Records from 2016 to 2026. Most recent: inspection, 23 July 2026.
Inspection history · 19
23 July 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8444861
22 July 2026
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8439541
10 January 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8059141
6 January 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8058637
24 July 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7965845
8 July 2024
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7952780
2 June 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7924996
1 December 2023
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7828001
13 February 2023
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7631582
8 July 2021
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7249069
8 January 2020
ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6884900
5 February 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6619204
13 August 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6510730
7 July 2018
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6470154
9 February 2018
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6352641
25 January 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6343526
15 January 2017
ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6068679
12 December 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6056614
1 December 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6050932
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 January 2025
Resolved
A second source of energy shall be provided for an additional three starts within 30 minutes unless manual starting can be demonstrated to be effective. PSCO's were informed that the hydraulic start for the emergency generator was inoperable, rendering the emergency generator one means of starting.
74SOLAS(09)II-1/44.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2025
Resolution: Vessel submitted class survey report attesting to the complete operation of the system. In documents tab.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 July 2018
Resolved
2050: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported leaking hydraulic oil resulting from a wasted plug on the spreader winch located on the stern ramp. 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 July 2018
Resolved 7 July 2018
Resolution: PSCO observed that there were no further leaks after a the plug was replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 January 2018
Resolved
MEASURES SHALL BE TAKEN TO THE SATISFACTTION OF THE ADMINISTRATION TO ENSURE THAT THE EQUIPMENT IS FUNCTIONING IN A RELIABLE MANNER AND THAT SATISFACTORY ARRANGEMENTS ARE MADE FOR REGULAR INSPECTIONS AND ROUTINE RESTS TO ENSURE CONTINUOUS RELIABLE OPERATION. ALARM ON LOW PRESSURE CO2 SYSTEM INDICATING LOW LEVEL IN TANK IS SOUNDING CONTINUOUSLY DUE TO UNKNOWN FACTORS, NOT ENSURING CONTINUOUS RELIABLE OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2018
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 January 2018
Resolved
WHERE SOUNDING PIPES ARE USED, THEY SHALL NOT TERMINATE IN ANY SPACE WHERE THE RISK OF IGNITION OF SPILLAGE FROM THE SOUNDING PIP MIGHT ARISE. AS A GENERAL RULE, THEY SHALL NOT TERMINATE IN MACHINERY SPACES. HOWEVER, WHERE THE ADMINISTRATION CONSIDERS THAT THESE REQUIREMENTS ARE IMPRACTICABLE, IT MAY PERMIT THE TERMINATION OF SOUNDING PIPES IN MACHINERY SPACES ON CONDITION THAT ALL OF THE FOLLOWING REQUIREMENTS ARE MET: AN OIL-LEVEL GUAGE IS PROVIDED MEETING THE REQUIREMENTS OF PARAGRAPH 2.2.3.5.2: OTHER OIL-LEVEL GAUGES MAY BE USED IN PLACE OF SOUNDING PIPES SUBJECT TO THE FOLLOWING CONDITIONS: IN CARGO SHIPS, THE FAILURE OF SUCH GAUGES OR OVERFILLING OF THE TANK SHALL NOT PERMIT THE RELASE OF FUEL INTO THE SPACE. THE ADMINISTRATION MAY PERMIT THE USE OF OIL LEVEL GUAGES WITH FLAT GLASSES AND SELF CLOSING VALVES BETWEEN THE GUAGES AND FUEL TANKS. SELF CLOSING VALVES WERE MECHANICALLY HELD OPEN ON FUEL OIL TANKS THROUGHOUT ENGINE ROOM. CREW REMOVED MECHANICAL HOLD BACK DEVICES. 74SOLAS(14)II-2/4.2.2.3.5.1 10(c)
Condition: Placed in Improper Service
Due 25 January 2018
Resolved 25 January 2018
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 January 2018
Resolved
IN ADDITION TO THE REQUIREMENTS CONTAINED ELSEWHERE IN THE PRESENT REGULATIONS, SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION, OR WITH APPLICABLE NATIONAL STANDARDS OF THE ADMINISTRATION WHICH PROVIDE AN EQUIVALENT LEVEL OF SAFETY. PROVISIONS CRANE WAS IN USE DESPITE BEING PAST DATE WHICH REQUIRED CABLE TO BE RENEWED. CREW TAGGED OUT BREAKER SUPPLYING POWER TO CRANE. 74SOLAS(04)II-1/3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 February 2018
Resolution: Recieved class report attesting to the repair of the supply crane.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 January 2018
Resolved
Oil filtering equipment will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. during initial testing of the OWS, the three way valve did not actuate when oil content dropped below the set threshold. MARPOL (11) I/14.6
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2018