MAURY USCG vessel records
← All vessels

FSL OSAKA

FSL OSAKA is a 2007 tank ship. The Coast Guard has recorded 8 inspections since 2016, most recently in December 2018, along with 2 deficiencies and 1 operational control.

Records from 2016 to 2018. Most recent: inspection, 18 December 2018.

Built
2007
Last inspected
18 December 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 December 2018
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9354519
9V3815
990234
Flag
SINGAPORE
Maury page id
psix-990234

Documentation record

Tonnage as PSIX records it28063 - Convention (Subpart B), Gross Ton
11804 - Convention (Subpart B), Net Ton
55185 - Displacement, Metric Ton
45998 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

18 December 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6599434
4 December 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6587730
4 August 2018 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6500338
6 January 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6330831
26 September 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6275114
2 March 2017 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6098061
23 February 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6093720
29 October 2016 ISPS II Exam · COC-TVE Renew · COE-Offshore · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6031232

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 December 2018 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers, unless the equipment is appropriate for the space concerned. PSCOs observed that explosion-proof light in cargo pump room (2nd deck, 2nd light from stairwell) has multiple large cracks in housing, compromising the integrity of the fixture. 74SOLAS(04)II-1/45.10
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2018
Resolved 18 December 2018
Resolution: Received proper documentation from Operator attesting to satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 4 December 2018 Resolved
Suitable means shall be provided for the zero and span calibration of fixed gas concentration instruments referred to in paragraph 2.4.2.1 [O2 content of inert gas in IG supply on discharge side of blowers]. PSCOs observed that while O2 content of supplied span gas for IG content meter calibration was 0.5% O2 content, the system was set to read 0.0% O2 content. 74SOLAS(04)II-2/4.5.5.3.2 Ref: 2007 FSS/15.2.4.2.5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2019
Resolved 18 December 2018
Resolution: Received proper documentation from Operator attesting to satisfactory replacement of span gas bottle.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.