alarm, vessel shall arrange for sludge offload prior to departure. MARPOL 73/78 Annex VI/16.
Action required: 705 - Other - as specified
Due 6 April 2014
Resolved 24 March 2014
Resolution: Received ABS Class report attesting to the satisfactory operation of the ship incinerator.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 March 2014 Resolved
1730 - Oil filtering equipment shall be designed and approved by Administration to ensure any oily mixture discharge into the sea after passing through system shall not exceed 15ppm. Oily water separator is shutting down due to system malfunction. Bilge water holding tank increases to 18m3, vessel is to offload bilge water shore. MARPOL 73/78 Annex I/14.6
Action required: 705 - Other - as specified
Due 6 April 2014
Resolved 24 March 2014
Resolution: Received ABS Class report attesting to the satisfactory operation of the ship Oily Water Separator.
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 2 March 2014 Resolved
0199 - Vapor Control System shall be approved by Administration. vessel does not have approved Vapor Control Letter from current Class Society. Class Society shall approve Vapor Control system and provide Vapor Control Letter prior to loading within US waters. 46 CFR 39.1013
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2014
Resolution: Received ABS statement of fact as well as transfer of class documentation attesting to the vessel being fitted with a vapor control system that is in accordance with the applicable requirements of ABS rules. ABS will not reissue the BV approval letter.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 17 December 2010 Resolved
The vessels IGS is required to have an audible and visual alarm for high gas pressure. The pressure transmitter is currently inoperable, making the system unable to alarm if the IGS pressure is too high. Vsl cannot load or discharge cargo that requires the use of inert gas in the US until proper operation of this alarm is proven. Correct to the satisfaction of class. SOLAS 09 CONS. II-2/4.5.5.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 December 2010
Resolution: Received class report attesting to proper repairs.
Deck/Cargo › Cargo Stowage › General
Issued 17 December 2010 Resolved
Cargo samples shall be stowed in space cell divided in order to avoid shifting of bottles at sea. Cargo samples are currently stowed in plastic bags on shelf next to designated cargo sample stowage space. The designated space is currently being used as storage for tools and other miscellaneous items. Correct to the satisfaction of the Administration. SOLAS 09 CONS. VII/10.1 IBC CODE 16.5.2.1
Action required: 705 - Other - as specified
Due 31 December 2010
Resolved 30 December 2010
Resolution: Received class report attesting to proper repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.