ROSSA is a 2007 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in April 2026, along with 5 deficiencies and 3 operational controls.
Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it29987 - Convention (Subpart B), Gross Ton 60643 - Displacement, Metric Ton 50633 - Dead Weight, Metric Ton 13240 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 1 January 2022Resolved
At least two independent means shall be provided for communicating order from the navigation bridge to the position in the machinery space. Appropriate means of communication shall be provided from the navigation bridge in the engine room to any other position from which the speed or direction may be controlled.
Engine Order Telegraph was report Non-operational during outbound transit. Rectify Deficiency Prior to Departure from the port to the satisfaction of the vessel Classification Society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 January 2022
Resolution: Recieved Dispensation for the related equipment.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 April 2020Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. The ODME sampling line between the overboard discharge line and the oil content meter had numerous wasted mounting brackets, with 10ft of piping unsupported.
MARPOL I/6.4.1
50 a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2020
Resolved 8 May 2020
Resolution: Received satisfactory class report.
0950-Electrical equipment in general-No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, unless Administration is satisfied of a type which will not ignite the mixture. PSCO noted emergency electric lights on main deck inoperative and improperly bonded. 74SOLAS(04)II-1/45.10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Grounding strap was replaced and all lights energized and burning brightly to the satisfaction of the PSCO.
0680-Enbarkation arrangement survival craft- An embarkation ladder shall be provided at each embarkation station. PSCO noted a single shackle mounting point, however the embarkation ladders were recently changed to a dual shackle mounting configuration, also chains fitted at forward embarkation station guardrails cannot be removed due to rusted release. 74SOLAS(14)III/11.7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Release mechanisms were free from rust and lubricated. Crew demonstrated operational test to the satisfaction of the PSCO.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 12 December 2016Resolved
0735-Personal equipment-Fire Fighting-Firefighting outfits or sets of person equipment shall be kept ready for use. PSCO noted 02 firefighting outfits in foam room which were deteriorated. 74SOLAS(09)II-2/10.3.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Invoice provided with proof of purchase for 02 firemans outfits to the satisfaction of the PSCO.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.