BBC CHALLENGER is a 2008 public freight. The Coast Guard has recorded 25 inspections since 2008, most recently in April 2026, along with 8 deficiencies — 1 with no resolution recorded — and 8 operational controls, 2 with no removal date recorded.

Records from 2008 to 2026. Most recent: inspection, 13 April 2026.

Built
2008
Last inspected
13 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

9369095 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
990003
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-990003

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 13 calendar years (2008–2026)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7878 - Convention (Subpart B), Gross Ton
15101 - Displacement, Metric Ton
11121 - Dead Weight, Metric Ton
3909 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

13 April 2026 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8347231
15 October 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8253157
19 April 2025 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8115319
20 February 2025 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8082095
11 February 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8072868
6 August 2024 PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7972523
14 March 2023 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7647531
23 July 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7514977
19 June 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7229380
13 March 2019 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6641682
11 March 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6639266
27 February 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6633547
26 August 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6521673
4 May 2018 COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6403134
28 April 2018 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6406014
5 July 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6185921
3 July 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6195667
28 September 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4153054
24 September 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4153091
14 January 2010 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3664004
11 December 2009 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3648564
30 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3550597
29 March 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3442534
27 March 2009 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3439909
12 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3361920

Deficiency record · 8

10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 20 February 2025 No resolution recorded
All ships of 300 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.2, be fitted with a speed and distance measuring device, or other means, to indicate speed and distance through the water. Vessel's speed log is inoperable. SOLAS(20) V/19.2.3.4
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 February 2025 — due date passed with no resolution recorded
Resolution: Replacement of transducer for speed log will be done next drydock, June 2026. Flag letter states ship may sail with inoperable speed log following adhering to certain provisions.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 March 2019 Resolved
ICLL (88 Prot.) Reg. 25(2) ICLL (88 Prot.) Reg. 25(3) Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. The openings below the lowest course of the guard rails shall not exceed 230mm. The other courses shall not be more than 380mm apart. While conducting the deck walk, PSCO discovered two missing bottom guard rails, at frames #45 port side and frame #130 starboard. Additionally PSCO discovered 03 damaged guard rails at frame #76 bottom rail port side, frame #74 middle rail port side, and frame #61 bottom rail starboard side.
Action required: 15 - Rectify deficiencies by next port
Due 11 March 2019
Resolved 23 March 2019
Resolution: Crew members repaired bottom guard rails.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 August 2018 Resolved
07108 - Ready availability of fire fighting equipment - Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed a cap covering the hyper-mist nozzle above the boiler. Upon removal of the cap, PSCO observed water dripping from the nozzle. SOLAS 74 (2009 Cons.) II-2/14.1.1; 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2018
Resolved 28 August 2018
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 26 August 2018 Resolved
14107 - Oil discharge monitoring and control system - Oil filtering equipment shall be of a design approved by the Administration. Per MEPC. 107(49), ship staff training shall include familiarization in the operation and maintenance of the equipment. PSCO observed that C/E was unable to demonstrate ability to recall OCM history for overboard discharge. MARPOL I/14.6; MEPC.107(49); 50a.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2018
Resolved 28 August 2018
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2018 Resolved
99101 - Other (Safety in general) - No person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel operator, as appropriate, tests and inspects in accordance with the paragraph. C/E could not produce annual bunker line test records. Rectify deficiency prior to bunker operations in the United States. 33 CFR 156.170; 15c
Action required: 703 - Prior to bunkering operations
Due 26 September 2018
Resolved 28 August 2018
Resolution: PSC NOLA received proper documentation satisfying the requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 December 2009 Resolved
Vessel has an inoperable 9ghz radar. Solas 2004 Cons. Ed. Ch. V, Reg. 19.2.3.2
Action required: 705 - Other - as specified
Due 16 January 2010
Resolved 14 January 2010
Resolution: Received service report from Class stating that a new turning unit was mounted and connected. Radar was switched on and tested. Radar was tested in good working condition.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 July 2009 Resolved
Vessel has oily water separator IAW MEPC.107(49). However, crew did not know how to display history log (date, time, alarm status, operating status). PSC Inspectors had to review the ops manual to retrieve partial inforamtion. MARPOL Annex I, Reg. 14/7 (MEPC.107(49))
Due 30 July 2009
Resolved 30 July 2009
Resolution: Chief Engineer will continue to train and familiarize himself with the OWS using the ops manual provided.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 March 2009 Resolved
15 ppm sensor gave an error message on each attempted test. Troubleshooting section of unit's ops manual suggested cleaning the sensor eye or replacing the sensor eye entirely. Cleaning did not rectify the problem, technician will attend unit at earliest opportunity. MSU Port Arthur will clear deficiency upon receipt of repair/testing report.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 30 July 2009