MAURY USCG vessel records Sign in
← All vessels

STAR KESTREL

STAR KESTREL is a 2008 tank ship. The Coast Guard has recorded 23 inspections since 2008, most recently in April 2025, along with 10 deficiencies and 2 operational controls.

Records from 2008 to 2025. Most recent: inspection, 29 April 2025.

Built
2008
Last inspected
29 April 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9321940 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
989833
Flag
PANAMA
—
Maury page id
psix-989833

Inspections, by type

…with no type recorded3
Years with a record 14 calendar years (2008–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30081 - Convention (Subpart B), Gross Ton
13648 - Convention (Subpart B), Net Ton
51228 - Dead Weight, Metric Ton
60033 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

29 April 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8115262
7 November 2024 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8024953
12 April 2024 COC-CHEM & TVE Renew · PSC B · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7894294
7 November 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7590416
29 September 2021 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7322606
28 September 2020 MARPOL Annex VI Survey · PSC B · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7066618
15 October 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6834724
20 May 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6686542
18 May 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6686961
17 May 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6686648
4 February 2019 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6619730
27 January 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6615667
10 May 2018 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6406342
13 February 2018 MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6354649
8 May 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6141645
1 December 2015 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5770814
13 October 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5001510
24 December 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4213971
23 December 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4213471
19 November 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3894684
11 November 2010 COC-CHEM Renew · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3889308
4 December 2009 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3643311
28 November 2008 MARPOL Annex I Examination · COC-TVE Renew · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3366885

Deficiency record · 10

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 April 2024 Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances. During operational test of STBD lifeboat, PSCO witnessed propeller hitting propeller guard when operating in forward and astern propulsion. 74SOLAS(20) III/20.3.3.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2024
Resolution: Vessel completed repairs to lifeboat steering system to the satisfaction of attending LR surveyor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 14 April 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements. During documents check, PSCO observed entries on 11APR24 and 12APR24 for non-comminuted category B (food waste) into an ANNEX V special area. The vessel has a comminuter on board and various crew members provided different answers for when the comminuter is used and when it was last used. Additionally, the crew indicated that both entries were clerical errors and that they are so accustomed to not using the comminuter they accidently recorded those entries as such. Recommend an internal audit focusing on garbage management plan within 30 days. 74SOLAS(20) IX/3.1 ISM 10.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 May 2024
Resolution: Company completed internal audit on 28APR2024. Identified 5 areas of improvement including MARPOL Annex V, maintenance of life boats, hazard identification, electric safety in hazardous areas, and maintenance of the deck. Crew conducted training on topics
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2024 Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO observed severe wastage on electrical cable runs on deck located within the hazardous area per the vessel's approved hazardous location plan. PSCO observed large holes in cable runs to starboard slop framo flow meter, 6S framo flow meter, 5S tank radar, and 2S electrical junction box. 74SOLAS(20) VII/10 IBC Code 10.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2024
Resolution: Crew replaced electrical conduit on deck in kind to satisfaction of LR.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 14 April 2024 Resolved
Discharge of the following garbage into the sea within special areas shall only be permitted while the ship is en route and as follows: .1 Discharge into the sea of food wastes as far as practicable from the nearest land, but not less than 12 nautical miles from the nearest land or the nearest ice shelf. Food wastes shall be comminuted or ground and shall be capable of passing through a screen with openings no greater than 25 mm. PSCO observed entries in vessel's garbage record book for non-communited category B (food waste) into the Gulf of Mexico, an ANNEX V special area. The vessel has a communiter on board and explained that it was a clerical error. MARPOL Annex V 6.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 April 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed holes in sample port on forepeak watertight hatch. 74SOLAS(20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 May 2024
Resolution: Crew repaced sample port on forepeak watertight hatch in kind.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed starboard side MGO line pressure guage broken and holes in 1P ballast tank flame screen. 74SOLAS(20) I/11
Action required: 10 - Deficiency Rectified
Resolved 14 April 2024
Construction/Loadline › Markings › Load Line Mark
Issued 8 May 2017 Resolved
ICLL CHAP 1 / REG 8 – THE RINGS, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THEY SHALL ALSO BE PERMINENTLY MARKED ON THE SIDES OF THE SHIP TO THE SATISFACTION O THE ADMINISTRATION. THE MARKS SHALL BE PLAINLY VISIBLE, AND, IF NECCESARY, SPECIAL ARRANGEMENTS SHALL BE MADE FOR THIS PURPOSE. VESSEL LOAD LINES ARE NOT PROPERLY OR PERMANENTLY A
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2017
Resolution: see attached class report
Communications › Radio Communications › EPIRB
Issued 8 May 2017 Resolved
74 SOLAS (14) IV/ 7.1.6.4 – EVERY SHIP SHALL BE PROVIDED WITH A SATELLITE EMERGENCY POSITIVE-INDICATING RADIO BEACON (EPIRB) WHICH SHALL BE CAPABLE OF FLOATING FREE IF THE SHIP SINKS AND OF BEING AUTOMATICALLY ACTIVATED WHEN AFLOAT. VESSEL OPERATED WITHOUT EPIRB HYDROSTATIC RELEASE FOR 5 DAYS. CREW SECURED EPIRB IN CRADLE WITH STRAPS AND ZIPTIES, PREVENTING EPIRB FROM FLOATING FREE.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2017
Resolution: see attached class report
Fire Fighting › Fixed Deck Foam System › Monitors
Issued 8 May 2017 Resolved
74 SOLAS (04) II-2 / 14/2/1/2 – FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER. PORT SIDE FIRE MONITOR NEAR HOUSE IS LEAKING EXCESSIVELY UPON USE.
Action required: 705 - Other - as specified
Due 21 May 2017
Resolved 9 May 2017
Resolution: see attached class report
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 11 November 2010 Resolved
Vessels SMS maintenance program requires PV valves to be bench tested annually. Test equipment used in this process is to be calibrated annually at a shore facility. Test equipment was last serviced AUG 2009
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 19 November 2010
Resolution: Recieved receipt of calibrated test equipment on board vessel

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.