MAURY USCG vessel records
← All vessels

PRABHU NAND

PRABHU NAND is a 2008 tank ship. The Coast Guard has recorded 12 inspections since 2017, most recently in May 2024, along with 3 deficiencies.

Records from 2017 to 2024. Most recent: inspection, 23 May 2024.

Built
2008
Last inspected
23 May 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9425980
9V9126
990564
Flag
SINGAPORE
Maury page id
psix-990564

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 7 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it6436 - Convention (Subpart B), Net Ton
19997 - Dead Weight, Ton
25690 - Displacement, Ton
12099 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

23 May 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7917966
17 November 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826088
17 March 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7413456
6 December 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7107029
17 February 2020 ISPS Exam · PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6907137
19 February 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6628672
19 January 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6340435
7 January 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6333774
29 December 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6328741
24 April 2017 Bulk Liquid Transfer Monitor
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6132035
24 April 2017 Bulk Liquid Transfer Monitor
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6144125
31 January 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6080110

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 17 November 2023 Resolved
Each vessel connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeter (1 inch) long. It must be located at the top of the flange face, midway between boltholes, and in line with the bolthole pattern. PSCO observed that #1 aft and #2 forward Starboard vapor lines were missing the required stud.46CFR39.2001(j)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 May 2024
Resolution: Vessel provided photos of new studs on vapor lines.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 29 December 2017 Resolved
1910 - A tank from which a substance in category X has been unloaded shall be prewashed before the ship leaves the port of unloading. Appropriate entries of these operations shall be made in the Cargo Record Book and endorsed by the surveyor. Cargo tanks 9P and 9S unloaded Trimethyl Benzene, all isomers and category X cargo, on 17DEC17 at Kinder Morgan Deer Park in Houston, TX. A prewash was conducted but no survey was conducted by an authorized surveyor to verify the concentration of cargo in the tank washings. The tanks were subsequently washed at sea on 18DEC17 and loaded with acrylonitrile, a compatible category Y cargo on 23DEC17 (9S and 26DEC17 (9P). MARPOL II/13.6.1.1 74 SOLAS (14) IX/3.1 ISM Code Part A 7, 46 CFR 153.1120(a)(9) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2018
Resolved 7 January 2018
Resolution: Received flag report and company training confirming corrective actions.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 December 2017 Resolved
1860 - Each self propelled ship must have the following: Two stretchers or wire baskets complete with equipmentfor lifting an injured person from a pump room or a cargo tank. The stretcher in the ballast pump room was ripped and torn and would not be able to safely lift a person.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 January 2018
Resolved 19 January 2018
Resolution: Received corrective action report confirming receipt of new stretcher onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.