MAURY USCG vessel records
← All vessels

BREEZE

BREEZE is a 2008 freight ship. The Coast Guard has recorded 64 inspections since 2016, most recently in July 2026, along with 9 deficiencies and 9 operational controls.

Records from 2016 to 2026. Most recent: inspection, 22 July 2026.

Built
2008
Last inspected
22 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 July 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9389423
989795
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-989795

Documentation record

Tonnage as PSIX records it8246 - Convention (Subpart B), Gross Ton
11163 - Dead Weight, Metric Ton
15455 - Displacement, Metric Ton
4002 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 64

22 July 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8447795
3 May 2026 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8358221
1 April 2026 PSC B · ISPS Exam · COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8338904
26 September 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8239867
23 September 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8239811
19 September 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8235073
15 September 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8235047
31 July 2025 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8199109
5 March 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8087374
18 February 2025 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8081072
10 December 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8045865
24 October 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8022229
20 June 2024 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7936718
17 June 2024 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7937134
13 June 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7933652
15 May 2024 Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 7912773
1 May 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7902658
27 March 2024 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7885403
26 March 2024 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7885169
9 November 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7820297
12 September 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7790413
26 July 2023 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7749751
19 July 2023 PSC B · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7743918
17 July 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7745045
29 October 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7585827
17 July 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7509536
12 January 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7378418
10 January 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7377465
5 January 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374621
3 January 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374957
29 December 2021 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7373641
29 June 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7237069
16 June 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7226132
17 March 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7155809
25 January 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7130457
26 October 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7084435
10 August 2020 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7027766
6 August 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7023356
29 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7016392
22 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7011210
20 July 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7011512
12 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7003996
12 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7004002
8 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6996413
8 July 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7000689
29 June 2020 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6990906
14 June 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6973325
24 May 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6959072
7 April 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6936491
29 March 2020 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6932905
17 February 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6910281
27 January 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6897366
22 January 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7037147
13 November 2019 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6852920
17 October 2019 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6836278
16 October 2019 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6834156
28 August 2019 Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6793635
26 August 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6795120
4 March 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6635957
14 January 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6609861
17 October 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6560875
18 October 2017 Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6289942
6 June 2017 Administrative Inspection · NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6167673
17 October 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6023598

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2026 Resolved
Ships shall be designed, constructed and Maintained in compliance with structural, mechanical and electrical requirements of a classification society. PSCO observed severe wastage on numerous cargo hold cleat brackets. 74 SOLAS (04) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2026
Resolution: PSCO verified class report and attested to full repair of cargo hold cleat brackets.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 September 2025 Resolved
WHERE A FIXED GAS FIRE-FIGHTING SYSTEM IS USED, OPENINGS WHICH MAY ADMIT AIR TO, OR ALLOW GAS TO ESCAPE FROM, A PROTECTED SPACE SHALL BE CAPABLE OF BEING CLOSED FROM OUTSIDE THE PROTECTED SPACE. PSCO OBSERVED MISSING FIRE CAPS FOR CARGO HOLD CHANNEL DRAIN VALVE. 74SOLAS(04) II-2/10.4.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 September 2025
Resolved 26 September 2025
Resolution: Received master statement and class report attesting to the repair. Deficinecy rectified.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 18 February 2025 Resolved
CARGO SHIPS 500 GROSS TONS AND ABOVE ON AN INTERNATIONAL VOYAGE SHALL BE FITTED WITH AN AIS ; VESSEL'S AIS IS NOT RECEIVING INFORMATION AS REQUIRED BY REGULATION V/19.2.4.5.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 20 February 2025
Resolved 19 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 July 2023 Resolved
Recovery time of the rescue boat shall not be more than five minutes. PSCO observed recovery time in excess of 20 minutes, due to rescue boat davit only being operational in manual mode. 74SOLAS920140 III/17.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2023
Resolved 27 July 2023
Resolution: Received class report attesting to repair.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 19 July 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed slewing davit not operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2023
Resolved 19 July 2023
Resolution: Reviewed DNV class report that included photos of the repair by an authorized service prividor as well as class attesting to witnessing the 1.1x load test and issuing a full term CSSEC. Report attached in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed 02 lifejackets in way of 6-man liferaft were missing light.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 19 July 2023
Resolved 19 July 2023
Resolution: Chief Mate replaced lights on both lifejackets and demonstrated functional condition.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 October 2019 Resolved
1730 - Oily Water Separating Equipment Except as specified in paragraph 3 of this regulation, any ship of 400 gross tonnage and above but less than 10,000 gross tonnage shall be fitted with oil filtering equipment complying with paragraph 6 of this regulation. Any such ship which may discharge into the sea ballast water retained in oil fuel tanks in accordance with regulation 16.2 shall comply with paragraph 2 of this regulation. PSCO found the 3 way valve for discharge to be stuck in the closed position. MARPOL ANNEX I REG 14.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 13 November 2019
Resolution: Attneded the vessel to verify 3-way vavle replacement and operation. Test sat. Also recieved class report from DNV-GL attesting to repair.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 18 October 2017 Resolved
Where emergency source of electrical power is a generator, it shall be capable of being automatically started and supply required load as quickly and safely as possible. The #1 battery bank for emergency generator is inoperable. 74 SOLAS(04 Conv.) CHII-I/ Reg 43.3.1.3. Action 17AC
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2017
Resolved 18 October 2017
Resolution: Battery set #1 for emergency generator was replaced with a new set of batteries. DNVGL and Coast Guard attended the vessel and witnessed proper operation of the emergency generator with no further issues present at the time of exam. See DNV/GL survey doc.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 June 2017 Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights complying with the requirements of paragraph 2.1.2 of the code. More than half of the lifebuoys self-igniting lights did not ignite. 74 SOLAS (14 Cons.)Ch.III/7.1.3. Action taken 10C
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Vessel replaced batteries to all self-igniting lights for the lifebuoys lights that were not self-igniting. Verified they worked after battery replacement with no further discrepancy at the time of exam.