MAURY USCG vessel records
← All vessels

ROSSA

ROSSA is a 2007 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in April 2026, along with 5 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 27 April 2026.

Built
2007
Last inspected
27 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 April 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9391505
990608
Flag
BAHAMAS
Maury page id
psix-990608

Documentation record

Tonnage as PSIX records it29987 - Convention (Subpart B), Gross Ton
60643 - Displacement, Metric Ton
50633 - Dead Weight, Metric Ton
13240 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

27 April 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8356590
22 April 2026 PSC B · Administrative Inspection · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8353888
24 May 2024 PSC B · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7918566
3 September 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7783246
30 August 2023 COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780951
29 August 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780220
29 June 2023 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7726158
6 April 2022 PSC B · COC-CHEM & TVE Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7425779
7 January 2022 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7377041
1 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7374340
20 April 2021 PSC B · COC-CHEM Annual · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7177058
4 September 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7050076
8 May 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6950325
16 April 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6935611
19 October 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6837712
11 September 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6809230
15 April 2019 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6660534
12 February 2019 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6624311
9 April 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6384471
15 July 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6209644
22 December 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6061340
8 December 2016 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6052852

Deficiency record · 5

10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 1 January 2022 Resolved
At least two independent means shall be provided for communicating order from the navigation bridge to the position in the machinery space. Appropriate means of communication shall be provided from the navigation bridge in the engine room to any other position from which the speed or direction may be controlled. Engine Order Telegraph was report Non-operational during outbound transit. Rectify Deficiency Prior to Departure from the port to the satisfaction of the vessel Classification Society.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 January 2022
Resolution: Recieved Dispensation for the related equipment.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 April 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. The ODME sampling line between the overboard discharge line and the oil content meter had numerous wasted mounting brackets, with 10ft of piping unsupported. MARPOL I/6.4.1 50 a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2020
Resolved 8 May 2020
Resolution: Received satisfactory class report.
Electrical › Lighting (service) › Grounding Conductor
Issued 12 December 2016 Resolved
0950-Electrical equipment in general-No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, unless Administration is satisfied of a type which will not ignite the mixture. PSCO noted emergency electric lights on main deck inoperative and improperly bonded. 74SOLAS(04)II-1/45.10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Grounding strap was replaced and all lights energized and burning brightly to the satisfaction of the PSCO.
Lifesaving › Inflatable Liferafts › Boarding Ramp/Ladder
Issued 12 December 2016 Resolved
0680-Enbarkation arrangement survival craft- An embarkation ladder shall be provided at each embarkation station. PSCO noted a single shackle mounting point, however the embarkation ladders were recently changed to a dual shackle mounting configuration, also chains fitted at forward embarkation station guardrails cannot be removed due to rusted release. 74SOLAS(14)III/11.7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Release mechanisms were free from rust and lubricated. Crew demonstrated operational test to the satisfaction of the PSCO.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 12 December 2016 Resolved
0735-Personal equipment-Fire Fighting-Firefighting outfits or sets of person equipment shall be kept ready for use. PSCO noted 02 firefighting outfits in foam room which were deteriorated. 74SOLAS(09)II-2/10.3.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2017
Resolved 27 December 2016
Resolution: Invoice provided with proof of purchase for 02 firemans outfits to the satisfaction of the PSCO.

Ownership record