MAURY USCG vessel records Sign in
← All vessels

ROSSA

ROSSA is a 2007 tank ship. The Coast Guard has recorded 34 inspections since 2008, most recently in April 2026, along with 8 deficiencies and 5 operational controls.

Records from 2008 to 2026. Most recent: inspection, 27 April 2026.

Built
2007
Last inspected
27 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9391505 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
990608
Flag
BAHAMAS
—
Maury page id
psix-990608

Inspections, by type

…with no type recorded6
Years with a record 16 calendar years (2008–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29987 - Convention (Subpart B), Gross Ton
60643 - Displacement, Metric Ton
50633 - Dead Weight, Metric Ton
13240 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 34

27 April 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8356590
22 April 2026 PSC B · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8353888
24 May 2024 PSC B · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7918566
3 September 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7783246
30 August 2023 COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780951
29 August 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780220
29 June 2023 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7726158
6 April 2022 PSC B · COC-CHEM & TVE Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7425779
7 January 2022 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7377041
1 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7374340
20 April 2021 PSC B · COC-CHEM Annual · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7177058
4 September 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7050076
8 May 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6950325
16 April 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6935611
19 October 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6837712
11 September 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6809230
15 April 2019 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6660534
12 February 2019 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6624311
9 April 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6384471
15 July 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6209644
22 December 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6061340
8 December 2016 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6052852
22 November 2015 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5768509
16 October 2014 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5006062
29 August 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4966716
9 August 2011 ISPS I Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4110169
6 August 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4103396
30 November 2010 PII Safety Exam · COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3901158
7 May 2009 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3469626
2 April 2009 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3444794
24 March 2009 COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3439397
11 December 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3378294
9 December 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3376461
17 November 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3363041

Deficiency record · 8

10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 1 January 2022 Resolved
At least two independent means shall be provided for communicating order from the navigation bridge to the position in the machinery space. Appropriate means of communication shall be provided from the navigation bridge in the engine room to any other position from which the speed or direction may be controlled. Engine Order Telegraph was report Non-operational during outbound transit. Rectify Deficiency Prior to Departure from the port to the satisfaction of the vessel Classification Society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 January 2022
Resolution: Recieved Dispensation for the related equipment.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 April 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. The ODME sampling line between the overboard discharge line and the oil content meter had numerous wasted mounting brackets, with 10ft of piping unsupported. MARPOL I/6.4.1 50 a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2020
Resolved 8 May 2020
Resolution: Received satisfactory class report.
Electrical › Lighting (service) › Grounding Conductor
Issued 12 December 2016 Resolved
0950-Electrical equipment in general-No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, unless Administration is satisfied of a type which will not ignite the mixture. PSCO noted emergency electric lights on main deck inoperative and improperly bonded. 74SOLAS(04)II-1/45.10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Grounding strap was replaced and all lights energized and burning brightly to the satisfaction of the PSCO.
Lifesaving › Inflatable Liferafts › Boarding Ramp/Ladder
Issued 12 December 2016 Resolved
0680-Enbarkation arrangement survival craft- An embarkation ladder shall be provided at each embarkation station. PSCO noted a single shackle mounting point, however the embarkation ladders were recently changed to a dual shackle mounting configuration, also chains fitted at forward embarkation station guardrails cannot be removed due to rusted release. 74SOLAS(14)III/11.7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Release mechanisms were free from rust and lubricated. Crew demonstrated operational test to the satisfaction of the PSCO.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 12 December 2016 Resolved
0735-Personal equipment-Fire Fighting-Firefighting outfits or sets of person equipment shall be kept ready for use. PSCO noted 02 firefighting outfits in foam room which were deteriorated. 74SOLAS(09)II-2/10.3.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Invoice provided with proof of purchase for 02 firemans outfits to the satisfaction of the PSCO.
Lifesaving › Lifefloat › Serviceable
Issued 29 August 2014 Resolved
0610; Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. Rescue boat propeller an rudder damaged during previous operation during test. Crew unable to ensure adequate speed or maneuvering. See narrative for continuation of deficiency, 40A/C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2014
Resolved 10 October 2014
Resolution: Inspected, tested and repaired to the satisfaction of the attending Classification Representative.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 11 December 2008 Resolved
Due to the M/V VALROSSA main diesel engine automated controls being unavailable to place the vessel in astern, you are hereby restricted to a daylight transit only with a minimum two tug assist of appropriate horsepower, while entering the Port of Corpus Christi, TX. To the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2008
Resolution: Received class report (RINA) attesting to satisfactory operation of the automated controls.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 November 2008 Resolved
Circuit board in oil content meter of oil water separator has a malfunction, vessel has order spare part will be at New York which is the vessels next U.S. port. Prior to next operation of OWS provide class report attesting to proper system operation and function.
Action required: 705 - Other - as specified
Due 1 December 2008
Resolved 9 December 2008
Resolution: 09DEC2008 Conducted a PSC administrative Deficiency Check. Received a class report satisfying the requirement. Cleared 1 deficiencies from [Act#1234567, Sector San Juan, 12OCT2006]. 0 deficiencies remain outstanding. Agent:

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.